Diapositiva 1 - Royal Institute of Technology
Download
Report
Transcript Diapositiva 1 - Royal Institute of Technology
L. Mansani
[email protected]
WP1.2
EFIT and XP-ADS Data
1
EUROTRANS: WP1.5 Technical meeting, Bologna, May 28-29, 2008
Reference Documents
EFIT
D1.24 Main Component Functional Sizing of the EFIT (under review
to make consistent with D1.26 and to include primary system
pressure losses, Lead volume, primary and target pumps
characteristics, DHR 1 & DHR 2, CFX evaluation, etc)
D1.26 Main Component Assembly Drawings of EFIT (issued)
XT-ADS
D1.27 & D1.28 Description and functional sizing of the Main
Components of the Reference Design of the XT-ADS (Draft)
Main Component Assembly Drawings of EFIT (Draft)
2
EUROTRANS: WP1.5 Technical meeting, Bologna, May 28-29, 2008
p 0.5 v2
+1985
Primary coolant flow rates
[Kg/s]
total:
36000
across the core
- fuel assemblies:
33000
- fuel assemblies by-pass:
650
- dummy assemblies:
550
across the HX of the Target Unit: 1500
+1085
ΔPsg
P- head
1.37 bar
SG
SGU Midplane -1655
across each pump:
across each SG:
ΔPsg + ΔPc = P-head – ΔPp
+1473
9000
4500
ΔPc: fuel assemblies pressure drop
ΔPp: pump duct pressure drop, with
pump working
ΔPsg: SG pressure drop
P-head: head of the pump
ΔPsg
0.4 bar
mfr
4500 kg/s
ΔPp
0.27 bar
mfr
9000
kg/s
Core Midplane -5355
+406
Pump ΔPp= 0.5 ξρv2
ξ=2.2 pump in operation
ξ=3.7 pump free
ξ= 5.6 pump locked
ΔPc = 0.7bar
mfr = 33000 kg/s
ΔPc-in = 0.3 bar
ΔPc-out = 0.1 bar
ΔP-rods = 0.2bar
ΔPc-grids = 0.1 bar
Pressure Drops and Free Levels
in the EFIT Primary System
3
EUROTRANS: WP1.5 Technical meeting, Bologna, May 28-29, 2008
+1985
+1473
+1085
M = 589 tons
(8 SGs & 4 PPs)
SG
v = 0.6 m/s
Total Mass of Lead = 5954 tons
Pump duct
v = 1.5 m/s
DHR M = 174 t
DHR
v = 0.15 m/s
+406
M = 855 tons
M = 3596 tons
M = 570 tons
Core
v = 1 m/s
Lead Mass Distribution and Average
Velocities in the EFIT Primary System
M = 170 tons
4
EUROTRANS: WP1.5 Technical meeting, Bologna, May 28-29, 2008
EFIT Primary Pump Characteristic
3
2.5
n= 200 rpm
Head [m]
2
1.5
1
0.5
2000
3000
4000
5000
6000
7000
8000
9000
10000 11000 12000 13000 14000
Mass flow rate [kg/s]
5
EUROTRANS: WP1.5 Technical meeting, Bologna, May 28-29, 2008
XT- ADS General Arrangement
6
EUROTRANS: WP1.5 Technical meeting, Bologna, May 28-29, 2008
XT- ADS General Arrangement
7
EUROTRANS: WP1.5 Technical meeting, Bologna, May 28-29, 2008
XT- ADS Primary Heat Exchanger
8
EUROTRANS: WP1.5 Technical meeting, Bologna, May 28-29, 2008
900
Mass Flow Rate,
Pressure Drops and
Free Levels In the
XT-ADS Primary
System
Mid Point
PHX
PHX (N° 4)
mfr/PHX: 1750 kg/s
ΔPPHX = 25000 Pa
v = 1 m/s
Core Pressure Drop
Mass flow rate: 4518 kg/s
Pressure drop: 90900 Pa
Core v = 1.5 m/s
Core Mass Flow Rates
Fuel A:
4518 kg/s
By Pass: 296 kg/s
Dummy A: 1258 kg/s
Target:
206 kg/s
Storage F: 90 kg/s
Others:
631 kg/s
2000
Data for primary
system design
Mid Point
Fuel
Pump (N° 2)
mfr/pump: 3500 kg/s
ΔPpump:
47000 Pa
Pump duct v = 1.9 m/s
Δppump = 0.5 ξ ρ v2
ξ= 2.5 pump working
ξ= 3.3 pump not locked
ξ= 4.8 pump locked
9
EUROTRANS: WP1.5 Technical meeting, Bologna, May 28-29, 2008
XT- ADS Primary Pump Characteristic
3
2.5
n=350 rpm
Pump Head [m]
2
Best efficiency point
1.5
1
0.5
0
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
Mass Flow Rate [kg/s]
10