Transcript Slide 1
Building Metering & Benchmarking: It’s Worth the Energy American University Emily Curley, Sustainability Coordinator Chris O’Brien, Director of Sustainability April 16, 2013 AU Office of Sustainability: Staff 2 AU Office of Sustainability: Vision Strategic Plan Goal #7: “Act on our values through social responsibility and … an active pursuit of sustainability...” 3 Driving Frameworks ACUPCC LEED STARS Carbon Neutral by 2020 Certify 25 Existing Buildings Achieve a Platinum Rating Mayor’s College & University Sustainability Pledge Comprehensive Sustainability Plan 4 Climate Action Plan Reduce Consumption Produce Renewable Energy on Campus Purchase Renewable Energy Purchase Offsets 5 AU Greenhouse Gas Emissions 70,000 60,000 50,000 Total Emissions Net Emissions Purchased Electricity 40,000 Study Abroad Air Travel Natural Gas MTCO2e 30,000 Faculty / Staff Commuting Directly Financed Air Travel 20,000 Student Commuting Scope 2 T&D Losses Direct Transportation 10,000 Paper Purchasing Refrigerants & Chemicals 0 2005 2006 2007 2008 2009 2010 2011 2012 Solid Waste Agriculture -10,000 Campus Trees RECs -20,000 -30,000 6 Benefits of Increasing Energy Savings Comply with DC Green Building Act Reduce utility costs (electric, gas, water, chemical) Reduce operations & maintenance (labor, equipment) Reduce reliance on RECs and Offsets Fulfill Presidents Climate Commitment Improve occupant comfort Earn LEED recognition 7 LEED Checklist – Existing Buildings LEED 2009 for Existing Buildings: Operations & Maintenance Project Name Projec t Chec klist Sustainable Sites Y ? Date Possible Points: 26 Materials and Resources, Continued N Y Credit 1 Credit 2 Credit 3 Credit 4 Credit 5 Credit 6 Credit 7.1 Credit 7.2 Credit 8 LEED Certified Design and Construction 4 Building Exterior and Hardscape Management Plan 1 I ntegrated Pest Mgmt, Erosion Control, and Landscape Mgmt Plan 1 Alternative Commuting Transportation 3 to 15 Site Development—Protect or Restore Open Habitat 1 Stormwater Quantity Control 1 Heat I sland Reduction—Non-Roof 1 Heat I sland Reduction—Roof 1 Light Pollution Reduction 1 Water Efficiency Possible Points: 14 ? N Credit 6 Credit 7 Credit 8 Credit 9 Prereq 1 Credit 1 Credit 2 Credit 3 Credit 4 Minimum I ndoor Plumbing Fixture and Fitting Efficiency Water Performance Measurement Additional I ndoor Plumbing Fixture and Fitting Efficiency Water Efficient Landscaping Cooling Tower Water Management Y Y Y Prereq 1 Prereq 2 Prereq 3 Credit 1.1 Credit 1.3 1 1 1 1 to to to to 2 5 5 2 Credit 1.4 Credit 1.5 Credit 2.1 Credit 2.2 Credit 2.3 Energy and Atmosphere Possible Points: 35 Credit 2.4 Credit 3.1 Y Y Y Prereq 1 Prereq 2 Prereq 3 Credit 1 Credit 2.1 Credit 2.2 Credit 2.3 Credit 3.1 Credit 3.2 Credit 4 Credit 5 Credit 6 Energy Efficiency Best Management Practices Minimum Energy Efficiency Performance Fundamental Refrigerant Management Optimize Energy Efficiency Performance Existing Building Commissioning—I nvestigation and Analysis Existing Building Commissioning—I mplementation Existing Building Commissioning—Ongoing Commissioning Performance Measurement—Building Automation System Performance Measurement—System-Level Metering On-site and Off-site Renewable Energy Enhanced Refrigerant Management Emissions Reduction Reporting Credit 3.2 Credit 3.3 Credit 3.4 1 to 18 2 2 2 1 1 to 2 1 to 6 1 1 Credit 3.5 Credit 3.6 Y Y Prereq 1 Prereq 2 Credit 1 Credit 2.1 Credit 2.2 Credit 3 Credit 4 Credit 5 Possible Points: Sustainable Purchasing Policy Solid Waste Management Policy Sustainable Purchasing—Ongoing Consumables Sustainable Purchasing—Electric Sustainable Purchasing—Furniture Sustainable Purchasing—Facility Alterations and Additions Sustainable Purchasing—Reduced Mercury in Lamps Sustainable Purchasing—Food C er t i f i ed 4 0 t o 4 9 p o i nt s 10 Management—Waste Stream Audit Management—Ongoing Consumables Management—Durable Goods Management—Facility Alterations and Additions Credit 1.1 Credit 1.2 Credit 1.3 Credit 1.4 Credit 3 Si l ver 50 t o 59 p o i nt s Credit 1.1 Credit 1.2 Credit 1.3 Credit 1.4 15 1 1 I AQ Best Mgmt Practices—Outdoor I AQ Best Mgmt Practices—I ncreased Ventilation 1 I AQ Best Mgmt Practices—Reduce Particulates in Air Distribution1 I AQ Mgmt Plan—I AQ Mgmt for Facility Alterations and Additions 1 Occupant Comfort—Occupant Survey 1 Controllability of Systems—Lighting 1 Occupant Comfort—Thermal Comfort Monitoring 1 Daylight and Views 1 Green Cleaning—High Performance Cleaning Program 1 Green Cleaning—Custodial Effectiveness Assessment 1 Green Cleaning—Sustainable Cleaning Products, Materials Purchases 1 Green Cleaning—Sustainable Cleaning Equipment 1 Green Cleaning—I ndoor Chemical and Pollutant Source Control 1 Green Cleaning—I ndoor I ntegrated Pest Management 1 Possible Points: I nnovation in Operations: Specific Title I nnovation in Operations: Specific Title I nnovation in Operations: Specific Title I nnovation in Operations: Specific Title LEED Accredited Professional Documenting Sustainable Building Cost I mpacts Regional Priority Credits 1 1 1 1 1 1 Possible Points: 1 1 1 1 Minimum I AQ Performance Environmental Tobacco Smoke (ETS) Control Green Cleaning Policy I AQ Best Mgmt Practices—I AQ Management Program Innovation in Operations Credit 2 Materials and Resources Waste Waste Waste Waste Indoor Environmental Quality Credit 1.2 Y Solid Solid Solid Solid Regional Priority: Regional Priority: Regional Priority: Regional Priority: Specific Specific Specific Specific Total G o l d 6 0 t o 79 p o i nt s Possible Points: Credit Credit Credit Credit 1 1 1 1 1 1 4 1 1 1 1 Possible Points: Pl at i num 8 0 t o 110 6 110 Energy Efficiency & Occupant Comfort Studies1 show that Energy Star rated & LEED certified buildings: Increase productivity by 1%-5% Increase employee morale Reduce turnover Improve recruitment Reduce allergic reactions and stress 1 CBRE & University of San Diego, 2009; McGraw-Hill, 2009; Michigan State, 2009; http://www.institutebe.com/Existing-Building-Retrofits/Productivity-Gains-from-Energy-Efficiency.aspx 9 Energy Saving Strategies Install meters 25 ASHRAE level I audits $1.2m energy-saving projects complete Library Lighting Butler Tunnel Lighting Arena Lighting ASHRAE level II audits: Bender Library, Katzen, MGC, Sports Center, Ward Circle 10 Case Study: Bender Library 117,940 gsf with electricity, district steam & chilled water, solar PV 5th largest energy using building on campus 11 Case Study: Bender Library Results not so encouraging… LEED requires ENERGY STAR score of 19 or source EUI 19% better than national average Total kBtu Current Usage (12 months ending June 2012) 18,327,876 LEED Prerequisite 9,895,166 Savings Needed to Meet Prerequisite (kBtu) 8,432,710 Savings Needed to Meet Prerequisite (%) Site EUI (kBtu/sf) Source EUI (kBtu/sf) 155.4 357.3 83.9 193 46% 12 Bender Library Energy Savings ASHRAE Level II Audit Identified ECMs: Project Annual kBtu Savings Cost Annual Savings Simple Payback (years) Install VFDs for 40% Minimum Airflow 6,303,804 $390,850 $ 83,165 4.7 Demand controlled ventilation w/CO2 sensors 2,838,079 $29,600 $ 10,455 2.8 286,042 $39,370 $ 8,554 4.6 Occupancy Sensors in Offices 14,704 $11,800 $ 1,900 6.2 Lighting Setback, Unoccupied Times 14,591 $10,725 $ 4,467 2.4 $482,345 $ 123,560 3.9 Replace AHU-3 with a VAV System All ECMs Combined* % of current energy use 8,241,456 45% *Simply summing all the savings for each measure would not accurately represent the savings that would be seen if all measures were implemented. 13 Bender Library Performance After Have since completed relighting/delamping project in Library for additional low-cost savings On target to meet prerequisite pending improvements Total kBtu Current Usage (12 months ending June 2012) LEED Prerequisite Savings identified in audit New total % savings still needed Site EUI (kBtu/sf) Source EUI (kBtu/sf) 18,327,876 155.4 357.3 9,895,166 8,241,456 83.9 193 10,086,420 85.5 196.6 2% 14 Case Study: Katzen Arts Center 3rd largest energy using building on campus 335,476 gsf with electricity, natural gas, solar PV Large parking garage = 60% of total area Museum and performance space = 20% Art “lab” space = 10% 15 Case Study: Katzen Arts Center Special case for LEED given difficulty of comparison with other buildings LEED requires source EUI 19% better than 3 year historical baseline average Total (kBtu/year) Site EUI (kBtu/sf) Current usage (12 months ending 12/12) 27,854,037 224.7 456.1 LEED Prerequisite 23,017,416 186 382 Savings Needed to Meet Prerequisite (kBtu) 4,836,621 17% Savings Needed to Meet Prerequisite (%) Source EUI (kBtu/sf) 16 Katzen Energy Savings ASHRAE Level II Audit Identified ECMs: Project Annual kBtu Savings Cost Annual Savings Simple Payback Free Cooling w/ Plate & Frame Heat Exchanger 273,523 $163,846 $11,958 8.4 Variable Primary Chilled Water Pumping 500,001 $87,113 $21,882 4.0 Ice Storage 321,025 $160,810 $23,989 6.7 1,742,191 $123,520 $17,074 7.6 76,501 $5,500 $3,475 2.4 927,511 $5,500 $23,785 0.2 Rebalance to Lower Airflows 1,991,757 $28,000 $48,421 0.6 Solar Thermal Heating Water 1,474,150 $104,310 $15,626 6.7 67,151 $29,260 $8,555 3.4 5,549,703 $707,859 $131,908 5.4 Summertime Condensing Boiler Chilled Water Temperature Reset Supply Air Fan Static Pressure Reset Daylighting All ECMs Combined* % of current energy use 19.9% *Simply summing all the savings for each measure would not accurately represent the savings that would be seen if all measures were implemented. 17 Katzen Art Center Performance After Identified ECMs together reduce consumption to LEED prerequisite level Katzen would qualify for 1 additional LEED point with new total Total kBtu Site EUI (kBtu/sf) Source EUI (kBtu/sf) Current usage (12 months ending 12/12) 27,854,037 224.7 456.1 LEED Prerequisite 186 382 Savings identified in audit 23,017,416 5,549,703 New total 22,304,334 180 365 18 Target Campus Energy Use* Annual Energy Use Targets 250,000 228,793 LEED compliance level = 69th percentile 200,000 178,930 161,839 150,000 MMBTU 134,443 104,434 100,000 97,823 50,000 0 Fiscal Year 2013 2014 2015 2016 2017 2018 * 25 targeted existing buildings. 19 Target Annual Cost Savings1 Annual Projected Cost Savings $3,000,000 $2,428,635 $2,500,000 $2,281,082 $2,000,000 $1,521,314 $1,500,000 $896,077 $1,000,000 $500,000 $240,863 2 $- Fiscal Year 2014 2015 2016 2017 2018 125 targeted existing buildings. savings in proportion to current electric/gas consumption (56% electric/44% gas). Total savings range is based on splitting savings from 33% electric & 67% gas, to 67% electric & 33% gas. 2Assumes 20 Financing Options 1. Invest $8-$10M, 8-10 yr payback a. $3.3M/yr for 3 yrs b. Increase energy project funding from $700k/yr to $1.7/yr for 6 years i. Consider revolving fund 2. Third Party Financing – $0 cost to AU but cost savings are minimized 21 Next Steps - RFQ for energy conservation measures - Determine financing & contracting approach - RFPs for design & construction - Finalize contracts & financing - Implement projects 22 Lessons Learned Building-level metering is teaching us which buildings consume the most energy and cost the most to operate Energy benchmarking is teaching us which buildings are the most inefficient relative to buildings like it Energy auditing is teaching us that making investments in energy efficiency are often financially prudent and allow us to meet our environmental goals 23 Thank you! [email protected] www.american.edu/sustainability Twitter.com/GreenAU facebook.com/GreenAU 24