Input function extraction
Download
Report
Transcript Input function extraction
EXTRACTING ARTERIAL BLOOD
CURVE FROM PET IMAGE
Images containing abdominal aorta
why
missing blood data
noninvasive alternative
high costs of arterial sampling
other problems with arterial sampling
more reliable than arterialised venous sampling
method - what are we fitting
only once
diameter of the vessel (needs initial value)
for all frames separately
center of the vessel
activity inside vessel
activity of the surrounding area
how
Known:
K
CI=activity in PET image
Unknown:
CB=final input TAC
CBG=background activity
CA=activity inside arteria
CI=(CA-CBG)*K+CBG
=>
1
CB
1 e
* CA
R2
FWHM
2*
2.355
2
distance from the centre
of vessel
Adipose tissue study
problems & ideas
results are very dependent on diameter value
2D convolution might be used for testing
References
Germano et al.: Use of Abdominal Aorta for
Arterial Input Function Determination in
Hepatic and Renal PET Studies: J Nucl Med
1992; 33:613-620