Genesys™ Manifolds - Tri

Download Report

Transcript Genesys™ Manifolds - Tri

Genesys™ Manifolds
Designed for today & tomorrow
Genesys™ Manifolds
What makes Genesys™ manifolds unique and better
than other brands?
Tri-Tech








Field upgradeable (low to high flow)
Field convertible (delivery pressure)
Field convertible (from cyl to liq)
Triggers high/low line pressure,
emergency reserve in use, and
emergency reserve low master alarm
signals using transducers & logic board
(not pressure switches)
Unique efficient low watt heater
Custom design solenoid – will not lock
up
Economizer software
Built-in DISS gas specific emergency
feed ports
Other brands





Not field upgradeable and not field
convertible
For high/low pressure, emergency
reserve in us, and emergency reserve
low signals to Master Alarm, must
supply separate pressure switches
apart from manifold, and signals do
not come through the manifold
High watt heater
Shuttle Valve can lock up, requires
annual inspection, and gas supply must
be completely shut off to replace or
service.
No economizer software
Genesys™ Manifolds




Field upgradeable –
flow rates
Standard flow – up to
2,500 scfh
High flow – up to 4,500
scfh
This cannot be done
with other manifolds
Genesys™ Manifolds





Field convertible –
delivery pressure
50 psi, 80 psi or 180 psi
Cyl x cyl or liq x liq
Six sets of logic – built
into the circuit board
This cannot be done
with other manifolds
Genesys™ Manifolds


Cylinder x cylinder inlet
blocks, bank pressure
transducers & primary
regulators
Easy to service
Genesys™ Manifolds


Liquid x liquid inlet
blocks, left & right bank
transducers & solenoids
Easy to service
Genesys™ Manifolds







Triggers all 5 NFPA
required master alarms
via transducers & logic
board
High line pressure
Low line pressure
Secondary in use
Emergency reserve in use
Emergency reserve low
Other brands do not do
that – they only provide
Secondary in Use
Genesys™ Manifolds




Triggers high & low
line pressure alarms
with transducers & logic
board
Immediate alarm if a
transducer fails vs no
alarm if pressure switch
fails
More accurate
Other brands do not
provide these
Genesys™ Manifolds

Custom design solenoid – will
not lock up due to pressure
differential

Exceeds 400 psig differential rating
Normally open (must be energized
to close)

Shuttle valves CAN lock up and CAN
prevent changeover. It does not operate
well in low flow applications. It
requires annual inspection. In order to
service the shuttle valve, gas
supply/manifold must be shut down.
Genesys™ Manifolds




Unique low wattage
heater design
N2O & CO2
applications
Prevents possible
primary regulator
freeze-up
Other brands do not
provide this
Genesys™ Manifolds


Bank status indicators
In Use
Ready
Empty
Pressure indicators
Supply
Left Bank
Right Bank
Intermediate
High pressure reserve
Genesys™ Manifolds



Economizer
hardware
Economizer
software
Other brands do
not provide this
We’ve come a long way …..