Transcript Slide 1

PSS Merlin
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/1
SELF CONTAINED BREATHING APPARATUS
BODYGUARD II
Combines these safety features in one device:
● Digital Pressure reading
● ‘Time To Whistle’ based on actual consumption rate
● Integrated ADSU / PASS
● Manual Distress Signal Alarm
● Temperature Display
● Electronic acoustic and optical low pressure warnings
● 2nd Independent pneumatic low pressure warning
● Flexible parameter setting with Windows software
● Data logging
● Telemetry ready IR Communications port
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/2
SELF CONTAINED BREATHING APPARATUS
BODYGUARD II FEATURES
LCD Display
LH button to
illuminate
RH button to
display
temperature
Manual Distress
Button
Warning LEDs
Pneumatic
Whistle
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/3
SELF CONTAINED BREATHING APPARATUS
BODYGUARD II DISPLAY
Digital Cylinder
Pressure
Time To Whistle
(TTW)
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/4
Clock Icon
indicates time
SELF CONTAINED BREATHING APPARATUS
BODYGUARD IR LINK II SOFTWARE – DATA LOG/PARAMETER MAINTENANCE
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/5
SELF CONTAINED BREATHING APPARATUS
BODYGUARD IR LINK II SOFTWARE – ENHANCED DATALOG GRAPHIC
Select events to be displayed on graph
Graphs can also be
produced for analysis
with many new options
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/6
SELF CONTAINED BREATHING APPARATUS
PSS MERLIN - TELEMETRY
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/7
SELF CONTAINED BREATHING APPARATUS
PSS MERLIN - TELEMETRY
Telemetry - What does it provide now?
1. Continuous transmission of Pressure, Time
Remaining , Temperature , battery status, etc
2. Two way evacuation/withdrawal signalling with
acknowledgements
3. ADSU alarms and manual distress signals
Which means vital safety data displayed at the Control Board !
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/8
SELF CONTAINED BREATHING APPARATUS
PSS MERLIN – ECB DISPLAY
Each logged on Fire Fighter permanently displayed on ECB - No Scrolling!
Display window
Evacuation button
- customer preference e.g. TTW
‘On Line’ signal indicator
Time to Whistle
Display at Bodyguard
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/9
SELF CONTAINED BREATHING APPARATUS
PSS MERLIN – “I“ BUTTON OPTIONS
Time of Whistle
Display reverts to default selection after x secs
‘information’ button
Pressure
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/10
Time to Whistle
Temperature
Time Elapsed
SELF CONTAINED BREATHING APPARATUS
PSS MERLIN – TELEMETRY DATA LOGGING
Date
Time
Channel Brigade ID Portable
Unit ID
21/07/2002
11:17:19
2
13
1
21/07/2002
11:17:29
1
13
2
21/07/2002
11:17:29
1
13
2
21/07/2002
11:17:30
1
13
2
21/07/2002
11:17:30
1
13
2
21/07/2002
11:17:30
1
13
2
21/07/2002
11:17:33
2
13
1
21/07/2002
11:17:33
2
13
1
21/07/2002
11:17:38
2
13
1
21/07/2002
11:17:54
2
13
1
21/07/2002
11:17:54
2
13
1
21/07/2002
11:17:55
2
13
1
21/07/2002
11:17:55
2
13
1
21/07/2002
11:17:55
2
13
1
21/07/2002
11:17:55
-------21/07/2002
11:22:10
-------21/07/2002
11:22:11
7
13
1
21/07/2002
11:22:11
7
13
1
21/07/2002
11:22:11
-------21/07/2002
11:22:11
7
13
1
21/07/2002
11:22:11
7
13
1
21/07/2002
11:22:13
7
13
1
21/07/2002
11:22:14
7
13
1
21/07/2002
11:22:35
7
13
1
21/07/2002
11:22:55
7
13
1
21/07/2002
11:23:16
7
13
1
21/07/2002
11:23:33
7
13
1
21/07/2002
11:23:33
7
13
1
21/07/2002
11:23:33
7
13
1
21/07/2002
11:23:42
7
13
1
21/07/2002
11:23:42
7
13
1
21/07/2002
11:23:43
7
13
1
21/07/2002
11:23:53
7
13
1
21/07/2002
11:23:58
7
13
1
DRÄGER
SAFETY
• TELEMETRY
21/07/2002
11:23:58
7
13
1
MAY
2007 • 1/11
21/07/2002
11:23:59
7
13
1
21/07/2002
11:24:13
7
13
1
Event
PU Data
PU Data
ECB tx - Logoff Req
PU Data
ECB tx - Logoff Ack
PU Event Logged Off
PU Data
PU Data
Tally out
PU Data
ECB tx - Logoff Req
PU Data
ECB tx - Logoff Ack
PU Event Logged Off
ECB Sleep
Error 84 Radio fail Set
Tally in
ECB tx - Logon request
Error 04 Radio fail Cleared
Logged on
ECB tx - Logon Ack
PU Data
PU Data
PU Data
PU Data
PU Data
PU Data
PU Event WDRAW signal tripped
PU Data
PU Event WDRAW signal acknowledged at ECB
ECB tx - Withdraw Ack
PU Data
PU Data
PU Event EVAC started at ECB
ECB tx - Evac
PU Data
PU Event EVAC acknowleged at PU
Press
TTW
Temp
Whistle/ Time to
Low Batt Log on
175.75
0
20
0
18
18 Whist:
0
0
18 Whist:
18.25
18.25
0
0
18 Whist:
18 Whist:
0
0
18 Whist:
0
0
18 Whist:
Cyl
Size (L)
Press
Rating
WWU
Setting
Datalog Windows Software and
data link cable
173.75
3
177
176.75
176
175.37
174.88
174.63
20
20
20
20
19
19
18
18
18
20
20
20
174.63
19
20
174.5
174.63
19
19
20
20
174.37
19
20
6.75
300
56
SELF CONTAINED BREATHING APPARATUS
PSS MERLIN – BA ENTRY CONTROL
Safety of Firefighters !
•
•
•
•
•
•
•
Disciplined donning and pre-entry checks
Accountability of Firefighters via Entry Control Board
Pressure, time in, personal details on tally
Maintenance of Team and location data
Calculate initial Time To Whistle
Relieve teams prior to whistle
Control of Emergency rescue teams
Entry Control Officer with control board
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/12
SELF CONTAINED BREATHING APPARATUS
PSS MERLIN – BA ENTRY CONTROL
Current information shortfall!
Merlin Delivers
•
•
•
•
•
•
•
•
•
•
•
•
1. Time to whistle based on initial pressure
2. Assumes fixed breathing rate of 40 Ltr /min
3. No continual monitoring of pressure by ECO
4. No awareness of distress signals
5. No evacuation / withdrawal signal protocol
6. No automatic comprehensive evidential record
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/13
Monitoring of TTW and Display Time of Whistle
Calculates Breathing Rate
Displays pressure on demand
Monitors Distress Signals
Evacuation Signals/ Monitor Withdrawal Signals
Electronic Data logging
SELF CONTAINED BREATHING APPARATUS
PSS MERLIN - TELEMETRY
Telemetry - What will it provide in the future?
1. Physiological Monitoring of core body
temperature, pulse, etc
2. Environmental monitoring of ambient
3. Alarms based on environmental and physiological
measurements
4. Location?
5. Speech?
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/14
PSS MERLIN WORKSHOP
COMMISSIONING EXPLAINED
“I“ BUTTON DISPLAY OPTIONS
1.Time of whistle (Bodyguard)
2.Time to whistle (Bodyguard)
Factory Settings
3.Pressure
4.Temperature
5.Elapsed time since log on
•Radio low battery status
•Time of whistle static (TB1/97 initial pressure + fixed breathing rate)
•Time of whistle dynamic (Bodyguard pressure + fixed breathing rate)
•Display flashing ‘x’ mins to whistle (factory default 10 mins)
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/15
PSS MERLIN
ENTRY CONTROL ACCESSORIES
ECB Bracket
Entry Control Board
3351803
3351145/3351616
Tripod
3351802
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/16
PSS MERLIN
ENTRY CONTROL ACCESSORIES
Manual Operation :
Digital Clock
3351903
ECB Cover PVC
3351812
+
= TB 1/1997 
Duration Tables
Chinagraph pencil
3351237
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/17
3351845/46/47
PSS MERLIN
BATTERY CHARGING FLEXIBILITY
Power Cords
3351805/6/7
4 Way Portable Unit Charger
Power Supply
3351815
3351804
Vehicle Clip Charger
3351681
ECB Workshop Charger Kit
3351819
ECB Vehicle Charger
3351810
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/18
THANK YOU FOR YOUR ATTENTION!
DRÄGER SAFETY • TELEMETRY
MAY 2007 • 1/19