Transcript `YGFC` FAN COIL UNITS NEW PRODUCTS
‘YGFC’ FAN COIL UNITS
NEW PRODUCTS - 2006
YGFC FAN COIL UNIT
• FACTORY LOCATED IN GUANGZHOU, CHINA
– CAPACITY = 300,000 UNITS/YEAR = 1,000 UNIT/DAY!
• CERTIFICATION
– ISO 9001:2000, GB/T 19002:2000 CERTIFIED FACTORY – GB/T 19232:2003 CERTIFIED TEST LAB (ONLY 2 IN
CHINA)
FEATURES
YGFC FAN COIL UNIT
– CE (TUV) CERTIFIED
– CONFIGURATION: CONCEALED, CABINET, HORIZONTAL,
VERTICAL
– COIL: 2 CHOICES, CONVENTIONAL OR DISTRICT COOLING – 10 SIZES (70-600 L/S, 1-15KW COOLING) – DRAIN PAN: DIE-FORMED, ANTI-RUST PAINTED, INSULATED – MOTORS: DIRECT DRIVE, THERMAL PROTECTION, BALL
BEARING
• TESTING – COIL PRESSURE TESTED AT 2400 KPA – MOTOR TESTED FOR EARTH LEAK AND CURRENT
YGFC FAN COIL UNIT
• SPECIFICATION – 3 OR 4 ROW COIL, WORKING PRESSURE 1600kPa – FILTER: 6mm NYLON – 1mm GALV.STEEL CASING FOR ADDED NOISE
REDUCTION
– INSULATED PAINTED DRAIN PAN – 10mm COATED FIBREGLASS INSULATED FAN DECK &
COIL SECTION
YGFC FAN COIL UNIT
• OPTIONS – CASING: FULLY POWDER COATED – FILTER: 25 MM ALUMINUM – FINS: HYDROPHILIC, EPOXY COAT, COPPER – STAINLESS STEEL DRAIN PAN – MOTORS: IP 23 AS STANDARD, 42 & 54 AS OPTION – 6mm CLOSED CELL INSULATED RETURN PLENUM,
ELECTRIC HEATER
YGFC FAN COIL UNIT
• ADVANTAGES – CHOOSE FROM 10 MODEL SIZES TO MATCH ROOM
NEED
– LOW HEIGHT (250MM) SUITABLE FOR TOWER
BLOCKS
– WHISPER-QUIET OPERATION – RESISTANCE TO CORROSION – ADAPTABILITY TO STANDARD OR DISTRICT
COOLING APPLICATION
YGFC FAN COIL UNIT
• ADVANTAGES – EASE OF MAINTENANCE – LOW RISK OF LEAKS FROM DRAIN PAN AND COIL
CONNECTIONS
– LOW RISK OF BEARING WEAR – LONGER MOTOR LIFE – LONGER UNIT LIFE! – ECONOMICAL LIFE CYCLE
DISTRICT COOLING
• Definition – Produce chilled water at a central plant – Distribute to buildings for AC needs – Charge subscribers based on actual usage • Benefits – Diversity
reduced capacity, reduced cost
– Large size
$/Ton, 11kV, eff systems & eqpt, life
– Containment
maintenance (AC vs WC), noise
– Cogeneration and use of waste energy
DISTRICT COOLING
• WHERE – City Centers: large buildings & loads, premium space – Airports: large buildings & loads, continuous operation – Industrial Centers: many process loads, reliability • DESIGN – Low flow (1.5 gpm/ton)
high ΔT, small pipes & pumps
– Low supply chilled water temperature
smaller AS
– Check for laminar flow in FCU
poor cooling
– Reynolds number > 4000 – Ensure appropriate ΔT on airside of heat exchanger
YGFC FAN COIL UNIT
• POINTS TO NOTE! – THIS IS A ‘HIGH VOLUME’ PRODUCT - SIMPLE
SPECIFICATION ALLOWS LOW COST & SPEEDS UP LEAD TIMES
– TARGET LOW END SPEC. PROJECTS, AND SALES TO
DISTRIBUTORS AND END USERS
– LESS RANGE OF OPTIONS & SQ’S WHEN COMPARED TO
‘EUROPEAN’ FCU’S
– FCU CASING NOT THE MOST ATTRACTIVE! – ARE YOU ABLE TO ORDER & HOLD STOCK UNITS??
YGFC FAN COIL UNIT
• POINTS TO NOTE! – THERMOSTATS & CONTROLS AVAILABLE FROM ASIA
PACIFIC ARE NOT CE CERTIFIED
– VALVES ARE NOT FACTORY FITTED – FILTER REMOVAL ON CEILING CONCEALED UNIT IS
DIFFICULT AS IT REQUIRES SCREW REMOVAL
– EUROVENT CERTIFICATION WILL BE MADE LATE 2006
YGFC SOFTWARE
YORK DESIGNED, INDEPENDENT OF YORKWORKS
YGFC SOFTWARE
- GENERATES TECHNICAL SCHEDULES…
- GENERATES
WORKS ORDER
YGFC SOFTWARE
•ALSO GENERATES… -OPTIMUM FCU
CONTAINERISATION FOR SHIPPING
-CATALOGUE DATA
SHEETS & TECHNICAL SPECIFICATIONS
-PRICE SUMMARY
TECHNICAL DOCUMENTATION PRICING SQ’S & SQ PRICING ORDERS SHIPPING WARRANTY SOFTWARE
WHO TO CONTACT….
James Long ([email protected]), Alan Hinton ([email protected]) Alan Hinton ([email protected]) James Long ([email protected]), c.c. to Alan Hinton ([email protected]) Jackey Que ( [email protected]
), c.c to James Long ([email protected]) Erica Wang ([email protected]) Ding yue ( [email protected]
), c.c to Kevin Lau ([email protected]) Alan Hinton ([email protected])