Automatic Sprinkler Systems
Chapter 13
Ricky Phillips, Instructor
1
Automatic Sprinkler Systems
Most reliable fixed extinguishing system
No reported multiple deaths in a
completely sprinkled building
Controls 70% of all fires with five or
fewer sprinklers activated
Ricky Phillips, Instructor
2
Automatic Sprinkler System
Consist of sprinkler heads
– arranged to automatically distribute water
directly to the fire
Water supplied through a system of
piping
Ricky Phillips, Instructor
3
Two types of Sprinkler Coverage
Complete Sprinkler Coverage
– protects the entire building
Partial Sprinkler Coverage
– protects only certain areas
• high hazards, exit routes, places required by
code or AHJ
Ricky Phillips, Instructor
4
NFPA 13
Standard for the Installation of Sprinkler
Systems
Requirements on spacing, pipe size,
and all details concerning the
installation of sprinkler systems
Ricky Phillips, Instructor
5
NFPA 13D
Standard for the Installation of Sprinkler
Systems in One and Two Family
Dwellings and Mobile Homes
Ricky Phillips, Instructor
6
FM or UL Listings
All parts of system regulated by
– Factory Mutual
– Underwriters Laboratories
Ricky Phillips, Instructor
7
Effects on Life Safety
Life Safety is enhanced
– fire is extinguished will small
Combustion products are limited
– extinguishment in incipient stage
Presence is crucial in high-rise buildings
Ricky Phillips, Instructor
8
System Fundamentals
Sprinklers
Sprinkler Design
Sprinkler Storage
Control Valves
Water Flow Alarms
Water Supply
Fire Department Connection
Ricky Phillips, Instructor
9
Ricky Phillips, Instructor
10
Sprinklers
Discharge water
Fusible Link
Glass Bulb
Chemical Pellet
Quick Response
Ricky Phillips, Instructor
11
Sprinkler Design
Pendant
Upright
Sidewall
Special Sprinklers
Ricky Phillips, Instructor
12
Sprinkler Storage
Storage Cabinet
– extra heads
– sprinkler wrench
Changing sprinkler heads should only
be performed by representatives of the
building’s occupants.
Ricky Phillips, Instructor
13
Control Valves
OS&Y Valve
Post Indicator Valve (PIV)
Post Indicator Valve Assembly (PIVA)
Operating Valves
Ricky Phillips, Instructor
14
Waterflow Alarms
Hydraulic or electrical
warn of water movement in system
Hydraulic alarm sounds local
Electrical alarm sounds local and fire
alarm system
Ricky Phillips, Instructor
15
Water Supply
Ricky Phillips, Instructor
16
Fire Department Connection
Provides outside source of water supply
Consists of at least two 2-1/2” female
connections or one LDH connection
Supplied by pumper with minimum
1,000 gpm pump or greater
Minimum of two 2-1/2” lines
PDP of 150 psi.
Ricky Phillips, Instructor
17
Types of Systems
Wet-Pipe
Dry-Pipe
Pre-Action
Deluge
Residential
Ricky Phillips, Instructor
18
Wet-Pipe System
Ricky Phillips, Instructor
19
Dry-Pipe System
Ricky Phillips, Instructor
20
Deluge System
Ricky Phillips, Instructor
21
Pre-Action System
Ricky Phillips, Instructor
22
Residential System
Ricky Phillips, Instructor
23
Factors & Considerations
Ricky Phillips, Instructor
24
Controlling Water Flow from a
Sprinkler Head
Ricky Phillips, Instructor
25