De-Icer - Meitav-tec

Download Report

Transcript De-Icer - Meitav-tec

PYRO-STAG
De-Icer Optimizer Controller
Technical presentation
2013
Introduction
Meitav-tec is introducing a new concept of De-Icing control
Featuring:
• Works with any existing De-Icing system
• Energy saving algorithm
• Simple and quick installation
• Simple, Logical & accessible user Interface
• Sequencing between zones allowing larger area coverage
with limited power supply
• Modularity – 1 to 4 contactors
CTU controller – PYRO-STAG
SYSTEM STRUCTURE
ANY
SNOW SENSOR
CONTROLLER
OUTPUT to
HEATERS
24VAC
supply
Outputs To 4 De-Icing
Heaters
Zone
1
Zone
4
Zone
2
Zone
3
System Features
• Steady power supply or Sequencing / Staggering between output zones
• Sequencing / Staggering - 1/2/3/4 or 1+3/2+4
• Adjustable Cycle time between zones
• Off Delay Time - Adjustable in cycles count
• Adjustable OFF Delay cycles
•Override operation – activates the system
CTU information
• 24VAC operated
• DIN RAIL or screws wall mounting
• Dimensions: 8 x 4 x 2 inches (205 x 96 x 60 mm)
Weight: 1 lb. (0.545 kg.)
• Flammability UL94V-0
• IP 20
Electric Layout
Operation Scenario # 1
• 4 zones works in staggering with OFF delay
Zones
1
2
De-Icer
ON input
INDEX:
Zone Output ON
Zone Output OFF
Input from De-Icer
3
4
1
2
3
4
Start
EndDelay
Of Delay
OFFTime
Time
Operation Scenario # 2
• 1 Zone works constantly
• 3 zones works in staggering
• OFF delay
Zones
1
2
De-Icer
ON input
INDEX:
Zone Output ON
Zone Output OFF
Input from De-Icer
3
4
1
2
3
Start
EndDelay
Of Delay
OFFTime
Time
4
Operation Scenario # 3
• 4 Zone works in staggering
• Every 2 zones are working together
• OFF delay
Zones
1
2
De-Icer
ON input
INDEX:
Zone Output ON
Zone Output OFF
Input from De-Icer
3
4
1
2
3
Start
EndDelay
Of Delay
OFFTime
Time
4
Configurations selection
• Simple DIP Switch positions define all options
• Easily modified by technician on site
ON
1
ON
2
3
4
5
6
7
8
1
2
3
4
• S1-1 - # of outputs work in staggering
- 2 or 4
• S1-2
- Outputs linkage
- outputs 1 & 3 and 2 &4 are linked or
outputs 1, 2, 3, 4 works separately
• S1-3+4+5
- Sequence step timer - 1, 5, 10, 20, 30, 45, 60, 120 min.
• S1-6
- Delay between outputs On/Off activation
• S1-7+8
- Off Delay # of cycles - 0, 1, 2, 3 delay cycles
• S2-1
- Device Enable/Disable - when disable = all outputs ON
Summary
• The Meitav-tec De-Icing Sequence device offers solution for
installations with large power consumption as it allows to
divide power supply to separate zones
• The PYRO_STAG controller can be used with any existing DeIcing system
• Simple installation and easy configuration will minimize cost
• Energy saving algorithm staggering between zones allows
large area coverage with lower power consumption
• Professional Service and JIT availability