Motor Control Center Technical Briefs

Download Report

Transcript Motor Control Center Technical Briefs

Bhupesh Das

PV Plus Update

IPB 101

Operator Interface Terminals

PanelView Plus

Operator Interface terminals designed to optimize system development, performance, and efficiency through:     Re-usable development tools Modular components Multiple communication options Advanced graphic features

3

Optimizing System Development

   ViewAnyWare  Common development software Innovative Design   Small package Modular components Protecting Past Investments   PanelView Standard and PanelView ‘e’ file conversion Common cutouts with PanelView Standard, PanelView ‘e’, and RAC6182

4

ViewAnyWare Machine Level Platforms

RSView Studio V3.10

Configuration PanelView Plus* VersaView CE Computers* Runtimes VersaView Computers Windows 2000/XP Runtimes PanelView Plus 400/600 Dedicated MV w/ME Open - Windows CE Open - Windows 2000/XP

*Note: RSView ME runtime included with PanelView Plus and VersaView CE

5

Re-usable Development Tools

   

Common Look & Feel

  Single development environment “RSView Studio” – reduces training Best in Class graphical editor – common objects, navigation and behaviors

Scalability

  Cross platform support - Machine & Supervisory Level HMI Cross OS support - Dedicated, CE, Win 2000/XP

Portability

  Data & application migration – reuse of project components Legacy migration

Interoperability

  Global Namespace via FactoryTalk Direct Referencing (Tagless HMI)

6

Modular Components

PanelView Plus offers component modularity so that design teams can choose the right platform to meet their budget, space requirements and environmental conditions such as:  Display modules (For PanelView Plus 700-1500)  Common logic modules (For PanelView Plus 700-1500)   Communication modules Memory modules (For PanelView Plus 700-1500)

Communications Module (Optional) Communications Module (Optional) Logic Module Display Module Integrated Logic & Display PanelView Plus 700, 1000, 1250, & 1500 7 PanelView Plus 400 & 600

Modularity – Just Enough

For applications with limited budgets and requiring only basic PLC connectivity, PanelView Plus 400 and 600 is an economical option    RS-232 communications Supports DF1 & DH-485 Supports 25 other multi-vendor serial protocols RS-232 communications Flexible USB peripheral support

8

Modularity – Affordable but Flexible

For more distributed or complex applications with networked PLC connectivity, PanelView Plus 400 and 600 offer:  RS-232 communications   Ethernet communications Optional communication modules  DH+    Remote I/O (Single Rack) DH-485 Isolated RS-232 Flexible USB peripheral support Optional Communication Modules Ethernet communications

9

RS-232 communications

Modularity – Optimal Serviceability

   PanelView Plus 700-1500 provides a variety of modularity:  Display sizes from 7” – 15”   Range of memory options  64MB RAM / 32MB Flash  128MB RAM / 128MB Flash Multiple communication options  DH+ / DH-485 / Remote I/O External Compact Flash  ControlNet Allows users to standardize on a base of common components to use across multiple applications Common components can reduce maintenance procedures and inventory costs

10

Replaceable Backlight Optional Communication Modules Replaceable Bezel Ethernet communications RS-232 communications Flexible USB peripheral support

PanelView Plus Innovative Design

OEM Replaceable Label Easy installation with patent-pending mounting levers

(For the PanelView Plus 400 & 600)

Analog Touch Screen Keypad Option Navigation Keys Re-Legendable Function Keys

(For PanelView Plus 600-1500)

11

Protecting Past Investments

  RSView Studio imports the majority of PanelView Standard and PanelView ‘e’ tags and screens Physical migration by retaining common cutouts   PanelView Plus with a larger display drops into the same cutout as smaller PanelView Standard and PanelView ‘e’ Adapter plates when maintaining the display size is preferred

12

Multiple Communication Options

   Preferred HMI for Rockwell Automation Controllers with RSLinx Enterprise and

FactoryTalk

Allows simultaneous communications Supports these Rockwell Automation networks:  DF1      DH-485 Remote I/O DH+ Ethernet/IP ControlNet (For PanelView Plus 700-1500)  KepServer drivers are available for serial and Ethernet protocols for many PLC vendors at no additional charge  Supports the following protocols:

Automation Direct EBC Omron Host Link Automation Direct ECOM DIRECT-NET Omron Process Suite Siemens S5 EtherTRAK GE Ethernet GE Ethernet Global Data GE SNP GE SNPX Mitsubishi A Series Mitsubishi FX Mitsubishi FX Net Modbus Ascii Serial Modbus Ethernet Modbus Serial Modbus Unsolicited Serial Siemens S7-MPI Siemens S7-200 Simatic 505 Serial Simatic 505 Ethernet Simulator Square D TIWAY Host Adapter Uni-Telway User Configurable Driver 13

Optimizing System Performance & Efficiency

The advanced graphic features of RSView Machine Edition maximizes system performance and efficiency allowing the user to customize system views using:  18-bit color graphics     Trending Expressions Data Logging Animation

14

18-Bit Color Graphics

Improve operator comprehension with intuitive graphics and digital photos  18-bit color depth and high quality displays   Pre-configured graphic library  Valves, drives, faceplates, motors, and more!

User library for custom graphics

15

RSView Machine Edition Features

     Trending to monitor real time and historical data Data Logging to log tag values that can be displayed in the historical trend object  Flexible logging options include:  Compact Flash Card   Remote PC Local Drive  Convert datalog file to DBF for use with Excel Security to restrict operator access to specific displays Expressions to perform mathematical or logical calculations

Parameter Files & Pop-up displays 16

Plus…Advanced Diagnose & Optimize Features

  

Alarms

 Pop-up banners, status list and sort    Printing alarms Alarm text to controllers Alarm Filtering

Historical & Real Time Trending

 Visualize variable changes over time 

Data Logging

 To internal memory, Compact Flash card, or a remote PC  Includes x-y plot support View and analyze data later

17

RSView Studio Features

Quickly create commonly used pre-defined objects

• Pushbuttons, numerics, alphanumerics, gauges, bar graphs, list selectors, navigation buttons

Expressions provide greater flexibility for objects

• Arithmetic, logical, if-then-else

Reduce effort of animating HMI screens

• • • • Fill, Color Position, Rotation, Size Visibility Slider

Re-use a single screen with multiple sets of data

• Parameter file passes data to screen objects

18

Additional RSView Studio Features

       Quick test run, which simulates individual displays or entire projects Full-featured Graphics Editor with

powerful editing tools

Flexible editing of object attributes with

Property Page & Panel Editors

Object Explorer provides hierarchy view of objects on a display & convenient editing of grouped objects Graphics Library contains hundreds of graphic objects to drap and drop into your displays Reuse of Tags from RSLogix packages Import graphics developed in other software packages

19

PanelView Plus - Flexible, Powerful, Robust

20

Questions?

Thank-you