Open chamber RBC 24 E
24 kW
Self diagnostic system Electronic thermometer Furnace type: open Output power: 22,66 kW Min. 6,7 kW Stars of efficiency: * Expansion vessel: 6 lt.
Flow rate raised t 30°: 11,20 lt/min Width: 410mm Height: 730mm Depth: 320mm
Mini 24
Wall-hung boiler Bithermic exchanger
Sealed chamber RBS 24 E
24 kW
Self diagnostic system Electronic thermometer Furnace type: sealed Output power: 23,45 kW Min. 6,7 kW Stars of efficiency: *** Expansion vessel: 6 lt.
Flow rate raised t 30°: 11,42 lt/min Width: 410mm Height: 730mm Depth: 320mm
RBS 24
Wall-hung boiler Bithermic exchanger
Sealed chamber Open chamber RBC 24
Component list Mini RBC 24 – RBS 24 1.
2.
3.
4.
5.
6.
Bithermic heat exchanger Atmosferic burner Ignition electrode Flame sensing electrode Safety heating thermostat Electronic gas valve 7.
8.
9.
Expansion vessel Circulating pump Automatic air vent 10.
3 bar central heating safety valve 11.
System pressure gauge 12.
Water gauge 13.
Water pressure switch 14.
Central heating thermostat control 15.
Domestic hot water thermostat control 16.
Flow rate control 17.
Electronic DHW flow rate 18.
By-pass (optional) 19.
Air pressure switch 20.
Fan
MINICODE ® Electronic panel SM 30001
Controls
1. On-off 2. CH temp.control 30-80 °C 3. DHW temp.control. 35-65 °C 4. Electronic thermometer Self diagnostic system With flash light 5. CH and DHW sonde 6. Safety thermostat 7. No ignition (Cut off) 8. Exhaust safety thermostat Air pressure switch 9. No water into CH implant 10. On
MINICODE ® Electronic panel SM 30001 • • • • • • • • • • • • • • Characteristics Self diagnostic system Continuous flame modulation in CH - DHW DHW temperature from 35 ° to 65°C CH temperature from 30 ° to 80°C Max power regulation Low CH temperature Antifrost system Post circulation pump No block pump safety Late starting (for little implant) Outside temperature Automatic by-pass (optional) Remote control system (optional) IP X5D
1 2 3 4
MINICODE ® Electronic panel SM 30001
Selector
1. Switch for max heating power “MAXR” 2. Switch for the min power “MIN” 3. Switch for step starting power “RLA” 4. Switch for 15 min. max power “SPAZ”
MINICODE ® Electronic control SM 30001 A CH temperature selection B CH temporized (3 minutes) C DHW no over pressure D E F DHW temperature selection Monothermic – Storage- Bithermic System – combi – storage boiler G Natural gas LPG
Gas valve NORDGAS
Gas valve
• • • • • Motorized valve Ignition transformer separated Simple regulation Quiet work More sensibility, quick work
Electronic flow control Radiant
Radiant electronic flow control
• Flow control with microprocessor, on from 0,2 bar • Limescale protection • Stainless steel filter • Water rate control
Burner 12 ramps
12 ramps burner
• Multigas burner • Very simple change mode:natural gas LPG • High efficiency • Quiet mode • Ionization flame control with electrode
Exchanger Bithermic
Bithermic exchanger
• Limescale control with NTC sondes • 6 thermic exchange passages
No weld point Bithermic exchanger Radiant
Bithermic exchanger
Domestic Hot Water Central Heating Water
Case
Unsoundtrack
Front and side insulating panel, for a lower noice level of working
Exhaust control
Exhaust control
In the duct connection is present a disc where two holes does a simple mode of exhaust control
Dimensions
Optional
Optional accessories
Thermostat with mechanical clock Remote LCD control Outside temperature sonde
The future now with