Transcript Slide 1

Product Overview
ACCESS DEVICES
Ports
Bladeless
Pyramidal
Shielded
Hasson
THREADED CANNULAE
Rotate Clockwise to
Insert
Rotate Counter-Clockwise to
Remove
 Beveled and Angled Distal TipFor less insertion force and
better visualization
 CO2 Port
 45° angle to reduce CO2
tubing kinking
 Slide Valve
 Located on winged handle
 Red – Closed
 Green – Open
 70 / 100 lengths
Threaded Cannulae
Smooth Cannulae
Beveled and Angled Distal Tip - For less
insertion force and better visualization
 Clear – for easy specimen retrieval
 CO2 Port
 45° angle to reduce CO2 tubing
kinking
Slide Valve
Located on winged handle
Red – Closed
Green – Open
Available sizes
5mm,7/8mm, 10mm, 12mm, 15mm
 Sizes are stamped on Cannula
Body
Available lengths
70mm, 100mm,150mm

BLADELESS TROCARS
Bladeless Tip Trocar
 Allows for visualization during
insertion
 Distinctive engineered visual tip
 Separates and dissects
abdominal wall
 Available sizes
 -5mm
 -7/8 mm
 -10mm
 -12mm
 -15mm
 Available length
 70mm, 100mm 150mm
Unique Features
• Smaller wound defect size than most trocar
products
• Less insertion force
• Less incidence of internal injuries
• Greater visualization of tissue layers
w/scope use
• Separates and dissects abdominal wall
• Smooth insertion reducing pre- peritoneal
tenting
• Less insertion force
• Ergonomic handle – easy grip for insertion
• Scope seal 5– 10mm
Bladeless Trocar Configurations
Part Number
Description
UOM
200-005-050
5mm x 70mm Bladeless Trocar
5
200-005-150
5mm x 100mm Bladeless Trocar
5
200-005-250
5mm x 150mm Bladeless Trocar
5
200-008-150
7/8mm x 100mm Bladeless Trocar
5
200-010-150
10mm x 100mm Bladeless Trocar
5
200-010-250
10mm x 150mm Bladeless Trocar
5
200-012-150
12mm x 100mm Bladeless Trocar
5
200-012-250
12mm x 150mm Bladeless Trocar
5
200-015-150
15mm x 100mm Bladeless Trocar
5
200-015-250
15mm x 150mm Bladeless Trocar
5
200-005-051
5mm x 70mm Bladeless Trocar and One Cannula (Threaded)
5
200-005-151
5mm x 100mm Bladeless Trocar and One Cannula (Threaded)
5
200-010-151
10mm x 100mm Bladeless Trocar and One Cannula (Threaded)
5
200-012-151
12mm x 100mm Bladeless Trocar and One Cannula (Threaded)
5
200-005-052
5mm x 70mm Bladeless Trocar and Two Cannulae (Threaded)
5
200-005-152
5mm x 100mm Bladeless Trocar and Two Cannulae (Threaded)
5
200-010-152
10mm x 100mm Bladeless Trocar and Two Cannulae (Threaded)
5
200-012-152
12mm x 100mm Bladeless Trocar and Two Cannulae (Threaded)
5
Bladeless Trocar Configurations (continued)
Part Number
Description
UOM
200-005-051
5mm x 70mm Bladeless Trocar and One Cannula (Smooth)
5
200-105-151
5mm x 100mm Bladeless Trocar and One Cannula (Smooth)
5
200-105-251
5mm x 150mm Bladeless Trocar and One Cannula (Smooth)
5
200-108-151
7/8mm x 100mm Bladeless Trocar and One Cannula (Smooth)
5
200-110-151
10mm x 100mm Bladeless Trocar and One Cannula (Smooth)
5
200-110-251
10mm x 150mm Bladeless Trocar and One Cannula (Smooth)
5
200-112-151
12mm x 100mm Bladeless Trocar and One Cannula (Smooth)
5
200-112-251
12mm x 150mm Bladeless Trocar and One Cannula (Smooth)
5
200-115-151
15mm x 100mm Bladeless Trocar and One Cannula (Smooth)
5
200-115-251
15mm x 150mm Bladeless Trocar and One Cannula (Smooth)
5
200-105-052
5mm x 70mm Bladeless Trocar and Two Cannulae (Smooth)
5
200-105-152
5mm x 100mm Bladeless Trocar and Two Cannulae (Smooth)
5
200-110-152
10mm x 100mm Bladeless Trocar and Two Cannulae (Smooth)
5
200-112-152
12mm x 100mm Bladeless Trocar and Two Cannulae (Smooth)
5
SHIELDED
TIP TROCAR
Shielded Tip Trocar
 Wedge Tip Design
 Minimizes defect size
 Maintains low insertion force
 Point is sharp – Sides are dull
 Spring Loaded Shield
 No locking mechanism in case of need to reenter the cavity
 Color Coded for Size Differentiation
 Orange – 5mm
 Green – 10mm
 Purple – 12mm
Shielded Trocar Configurations
Part Number
Description
UOM
100-005-090
5mm x 70mm Shielded Tip Trocar
10
100-005-190
5mm x 100mm Shielded Tip Trocar
10
100-010-090
10mm x 100mm Shielded Tip Trocar
10
100-012-090
12mm x 100mm Shielded Tip Trocar
10
100-005-091
5mm x 70mm Shielded Tip Trocar and One Cannula (Threaded)
5
100-005-191
5mm x 100mm Shielded Tip Trocar and One Cannula (Threaded)
5
100-010-191
10mm x 100mm Shielded Tip Trocar and One Cannula
(Threaded)
5
100-012-191
12mm x 100mm Shielded Tip Trocar and One Cannula
(Threaded)
5
100-005-092
5mm x 70mm Shielded Tip Trocar and Two Cannulae (Threaded)
5
100-005-192
5mm x 100mm Shielded Tip Trocar and Two Cannulae
(Threaded)
5
100-010-192
10mm x 100mm Shielded Trocar and Two Cannulae (Threaded)
5
PYRAMIDAL TIP TROCAR
 Very sharp pyramidal point
 Ease of insertion
 Less tissue trauma with straight stick – do
not twist
 Palm piece has comfortable feel
 Easy to handle
PYRAMIDAL TROCAR CONFIGURATIONS
Part Number
Description
UOM
100-005-000
5mm x 70mm Pyramidal Tip Trocar
10
100-005-100
5mm x 100mm Pyramidal Tip Trocar
10
100-005-001
5mm x 70mm Pyramidal Tip Trocar and One Cannula
(Threaded)
5
100-005-101
5mm x 100mm Pyramidal Tip Trocar and One Cannula
(Threaded)
5
100-005-002
5mm x 70mm Pyramidal Tip Trocar and Two Cannulae
(Threaded)
5
100-005-102
5mm x 100mm Pyramidal Tip Trocar and Two Cannulae
(Threaded)
5
100-105-001
5mm x 70mm Pyramidal Tip Trocar and One Cannula
(Smooth)
5
100-105-101
5mm x 100mm Pyramidal Tip Trocar and One Cannula
(Smooth)
5
100-105-002
5mm x 70mm Pyramidal Tip Trocar and Two Cannulae
(Smooth)
5
100-105-102
5mm x 100mm Pyramidal Tip Trocar and Two Cannulae
(Smooth)
5
Blunt Port (Hasson)
Blunt Port Suture Anchoring Device

Malleable silicone

Reduces defect size

Makes a better seal

Adjustable for precise depth
insertion
Available size 12mm

45º angle anchors for easy wrap


Suture grooves vs. wheels for
better fixation
Hasson/Blunt Port Configurations
Part
Number
Description
UOM
Hasson / Blunt Tip
400-012-130
10-12mm x 110mm Blunt tip Obturator w/ Suture Anchoring Device
5
400-012-131
12mm x 100mm Blunt tip Obturator and Cannula w/ Suture Anchoring
Device
5
Reducer Valve
5mm
5mm
baseball
cap
7/8mm
10mm
12mm
15mm
7/8mm to 15mm
Reducer Valve
(For instruments 5mm to 10mm)
Reducer Valves
All 5mm cannula have the same baseball cap valve (single
tab)
Easily removed – Easy grip tab
Plug reducer value (double tab) can be used with all 3mm5mm instruments in conjunction with universal valve
All 7/8mm – 15mm cannula have the same Universal
Valve
Fits instruments from 5mm – 15mm without losing
pneumoperitoneum
Air tight – dual seal technology
Bumps on inner/outer distal end of primary valve to
reduce drag
Can be easily removed from cannula for specimen
retrieval
Trocar In-Service
Techniques
VERESS NEEDLE
VERESS NEEDLE
•Spring mechanism
•Easy to use
•No valve adaptor
needed
•Available sizes
120mm
150mm
VERESS NEEDLE
ORDERING INFORMATION
Part
Number
Description
UOM
130-120-001
120 mm VERESS NEEDLE
20
130-150-001
150 mm VERESS NEEDLE
20
Laparoscopic
Instrumentation
Reusable Manual Instrumentation
Bi-polar
Mono-polar
Reusable Monopolar Instruments
Reusable Mono-Polar
• Modular system
– 3 Components
•Handle
•Insulated
Shaft
•Insert
INSERT
INSULATED SHAFT
• Sterilization
– Autoclave
– EtO
Advantages of Reusable Mono-Polar
• Easy assembly
• Easy cleaning
•Lumen brush
•Components apart
•Insert jaws open
•Handle open
• Inserts provide
excellent conductivity
Advantages of the GENICON Mono-Polar
•Variety of handles
•Rotates 360 degrees
•Comfortable and Light-weig
• One-Piece vs.
Modular System
• Two Components
• Three Components
Reusable Laparosco
Mono-Polar Instrumentation Hand
Axial Metal Handle with Ratchet
Rotating Insulated Handle with
HF Connector and switchable
ratchet
Rotating Insulated Handle with HF
Connector and ratchet
Rotating Insulated Handle
with HF Connector
Handle-to-Insert Harmonization
• Scissors Free-moving
• Graspers Ratching or Switchable Ratchet
• Dissectors Free-moving
• Needle Holders Axial
Mono-polar Options
• HANDLES:
– Free-Moving, Standard Ratchet, Switchable Ratchet,
Axial
• INSERTS:
– Graspers, Scissors, Dissectors, Specialty
Instrumentation (Biopsy Punch, Needle Holders)
• SHAFTS:
– Two standard lengths: 33cm or 45cm
– Available Sizes: 3mm, 5mm and 10mm
Bi-polar Laparoscopic
Instrumentation
• Modular system
– 4 Components
• Handle
• Inner Shaft
• Outer Shaft
• Working Insert
• Sterilization
– Autoclave
– EtO
Advantages of the GENICON Bi-Polar
•Ergonomic handle
•Rotates 45 degrees
•Coated non-stick inserts
• One-Piece vs. Modular
System
• Two Components
• Three Components
• Four Components
Bi-polar Options
• Multiple Tip Options
– Basic Four
•
•
•
•
Hirsch
Paddle Forceps
Micro Forceps
Kleppinger
• Available Lengths
- 33cm
- 45cm
• Adaptable to all
Generators
Disposable Monopolar
Features & Benefits
Full length insulation
protects tissue from
electrocautery arcs
Double action hinge
Full 360º
Rotation
Switchable
ratchet easily
operated with left
hand or right
hand
Angled HF
connector
Advantages
 Sterile (2 year shelf life)
 Reliable Quality with every new disposable instrument
 HF Connection for cauterization and dissection
 Full length insulation
 Double Action Jaws increases the range of jaw motion for
easier access and precision techniques
 Comfortable and Easy to Use
 360˚ Rotation
Single finger operation
LAVAGE SYSTEM
Features and Benefits of the Suction
Irrigation Handpiece
•High capacity tubing
•Easy flow
•Low clogging
•Ergonomic handpiece
•Easy to handle
•Added comfort
•Precision operation (double seal valves)
•Prevents leakage
Powered Suction
Irrigation
717-000-000 Irrigation Pump:
•GENICON Powered Irrigation Pump
•Tube Set
• 5mm x 33cm Powered Suction
Irrigation Tube Set with Handpiece
(710-305-033) – Worldwide Standard
Irrigation pump
Features and Benefits
•Easy Setup / Easy to Use
•Continuous High Flow Rate
•1.8 liters per minute
•Quiet
•Reusable
•Compact
•Can be mounted on an IV pole or placed on a table
Lavage System Accessories
Reusable vent probes and a line of mono-polar electrocautery probes
J Hook MonoPolar Probe
L Hook MonoPolar Probe
Spatula MonoPolar Probe
Reusable Vent
Probes
Technical Specifications of the 717-000-000
• Parastolic design
• Irrigation flow rate: 1.8 L/min
• Irrigation pressure: 400mm Hg (±
500mm Hg)
• High pressure safety feature: 500mm
Hg (after 5 sec) –shut down
• Weight: approx. 5.45 kg (12 lbs.)
Features: Suction/Irrigation Probes:
• Standard Probe
– Rolled Distal Tip
– Numerous vents at tip
• Mono-Polar Cauterization Probes
– Used to stop bleeding while irrigating in abdominal cavity
– Ceramic tip
• Helps to eliminate chance of arching inside the abdominal cavity
Mono-Polar Cauterization Probes:
Uses:
• Useful as blunt dissectors prior to activation
• Used to isolate tissue to be divided by the
current
– During Use: Tissue is hooked and tented up (away from
underlying tissue) to limit spread of current and to prevent
inadvertent damage
– May also be used to mark out a line for division
• Use heel of hook to create a dotted line using short bursts of soft
coagulating current
Specimen Retrieval Bag
Features
“UP” Indicator
26cm Introducer
235 or 350 cc
Capacity
Transparent Bag
10mm Diameter Tube
with Pre-loaded Bag
Specimen Retrieval Bag Ordering
Information
Part
Number
Description
UOM
Specimen Retrieval Bag
550-000003
10mm Specimen Retrieval Bag,
Medium (235 cc capacity)
10
550-000001
10mm Specimen Retrieval Bag
X-TRA Large (350 cc capacity)
10
Specimen Retrieval Bag - Features
•
•
•
•
•
•
•
•
•
•
Facilitates Specimen removal from the abdominal cavity
Minimize contamination of the abdominal cavity
Large bag - 235+ CC capacity
X-Large bag - 350+ CC capacity
Automatically opens bag upon deployment
120mm opening
For use with10mm or larger cannula
Easy to read indicator for bag orientation
Latex free
Packaged sterile (ETO), 10 per box
2009 New Products
• Titanium Clips
• Clip Applicator
• Disposable Articulated
Disector
6869 Stapoint Court, #114
Winter Park, FL 32792
Primary Phone +1.407.657.4851
USA Toll-Free
800.936.1020