Winchester Fire Rescue

Hoselines

Definition-

Fire hose

of flexible tube used by firefighters to carry water under pressure from the source of supply to a point where it is discharged.

is identified as a type

Hose Construction-Depending on its intended use, fire hose is manufactured in different configurations such as single-jacket, double-jacket, rubber single-jacket, hard rubber non-collapsing types.

Sizes- Each size of hose is designed for a specific purpose. Sizes range from 1 ½ - 6 inches and is most commonly cut and coupled into lengths of 50 and 100 feet for convenience of handling and replacement, but other sizes may be obtained.

Note: Reference made to diameter of fire hose refers to the dimensions of the inside diameter of the hose.

Woven Jacket Hose 1- to 6-Inch (25 mm to 150 mm) VS 12A-1

HOSE CONSTRUCTION

Type Booster Hose ¾- or 1-Inch (19 mm to 25 mm) Description

• • •

Rubber Covered Rubber Lined Fabric Reinforced

One or Two Woven

Fabric Jackets Rubber Lined Impregnated Single Jacket Hose 1½ to 5-Inch (38 mm to 125 mm) Noncollapsible Intake Hose 2½- to 6-Inch (65 mm to 150 mm) Flexible Noncollapsible Intake Hose 2½- to 6-Inch (65 mm to 150 mm)

• •

Polymer Covered Polymer Lined

• •

Rubber Covered Fabric and Wire (Helix)

Reinforced Rubber Lined

• •

Rubber Covered Fabric and Plastic (Helix)

Reinforced Rubber Lined

  

Fire hose couplings

Couplings are used to connect fire hose with appliances, other fire hose and fire department apparatus. There are several different types of fire hose couplings used in the fire service.

The most commonly used fire hose couplings are the

threaded

and

storz

type.

VS 12A-2

TYPES OF HOSE COUPLINGS

Threaded Threaded Five-Piece Three-Piece Snap Reducing Coupling Quarter-Turn Coupling Storz Quick Connect (Sexless Coupling)

Threaded

  Each threaded coupling is manufactured with lugs to aid in tightening and loosening connections. There are three types of lugs: pin, rocker and recessed.

 

Pin lugs

are not commonly ordered with new hose because of their tendency to snag when hose is dragged over objects.

Recessed lugs are commonly found on hose, are shallow holes drilled into the coupling, and are designed to accept a special spanner wrench.

Booster

Note: Spanner wrenches are wrenches used to tighten and un-tighten fire hose couplings.

   Most hose purchased today comes equipped with

rocker lugs

to help the coupling slide over obstructions when the hose is moved on the ground or around objects.

An added feature that may be obtained with the threaded couplings is the

Higbee cut and indicator. The Higbee cut is a special type of thread design in which the beginning of the thread is “cut” to provide a positive connection between the first threads of the opposing couplings, which tends to eliminate cross threading.

TYPES OF COUPLING LUGS

Recessed Lug Extended Handle VS 12A-3 Rocker Lugs Pin Lug

  One of the rocker lugs on the swivel (female end) is scalloped with a shallow indention, the Higbee indicator, to mark where the Higbee cuts begins. This indicator aids in the matching of the male coupling thread to the female coupling thread, which is not readily visible.

 

Storz couplings

Storz couplings

are sometimes referred to as sexless couplings because there are no distinct male or female components. When mated, the lugs of each coupling fit into the recesses in the opposing ring and then slide into locking position with a

1/3 turn.

   Intake Supply Attack

Types of Fire Hose

TS 12A –2

 Attack hose — 400 ft. (122 m) of 1½-, 1¾-, or 2-in. (38 mm, 45 mm, or 50 mm)  Supply hose — 1,200 ft. (366 m) of 2½ in. (65 mm) or larger  Soft-sleeve intake hose — 15 ft. (5 m), large diameter, or hard-suction intake hose — 20 ft. (6 m)

NFPA 1901 PUMPER HOSE REQUIREMENTS

 

Intake

There are two groups within this category:

soft sleeve and hard suction.

Soft sleeve is used to transfer water from a pressurized water source, such as a fire hydrant, to the pump intake and is available in sizes ranging from 2 ½ to 6 inches.

Hard suction hose (also called hard sleeve) is used primarily to draft water from an open water source and is also available in sizes ranging from 2 ½ to 6 inches.

  

Supply Line

Supply line is identified as the hose between the water source and the attack pumper to provide large volumes of water.

Supply line sizes range from 2 ½ to 5 inch hose.

Other sizes are available, but these are the most commonly found sizes.

   

Supply Line Lays

There are three basic hose lays for supply hose: forward lay, reverse lay and split lay.

With the

forward lay

, hose is laid from the water source to the fire.

With the

reverse lay

, hose is laid from the fire to the water source.

The term hoses.

split lay

can refer to any one of a number of ways to lay multiple supply

FORWARD HOSE LAY

VS 12B-1

REVERSE HOSE LAY

VS 12B-2

SPLIT HOSE LAY

VS 12B-4

   Friendship- Both the Wagon and Rescue Engine carry 1200 feet of 4” and 500 feet of 3”. Shawnee- Both the Wagon and Engine carry 1000 feet of 4” and 500 feet of 3”.

South End- Both the Wagon and Engine carry 1000 feet of 4” and 300 feet of 3”.

 

Special considerations referring to supply line in Winchester City Fire-Rescue.

A nominal expectation of a gutterlined 4” supply line is

400 GPM

more than and

500 feet 400 GPM

. Which means if you’re going to supply yourself without another pumper between you and the hydrant, you should not flow and be any farther than

500 feet

from the hydrant, per SOG-06-06.

Supply Operations: A minimum of of which type of lay, a minimum of 06-06.

25

feet of hose is to accompany the coupling when the line is pulled. Which means whenever supply line is laid regardless

25

feet is to accompany the coupling/hydrant adapter, per SOG-

  

Preconnected Hose Loads/Attack Line

Attack line

is defined as hose between the attack pumper and the nozzle used to control and extinguish fire.

Medium attack line sizes range from

hose. to

2

inch There are several different ways of packing/loading pre-connected attack lines on fire apparatus.

Crosslays

Friendship

uses a version of the Minuteman Hose Load on both the Rescue Engine and the Wagon

Crosslays

Shawnee

uses the same version of the Minuteman Hose Load on the Engine which utilizes “speed trays” and uses the Pre-connected Flat Load on the Wagon .

Crosslays

South End uses a different version of the Minuteman Hose Load on both the Engine and the Wagon.

Note: All city engine company’s medium sized attack line “crosslays” are

1-¾”

hose and

200

feet long. Note: “Speed Trays” are trays placed on the ground that a preconnected hose line is packed/loaded in so hose can be loaded and unloaded quickly on/off fire apparatus.

Note: Each of the above mentioned hose loads will be demonstrated and you will have the opportunity to practice loading and pulling each after the lecture.

  

Pre-connected attack lines other than crosslays in the City of Winchester

Friendship- Both the Wagon and the Rescue Engine have a 300 ft. “Apartment line” made up of 150 feet of 1-¾”, and 150 feet of 2-½” hose. A 200 ft. “Blitz line” which is made up of 2-½” hose. The Rescue Engine has a 300ft. 1-¾” attack line loaded on the rear. The Wagon has a 200ft. ¾” booster reel mounted on the top and a 100 ft. 1-¾” “Bumper line” on the bumper.

  

Shawnee-

of 3” hose. Both the Wagon and the Engine have a 300 ft. “Apartment line” made up of 150 feet of 1-¾”, and 150 feet Both also have a 100ft. 1-¾” “Bumper line” on the bumper.

The Engine has a 200ft. ¾” booster reel mounted on top and a 200ft. 2-½” line attached to the “Blitz Fire”.

    South End- Both the Wagon and the Engine have a 400 ft. “Apartment line” made up of 200 feet of 1-¾”, and 200 feet of 2½” hose.

Both also have a 100ft. 1-¾” “Bumper line” on the bumper and a 150ft. ¾ ” booster reel mounted on top.

The Engine has a 200ft. 2-½” line attached to the “Blitz Fire”. The Wagon has 200ft. 1-¾” pre-connect loaded on the rear.

VS 12B-18

ADVANCING AN UNCHARGED LINE UP AN EXTERIOR STAIRWAY

Pike Pole Method

Connection One

ADVANCING A LINE FROM AN UPPER-FLOOR STANDPIPE

VS 12B-19

HOISTING HOSE

Uncharged Line Charged Line VS 12B-22

OPERATING AN ATTACK LINE FROM A LADDER

VS 12B-24

VS 12B-28

HANDLING A LARGE-SIZED CHARGED HOSELINE (ONE FIREFIGHTER)

Nozzle Under Loop Sitting on Hose at Point Where it Crosses

VS 12B-29

HANDLING A LARGE-SIZED CHARGED HOSELINE (TWO FIREFIGHTERS)

Feet Braced Against Each Other

Firefighters on Same

Side of Hose Using Rope Hose Tool or Strap to Support Hose

Nozzle at Waist Level

Feet Spread Apart for Balance

Hand on Nozzle Bale

     

Service Testing Fire Hose

Fire Hose is required to be tested

annually .

Fire Hose should also be tested after being

repaired

and after being

run over by a vehicle .

All new hose has the service test pressure stamped on the hose. Per AP-06-11, hose should be laid in lengths of no more than

300

ft. Connect lines to be tested to gated outlets of the pumper. Attach shut-off nozzles to the far end of lines. Secure both ends of the hose line.

     Support the hose line being tested with a belt tie and or a rope hose tool at a point 10 or 15 inches from the butt coupled to the pumper discharge.

Connect lines to be tested to gated outlets of the pumper. Attach shut-off nozzles to the far end of lines. Secure both ends of the hose line.

Support the hose line being tested with a belt tie and or a rope hose tool at a point 10 or 15 inches from the butt coupled to the pumper discharge.

      With the gate valves open and the nozzle open, fill the hose with the water at a pressure not exceeding 100 PSI to allow air to be exhausted from the hose. Once all the air is exhausted close gates.

The hose is to be pressurized at

250

psi for

5

minutes for all rubber jacketed hose. 4” hose is to be tested at

200

psi for

5

Personnel should keep a distance of unless inspecting the hose/coupling.

15

minutes.

feet Hose that leaks may need a rubber gasket.

VS 12A-4

REPLACING A HOSE COUPLING GASKET

1. Remove old or damaged gasket.

2.

Hold new gasket between middle finger and thumb, with index finger on inside rim.

3.

Fold outer rim upward with index finger; then slip gasket into swivel, large loop first.

  If hose continues to leak it should taken out of service and repaired.

If a coupling has moved during the test, tag the hose section for re-coupling.

 Tag all hose that has leaked or failed in any other way.

Note: Expect a

1/16”

to testing, note for record

1/8”

uniform movement of the coupling on newly coupled hose. This slippage is normal during initial testing but should not occur during subsequent tests. If movement is indicated during subsequent

  

General care and Maintenance of Fire Hose

If fire hose is properly cared for, it’s life span can be extended appreciably.

Dirt and dust can be brushed away, any dirt that can not be removed from brushing should be washed and scrubbed with water.

Hose that has been exposed to oil, should be washed with

mild soap

or detergent, making sure that all the oil is completely removed and then rinsed thoroughly with water.

TYPES OF HOSE DAMAGE

Mechanical Damage Thermal Damage VS 12B-32 Mildew and Mold Damage Chemical Damage

WASHING HOSE COUPLINGS

Mechanical Manual (Woven Jacket) VS 12B-33 Female Coupling Male Coupling

   Hose should be

dried

placed in storage.

before repacking or Hose should be dried in accordance with local procedures and manufacturer’s recommendations.

Locally, hose is washed and hung in a hose tower until dry.

DRYING HOSE

Rack Tower Mechanical VS 12B-34

Manual References Winchester Fire–Rescue Department

 Apparatus & Equipment, AP-06-11(Hose Testing)  Operations, Standard Operating Guidelines, SOG-06-06 (Standard Hydraulic Practices)

References IFSTA, Essentials of Firefighting, 4 th Edition

 Chapter 12(Fire Hose)

References NFPA Standards

 NFPA 1961(Standard on Fire Hose)    NFPA 1963(Standard for Fire Hose Connections) NFPA 1901(Standard for Automatic Fire Apparatus) NFPA 1962(Care, Use and Service testing of Fire Hose including Coupling and Nozzles)

 

Questions?

Comments?

Concerns?