Anionic Surfactant Detection

Download Report

Transcript Anionic Surfactant Detection

In Aqueous Environments

John Raia Chem 4101 December 9 th , 2011

The Problem

 In the Deep Water Horizon catastrophe that occurred Spring of 2010, over 1 million gallons of an undisclosed mixture of sulfonated anionic surfactants (Corexit®) were sprayed across the oil spill site to act as an oil dispersant agent.

 Some specific anionic surfactants have known toxicities for various marine species (especially green algae, sea turtles, and dolphins). They are also known to have severe respiratory and digestive issues in humans are suspected causers of human endocrine disruption.

 Over time the migration of the surfactants could effect ecological systems many miles away from where they were originally introduced.

§ § Kerr, R. A. A Lot of Oil on the Loose, Not So Much to Be Found.

Science 2010, 329 , 734-735.

Hypothesis

 It is crucial to be able to identify specific anionic surfactants that are still present in aqueous environments.

 Since migration of surfactants throughout aqueous sources is an issue, quick and effective methods of sampling, detection

and characterizing surfactants is essential.

By monitoring the deaths of migrating aquatic species (i.e. dolphins and sea turtles) found around coastal shores, a direct correlation to the presence of anionic surfactants in water in that area hopefully can be made, and the contents can be analyzed both quantitatively and qualitatively.

º

ºNelson, Karen. One year later, Gulf oil disaster claims, questions unsettled http://www.duluthnewstribune.com/event/article/id/196672/ (accessed October 16th, 2011)

Classification of Anionic Surfactant Species

Dioctyl Sodium Sulfosuccinate (DOSS) * • • • • 444.216 Da CAS #: 577-11-7 Molecular Formula: C 20 H 37 NaO 7 S MP: 153–157 °C • • • • •

Classifications

1

Soaps : C n H 2n+1 COO X

Alkyl Sulfates (AS) Linear Alkylbenzene Sulfonates (LAS)

and Secondary Alkyl Sulfonates (SAS) : C n H n+1 SO 3 X

Alkylether Sulfates (AES): C n H 2+l (OCH 2 CH 2 ) n -OSO 3 X

Fluorinated: C n H 2n-1 OPO(OH)O X

Approx. 1 million gallons of sulfonated surfactant mixture dispersed in 6.43 E 17 gallons of marine water. (detection limit

from 1ppt to 3ppm) º * Sigma-Aldrich.

(accessed Oct 26, 2011).

Other standards for comparison can be purchased accordingly

Sampling and Extraction

Sampling

 Costal regions  Beached migrating aquatic species with known toxicities   Sampled radially, with constant distance Positive sampling for anionic surfactants should be resampled at varying depths •

Solid Phase Extraction (C18 cartridge)

2

100 mL sample of seawater Condition w/ MeOH and H 2 O Frozen with 4% formaldehyde until analysis

Possible Separation Methods

Method

Capillary electrophoresis 2 Gas Chromatography 3 HPLC (Reverse Phase) 1,5,6,7 • • • • • • • • •

Advantages

Reduced demand for organic solvents Short time for analysis Easy to carry out Can be paired with tandem MS Lower concentrations of single analyte can be measured Lower limit of detection compared to HPLC All groups of anionic surfactants can be analyzed Low volatile analyte can be determined Various methods of detection are available for coupling • • • • • • •

Disadvantages

Large sample volumes would be hard to quantitatively analyze LOD without painstaking sample prep Limit capability for compounds with low volatility Derivitization of analyte is necessary Apparatus is complicated and can be more expensive than HPLC Costly analysis (very pure solvents) Expensive equipment Produces toxic wastes

Possible Detection Methods

Method

UV-Vis † Mass Spec 1 • • • • •

Advantages

Quick Inexpensive provides specific information about MW and structure Specific tailoring for analyte in question Many options (Ion Trap, Triple Quad, TOF… etc.) • • • • •

Disadvantages

Limited usage with specific conjugated surfactants (e.g. LAS) AS and AES must be coupled with conjugating dyes to emit detectable wavelength Expensive Many parameters for consideration Destruction of sample † Yuxiu A. et al. Soft Matter. 2011, 7, 6873.

Method of Choice: HPLC-MS

    Reversed Phase Column (C18)  Gradient elution for lowering time of detection Ion Trap Mass Spec Atmospheric Ionization Source with ESI   Full scan mode Fragmentations from 75 to 800 m/z LOD – 0.00021 ug/L (1ppt = 1 ug/L) 1 http://www.forumsci.co.il/HPLC/system.gif

Equipment

Column: LiChristopher 100 RP-18 (Merck)

(9)  250mm x 2mm and 3um particle diameter 

HPLC- Ion Trap MS

(5)  Atmospheric pressure Chemical Ionization  Negative Ion Quadrupole Mode

LCQ Fleet Ion Trap Mass Spectrometer from ThermoScientific

Example Data

(4)

Conclusion

The methods that were proposed allow not only for the detection and presence anionic surfactants at low limits of detection that are needed for the study of anionic surfactants in the gulf, but also allow for differentiation of homologues as long as a standard comparison is present.

References

         ( 1 ) Olkowska, E.; Polkowska, Ż.; Namieśnik, J. Analytics of surfactants in the environment: problems and challenges.

Chem. Rev. 2011, 111 , 5667-5700. ( (2 ) Riu, J.; Eichhorn, P.; Guerrero, J. A.; Knepper, T. P.; Barceló, D. Determination of linear alkylbenzenesulfonates in wastewater treatment plants and coastal waters by automated solid-phase extraction followed by capillary electrophoresis–UV detection and confirmation by capillary electrophoresis–mass spectrometry.

Journal of Chromatography A 2000, 889 , 221-229.

( 3 ) Alzaga, R.; Peña, A.; Ortiz, L.; Marı ́a Bayona, J. Determination of linear alkylbenzensulfonates in aqueous matrices by ion-pair solid-phase microextraction–in-port derivatization–gas chromatography–mass spectrometry.

Journal of Chromatography A 2003, 999 , 51-60.

(4 ) Lara-Martín, P. A.; Gómez-Parra, A.; González-Mazo, E. Simultaneous extraction and determination of anionic surfactants in waters and sediments.

Journal of Chromatography A 2006, 1114 , 205-210.

( 5 ) Petrovic, M. Determination of anionic and nonionic surfactants, their degradation products, and endocrine-disrupting compounds in sewage sludge by liquid chromatography/mass spectrometry.

Anal.

Chem. 2000, 72 , 4560.

(6 ) Poppe, A. Negative-ion mass spectrometry. X. A spurious [CH5]- ion: problems with negative chemical ionization quadrupole instrument.

Org. Mass Spectrom. 1986, 21 , 59.

( 7 ) Boiani, J. Spectator ion indirect photometric detection of aliphatic anionic surfactants separated by reverse-phase high-performance liquid chromatography.

Anal. Chem. 1987, 59 , 2583.

( 8 ) An, Y.; An, Y. Disassembly-driven colorimetric and fluorescent sensor for anionic surfactants in water based on a conjugated polyelectrolyte/dye complex.

Soft matter 2011, 7 , 6873.

(9) LiChrospher® 100 RP-18 and RP-18 Endcapped | Merck Chemicals International

http://www.merck chemicals.com/lichrospher-100-rp-18-and-rp-18-endcapped/c_DMOb.s1LSAoAAAEWsOAfVhTl

(accessed 11/11/2011, 2011).