YGFC FAN COIL UNIT

FACTORY LOCATED IN GUANGZHOU, CHINA

CAPACITY = 300,000 UNITS/YEAR = 1,000 UNIT/DAY!

CERTIFICATION

ISO 9001:2000, GB/T 19002:2000 CERTIFIED FACTORYGB/T 19232:2003 CERTIFIED TEST LAB (ONLY 2 IN

CHINA)

FEATURES

YGFC FAN COIL UNIT

CE (TUV) CERTIFIED

CONFIGURATION: CONCEALED, CABINET, HORIZONTAL,

VERTICAL

COIL: 2 CHOICES, CONVENTIONAL OR DISTRICT COOLING10 SIZES (70-600 L/S, 1-15KW COOLING)DRAIN PAN: DIE-FORMED, ANTI-RUST PAINTED, INSULATEDMOTORS: DIRECT DRIVE, THERMAL PROTECTION, BALL

BEARING

TESTINGCOIL PRESSURE TESTED AT 2400 KPAMOTOR TESTED FOR EARTH LEAK AND CURRENT

YGFC FAN COIL UNIT

SPECIFICATION3 OR 4 ROW COIL, WORKING PRESSURE 1600kPaFILTER: 6mm NYLON1mm GALV.STEEL CASING FOR ADDED NOISE

REDUCTION

INSULATED PAINTED DRAIN PAN10mm COATED FIBREGLASS INSULATED FAN DECK &

COIL SECTION

YGFC FAN COIL UNIT

OPTIONSCASING: FULLY POWDER COATEDFILTER: 25 MM ALUMINUMFINS: HYDROPHILIC, EPOXY COAT, COPPERSTAINLESS STEEL DRAIN PANMOTORS: IP 23 AS STANDARD, 42 & 54 AS OPTION6mm CLOSED CELL INSULATED RETURN PLENUM,

ELECTRIC HEATER

YGFC FAN COIL UNIT

ADVANTAGESCHOOSE FROM 10 MODEL SIZES TO MATCH ROOM

NEED

LOW HEIGHT (250MM) SUITABLE FOR TOWER

BLOCKS

WHISPER-QUIET OPERATIONRESISTANCE TO CORROSIONADAPTABILITY TO STANDARD OR DISTRICT

COOLING APPLICATION

YGFC FAN COIL UNIT

ADVANTAGESEASE OF MAINTENANCELOW RISK OF LEAKS FROM DRAIN PAN AND COIL

CONNECTIONS

LOW RISK OF BEARING WEARLONGER MOTOR LIFE – LONGER UNIT LIFE!ECONOMICAL LIFE CYCLE

DISTRICT COOLING

DefinitionProduce chilled water at a central plantDistribute to buildings for AC needsCharge subscribers based on actual usageBenefitsDiversity

reduced capacity, reduced cost

Large size

$/Ton, 11kV, eff systems & eqpt, life

Containment

maintenance (AC vs WC), noise

Cogeneration and use of waste energy

DISTRICT COOLING

WHERECity Centers: large buildings & loads, premium spaceAirports: large buildings & loads, continuous operationIndustrial Centers: many process loads, reliabilityDESIGNLow flow (1.5 gpm/ton)

high ΔT, small pipes & pumps

Low supply chilled water temperature

smaller AS

Check for laminar flow in FCU

poor cooling

Reynolds number > 4000Ensure appropriate ΔT on airside of heat exchanger

YGFC FAN COIL UNIT

POINTS TO NOTE!THIS IS A ‘HIGH VOLUME’ PRODUCT - SIMPLE

SPECIFICATION ALLOWS LOW COST & SPEEDS UP LEAD TIMES

TARGET LOW END SPEC. PROJECTS, AND SALES TO

DISTRIBUTORS AND END USERS

LESS RANGE OF OPTIONS & SQ’S WHEN COMPARED TO

‘EUROPEAN’ FCU’S

FCU CASING NOT THE MOST ATTRACTIVE!ARE YOU ABLE TO ORDER & HOLD STOCK UNITS??

YGFC FAN COIL UNIT

POINTS TO NOTE!THERMOSTATS & CONTROLS AVAILABLE FROM ASIA

PACIFIC ARE NOT CE CERTIFIED

VALVES ARE NOT FACTORY FITTEDFILTER REMOVAL ON CEILING CONCEALED UNIT IS

DIFFICULT AS IT REQUIRES SCREW REMOVAL

EUROVENT CERTIFICATION WILL BE MADE LATE 2006

YGFC SOFTWARE

YORK DESIGNED, INDEPENDENT OF YORKWORKS

YGFC SOFTWARE

- GENERATES TECHNICAL SCHEDULES…

- GENERATES

WORKS ORDER

YGFC SOFTWARE

ALSO GENERATES… -OPTIMUM FCU

CONTAINERISATION FOR SHIPPING

-CATALOGUE DATA

SHEETS & TECHNICAL SPECIFICATIONS

-PRICE SUMMARY

TECHNICAL DOCUMENTATION PRICING SQ’S & SQ PRICING ORDERS SHIPPING WARRANTY SOFTWARE

WHO TO CONTACT….

James Long ([email protected]), Alan Hinton ([email protected]) Alan Hinton ([email protected]) James Long ([email protected]), c.c. to Alan Hinton ([email protected]) Jackey Que ( [email protected]

), c.c to James Long ([email protected]) Erica Wang ([email protected]) Ding yue ( [email protected]

), c.c to Kevin Lau ([email protected]) Alan Hinton ([email protected])