Portable Instrument Distributor Training 2001
Download
Report
Transcript Portable Instrument Distributor Training 2001
ALTAIR® 4X Multigas Detector
It’s what’s inside that counts!
Our Vision of Safety
Built on Durability
– Based on tough Altair 4 Multigas Detector
Powered by Performance
– New High Performance XCell™ Sensors
XCell Technology
Typical life >= 4 Years
– 60% longer sensor life than the industry average
– Standard 3 year warranty
XCell-erated response time, clear time, bump test
– 38% faster response time than the industry average
– Typical <= 15 seconds
Typical cost of ownership savings > 50%
– Longer sensor life and fast response
– 50% less calibration gas used per minute than industry average
Embedded microelectronics elevate performance
– Each sensor has a microprocessor and digital output
Application Specific Integrated Circuit
(ASIC)
Industry 1st! Every XCell Sensor has an embedded ASIC!
– Microprocessor, memory, and all circuitry to drive the sensor
– Digital output
Way beyond a “Smart Sensor”
– Competitor’s “Smart Sensors” have a passive memory chip to store
gas type, serial number, initial sensor settings, etc….
– The MSA ASIC drives the sensor, actively compensates the output,
and coverts it into a digital signal.
Benefit
– Higher performing sensors with greater stability
XCell O2 Sensor Life
Most Other O2 Sensors (Typical Life <= 2 years)
– Use a consumable chemical reaction
– Filled with lead which is converted to lead oxide
– Sensor dies as lead is depleted (limited shelf life)
XCell O2 Sensor (Typical Life >= 4 years)
– Non-consuming chemical reaction (No lead)
– O2 reduced to water and then oxidized back to O2
– Vastly increased shelf life
XCell Ex Sensor Life
Most Other LEL Sensors (Typical Life = 2 years)
– End of life caused by slow poisoning
• Poisoned by silicon, sulphur, or lead containing compounds
– End of life can also result from a large physical shock
XCell Ex Sensor (Typical Life = 4 years)
– Two detectors double the active life of the sensor
– Only one detector is catalytically active at a time
– Metal alloy support rod added to increase durability
XCell CO/H2S Sensor Life
Most Other CO/H2S Sensors (Life = 2-3 years)
– Chemical poisoning of the electrode material
– Loss of sensitivity due to electrolyte drying out
XCell CO/H2S Sensor (Typical Life >= 4 years)
– Increased active sites on electrodes
• Increase sensitivity
• Reduce the effects of poisoning
– Robust carbon filter to protect the CO electrode
– Expansion electrolyte well minimizes drying effect
Response Times
Significantly Faster Than the Competition!
Span Calibration: 60 sec
Bump Test: < 15 sec
Combustible sensor t90 <10 seconds (Methane)
t90 <15 seconds (Pentane)
Oxygen sensor
t90 < 10 seconds
CO sensor
t90 < 15 seconds
H2S sensor
t90 < 15 seconds
XCell Sensor
Designed and built by MSA
– MSA IS Advancing Sensor Technology!
– Our sensors are designed for OUR instruments!
– We have the experts to support YOU!
Altair 4X Multigas Detector
Personal 4-gas monitor
– Detects O2, H2S, CO, combustible gas
– Rechargeable lithium-polymer battery
Standard:
– Event log
– Full data log
– Vibrating alarm
– MotionAlert™
– InstantAlert™
Small Size
Small, unobtrusive,
lightweight design
Easy to wear all day
Alarms visible from 360º
Fits in gloved hand
One-handed operation
Robust construction
Rugged Design
Over-molded case design
Built-in rubberized armor
Impact shock protection
– Withstands 20-foot drop
Easy to grasp and hold
Sealed against water/dust
ingress to IP67
– Third-party tested
– Dunk it in a bucket!
Multiple Alarms
95+ dB horn typical
Multiple, alternating high-intensity alarm LEDs
– On top and bottom of unit!
Vibrating alarm is standard on all models
InstantAlert™ feature standard
– Activates all alarms when desired
MotionAlert™ feature standard
– If no motion is detected for 30 seconds,
alarm sounds to alert others
– Ideal for confined space entry
Provides Confidence
Confidence signal
– Green blinking Safe LED
– Vibrating pulse
– Confidence beep every
30 sec. to ensure operation
Can be turned off
– Setup mode
Advanced Features
MSA exclusive MotionAlert™ feature
– Indicates “man down”
MSA exclusive InstantAlert™ feature
– Activates all alarms when desired
Most rugged instrument in its class
– Withstands 20-foot drop
Agency certified IP67 rating
– Water and dust tight
Bump checkmark √ (24 hrs)
– Displays successful test result
Advanced Features
Safe LED
– Helps to ensures instrument’s
proper operation
Missing sensor alarm
– Helps to prevent errors after service
Password-protected setup mode
– Controls unauthorized access
Event & data log
– >500 events and >50 hours
MSA Link™ Software-ready
– Multi-language PC software
to access records & change settings
Battery
Lithium-polymer technology
Virtually no memory effects
Holds charge better
Runs average of 24 hours
– No need for multiple instruments during long shifts
Many Markets
Oil and gas
Chemical
Fire
Utilities
Agriculture
Construction
Steel
Water
Various industrial applications
Start-up
Operation similar
to that of Altair 4 & Solaris® Multigas Detectors:
Performs diagnostic self-check
– Display
– 3 alarms
– Sensor discovery
Displays:
–
–
–
–
–
Instrument name
Software version
Combustible gas type
Toxic units (ppm or mg/m3)
Alarm set points (Low, High, STEL, TWA)
Start Up
Displays expected
calibration gas concentrations
Shows current time and date
Indicates last successful cal. date
Indicates next cal. date (if activated)
Shows measurement countdown
Offers fresh air setup option
Defaults to measurement page
Pages
Measurement (default)
Bump
Peak readings
Minimum oxygen reading
STEL for toxics (if activated)
TWA for toxics (if activated)
Time
Date
MotionAlert™ feature
Data Log
Event logging (500 events)
–
–
–
–
–
Gas and battery alarms
Calibration & bump records
Battery voltage
FAS, re-zero, calibration
Reset of TWA, STEL & Peak
Gas records(>50 hours)
–
–
–
–
Reading
Time and date
Peak, Min, Average
Temperature
Graphs & tables
Infrared-based MSA Link Software-compatible
– Change instrument settings
Last successful calibration date
Setup
Password-protected access
Change:
–
–
–
–
–
–
–
–
Individual sensor channels
Combustible gas type
Auto calibration values
Calibration due on/off
Alarm set points
Low, High, STEL, TWA
Date
Time
Other settings through MSA Link Software
Calibration
Single-button auto cal-based
– Access can be password-protected
®
Same Altair 4 & Solaris Detector
calibration cylinders
–
–
–
–
1.45% CH4
60 ppm CO
15% O2
20 ppm H2S
• 10048280 (34L)
• 10045035 (58L)
Calibration
1. Press and hold ▲ button
2. Instrument prompts user to “Zero Cal?”
3. Press
to accept & initiate zero function
– Or press ▲ to cancel function
4. Unit will automatically zero sensors
– Zero pass
5. Instrument prompts user to “Span Cal?”
6. Attach cal. cap & flow cal. gas to instrument
7. Press to accept & initiate span
– Or press ▲ to cancel function
8. Unit automatically spans sensors
Accessories
Galaxy® Automated Test System
– Bump test and calibration
– Record keeping
QuickCheck® Station
– Bump test only
– Records activities
Charging cradle
Multi-Unit Charger
– Up to 10 instruments
Universal pump probe
Low Maintenance
Low level of end-user maintenance required:
Separate sensors
Sensor replacement kit
Filter, gasket, etc. kit
Front case with built-in filter
Battery and electronics
Most components available as replacement parts
Warranty
Standard 3-year warranty
– Sensors
– Electronics
– Battery
Optional extended warranty
– 1 year extra = 4 years total
– Part of ATO!
Questions?
Thanks!