Transcript Range name:

Range name:
Range code:
alifter
TMA
•T Magnetic
•M Close-coupled
•A Self-priming (Alifter range)
Name of the model:
•01 nominal Capacity (m3/h)
•16 related head ( m )
01.16
hydraulic connections correlated to the rotation
cwr: outlet
ccwr: inlet
cwr : inlet
ccwr: outlet
ccwr
cwr
filling hole
components
1 O-ring and cap at the filling-hole of the part B
Central casing
B
Rear casing
C
Connection casing
A
1 O-ring between parts B and C
Same component as front and rear bushing
Impeller assembly: impeller separable from inner-magnets
2 O-rings between parts A and B
1 O-ring for each connection-side
TMA
main features
•Start-up with empty pipes
•Fast priming-phase
•Maximum Lift = -5 m
•Reversible (inlet-outlet reversal)
•Suitable for spacific weight up to 2 kg/m3
•Suitable for vapour pressure up to 1 m (H2O @ 45°C)
•Minimum NPSHa (available on the plant) = 3 m (abs)
•Impeller replaceable apart from magnets
25
priming-time
(sec.)
20
15
10
5
Priming-time with water
0
-1
-1.5
-2
-2.5
-3
-3.5
Lift (m)
-4
-4.5
-5
-6
Model 01.16
25.0
20.0
head (m)
performance
curve
15.0
10.0
5.0
0.0
0
0.5
1
1.5
2
2.5
3
2
2.5
3
Differently centrifugal pumps,
Alifter pumps increase power
reducing capacity
Sound pressure (approx. 82 dB)
is higher in comparison with
centrifugal pumps: it is a direct
result of the operational principle
input power (kW)
capacity (m3/h)
0.65
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0
0.5
1
1.5
capacity (m3/h)
motors
3 motors available for each model
for pumping different specific weights:
0.55 kW
0.75 kW
1.1 kW
N
P
S
1.1 kg/dm3
1.5 kg/dm3
2 kg/dm3
IEC motors in constructive form:
B34
NEMA motors in constructive form: C flanged
materials
Casings
Impeller
GFR-PP
O-ring
Bushing
Shaft
Thrust ring
CFF-ECTFE
FKM / EPDM
CarbonGraphite
GFRPTFE
Al2O3
SiC
CarbonGraphite
GFRPTFE
SiC
SiC
dimension notes
DN = 20 mm
Arrows on the connectioncasing show the outlet related
to the rotation
The pump is fixed to the ground
with the holes of the motor-feet
The two hydraulic connections have same dimensions
details identification in Intraset
spare parts
negative Suction Head - Hs
Relation among: Lift – Temperature – Specific weight
valid for “priming phase”
Temperature:
T (Celsius deg)
Vapour Pressure of Water
ref. to T
Pv (m)
20
40
50
60
65
70
75
80
0.24
0.75
1.25
2.05
2.65
3.3
4.1
5
2.0
2.0
-1.6
-1.3
-1.1
-0.9
-0.8
-0.7
-0.6
2.0
-1.6
-1.2
-0.9
-0.8
-0.7
-0.6
-0.5
-0.5
Pressure at level of fluid
HB (m)
10.33
Lift
HS ( m )
-1
-1.5
-2
- 2.5
-3
- 3.5
-4
- 4.5
-5
In general terms:
max. value of specific weight of the fluid
2.0
2.0
2.0
2.0
2.0
-2.0
-1.8
-1.6
-1.4
2.0
2.0
2.0
2.0
2.0
-1.9
-1.6
-1.5
-1.3
2.0
2.0
2.0
2.0
-2.0
-1.7
-1.5
-1.4
-1.2
2.0
2.0
2.0
2.0
-1.8
-1.5
-1.3
-1.2
-1.1
2.0
2.0
2.0
-1.9
-1.6
-1.3
-1.2
-1.0
-0.9
H B  Pv  H S    3
2.0
2.0
-2.0
-1.6
-1.3
-1.2
-1.0
-0.9
-0.8
applications
Water taking for testing