Transcript Slide 1

WIRING DIAGRAM – 1 DOOR CF CAR PARK CONTROLLER
RJ45 CONNECTOR COLOUR CODE
DIRECT CABLE CROSS CABLE
White Green
Green
White Orange
Blue
White Blue
Orange
White Brow n
Brow n
IN READER
+12V----- RED
0V ------BLACK
D1-----WHITE
D0-----GREEN
GLED----ORANGE (AY-H020)
GLED-----BROWN (RD-J12)
GLED-----GREY (AY-Y20B)
BUZZ-----PURPLE(AY-Y20B)
BUZZ-----YELLOW(AY-H020)
OUT READER
GLED
GLED
BUZ
D0
D1
0V
12V
White Orange
Orange
White Green
Blue
White Blue
Green
White Brow n
Brow n
D0
D1
0V
12V
1
2
3
4
5
6
7
8
ENTRY
LOOP DETECTOR
Note:
1) In Loop Detector (PB) must be
connected to 0V if In Entry Loop
Detector is not use
NO
3) JP5 and JP6 are to set the
respective relay to normally open and
closed All relay are set to normally
open for Car Park Barrier and are of
dry contact
JP2
JP1
NORMAL /
RESET
JP8
14VAC
JP5
JP4
RY 1
RY 1
JP7
RY 2
RY 2
JP6
ENTRY
BARRIER
C2
02
C1
01
0V
+12
JP9
Then the IP for the door
controller would be
192.168.0.XX
JP10
XXXXX
NO/NC
EXIT
BARRIER
PWR
NO/NC
AC
+
Important: Please do not connect reader unshielded
cable and reader any cable to earth.
PUSH BUTTON
EXIT
PUSH BUTTON
JP3
RJ-45
COM ENTRY
COM
DOOR 1
IP ADDRRESS
The default IP address should
be showed on a warranty
sticker with a square onto the
numbers. Example:
NO
0V
IN2
IN1
L2
PB
DS
TP
BZ
L1
D0
D1
D0
D1
0V
12V
2) Out Loop Detector (DS) must be
connected to 0V if Out Entry Loop
Detector is not use
EXIT
LOOP DETECTOR
RELAY SETTING
closed- power / open- dry contact
JP4 is for relay 2 (RY2)
JP4 is for relay 1 (RY1) SHORT
230VAC
-
Battery
By AZWAN 17-11-2011