CONTENTS
• INVERTER K-SERIES • INVERTER Y SINGLE SPLIT (SERIES I & II) INDOORS OUTDOORS • INVERTER Y MULTI SPLIT
Technical Training
INVERTER K-SERIES
Technical Training
INVERTER K-SERIES
INDOOR
W Btu/h R410A (5WMY-KR) 0.9K
3K 1.4K
5K 2.0K
7K 2.6K
9K 3.2K
11K 3.8K
13K 4.4K
15K 5.8K
20K 8.8K
30K
5WMY10/15 KR
Technical Training
INVERTER K-SERIES
OUTDOOR
W Btu/h R410A (5LCY-ER) 0.9K
3K 1.4K
5K 2.0K
7K 2.6K
9K 3.2K
11K 3.8K
13K 4.4K
15K 5.8K
20K 8.8K
30K
5LCY10/15 ER
Technical Training
INVERTER K-SERIES : Features
High EER / COP of 5WMY
EER European EER Rating COP European EER Rating 2.5 kW 3.42
A 4.06
A 3.5 kW 3.37
A 3.76
A
ECONO Mode Econo Mode is a function that sets a limit for power consumption. This mode is useful for preventing Circuit breakers from being overloaded by the use of multiple air conditioners and other electrical devices. The function is easily activated from the remote controller by pushing the ECONO button.
Technical Training
INVERTER K-SERIES : Features
5 Speed Fan motor, • inclusive of Quiet Mode Super Low Speed @ 22 dBA! Sound Pressure H/M/L/SL (dBA) Cooling Heating 5WMY10KR 40/33/26/22 40/34/28/25 Night Set Mode
This function prevent excessive cooling or heating for your pleasant sleep.
5WMY15KR 41/34/27/23 41/35/29/26
Technical Training
INVERTER K-SERIES : Features
Indoor Air Quality • Titanium Apatite Photocatalytic Air Purifying Filter
Technical Training
INVERTER K-SERIES : Features
Comfort Airflow Mode “Comfortable Mode” prevents direct airflow to users and reduces discomfort air drafts.
When cooling : Flap can be fixed at higher position than the normal cooling operation position.
When heating : Flap can be fixed at lower position than the normal heating operation position and warms feet.
by one touch !
Comfort Mode 0 ° fixed 0 ° 5 ° 45 ° Normal Operation 5~45 ° < Cooling > Normal Operation 15~45 ° 15 ° 45 ° 50 ° Comfort Mode 50 ° fixed < Heating >
Technical Training
INVERTER K-SERIES : Features
Standby electricity saving Without this function, about 6W standby electricity is necessary. By cutting power supply to outdoor unit, necessary standby electricity is reduced to 1 W at the least. This new function corresponds to diversified energy saving needs. Operation standby electricity < Without “Standby Electricity Saving” > < With “Standby Electricity Saving” > 1 W For indoor unit microcomputer 5 W For outdoor unit microcomputer 1 W For indoor unit microcomputer 0 W (Outdoor unit is suspended) Note: In some conditions, for example when temperature is low, outdoor unit runs microcomputer and preheats compressor and thus uses energy. (About 35 W is necessary for preheating)
Technical Training
INVERTER Y SINGLE SPLIT
Technical Training
INVERTER Y SINGLE SPLIT
Product Line Up SERIES I 5WMY-JR 5CKY-ER 5CKY-CR Outdoor Model 5LCY-C Indoor Model 5WMY-J 5CKY-E 5CKY-C 5CMY-E 5CCY-C Outdoor Model 5LCY-D Indoor Model 5WMY-J 5CKY-E 5CKY-C 5CMY-E 5CCY-C SERIES II Outdoor Model 5LCY-E Indoor Model 5WMY-J 5CKY-E 5CKY-C 5CMY-E 5CCY-C 10 10
P P P
30
P P P
15 15
P P P P
40
P P P
5CMY-ER 20
P P P P P
20 25
P P P P
25 5CCY-CR 50
P P P
60
P P
Technical Training
SERIES I
Technical Training
SERIES I
Indoor: 5WMY-JR
W Btu/h R410A (5WMY-JR) 0.9K
3K 1.4K
5K 2.0K
7K 2.6K
9K 3.2K
11K 3.8K
13K 4.4K
15K 5.8K
20K 8.8K
30K
5WMY 10/15/20/25JR
Technical Training
SERIES I
WMY-J Features: High EER/COP performance.
• ALL Models rank A/A or Exceeds!
(W/W) 2.5 kW 3.5 kW 5.0 kW 6.0 kW EER
3.42
3.33
3.31
3.21
COP
3.62
3.62
3.63
3.74
High Quality & Efficiency Daikin DC Inverter compressor High Performance Daikin Inverter Controller 5-speed Step-less Fan operation BioPro IAQ.
New Inverter-only Remote Control
Technical Training
SERIES I
Indoor: 5CKY-CR
W Btu/h R410A (5CKY-CR) 0.9K
3K 1.4K
5K 2.0K
7K 2.6K
9K 3.2K
11K 3.8K
13K 4.4K
15K 5.8K
20K 8.8K
30K
5CKY 10/15/20CR
Technical Training
SERIES I
Outdoor: 5LCY-DR
W Btu/h R410A (5LCY-DR) 0.9K
3K 1.4K
5K 2.0K
7K 2.6K
9K 3.2K
11K 3.8K
13K 4.4K
15K 5.8K
20K 8.8K
30K
5LCY 10/15DR
Technical Training
SERIES I
Outdoor: 5LCY-CR
W Btu/h R410A (5LCY-CR) 0.9K
3K 1.4K
5K 2.0K
7K 2.6K
9K 3.2K
11K 3.8K
13K 4.4K
15K 5.8K
20K
5LCY 20/25CR
8.8K
30K
Technical Training
SERIES I
Outlook
About the same between 5LCY & 5LCX-series 5LCY10/15D Series 5LCX-C Series * 5LCY20/25 will be using the same casing as 5LCX and mass-production by March 2010
Technical Training
SERIES I
Piping Length & Elevation Model 5LCY10DR 5LCX10CR Max. total piping length (m)
15 15
Max. height difference (m)
10 5
Pre-charge for up to piping length (m) Additional charge (g/m)
7.5
20 7.62
20
5LCY15DR 5LCX15CR
15 15 10 5 7.5
7.62
20 20
Technical Training
SERIES I
Control Box
Control box casing using plastic material.
Reactor is mounted on outdoor panels.
Control box is mounted face down.
5LCY-D 5LCX-C Compact & Lighter
Technical Training
SERIES I
Terminal Block
Equipped with 7-segment display to improve serviceability.
To retrieve error code & running parameters.
Technical Training
SERIES I
Thermistors 5LCY-D Series
Outdoor coil Discharge pipe Outdoor air Heat sink Heat sink thermistor to capture heat sink temperature
5LCX-C Series
Outdoor coil Discharge pipe Outdoor air -
Technical Training
SERIES I
Outdoor Fan
Both Y-series and X-series are using variable OD fan speed control by ON/OFF cycle motor.
Variable speed duty cycle in respond to current system load & ambient condition.
5LCY-D Series
6-speed Low ambient -10/15 C
5LCX-C Series
2-speed -
Technical Training
SERIES I
Software and Protection Software Auto restart Over current Over heating 5LCY-D Series
OYLM
5LCX-C Series
OYLM
Technical Training
SERIES I
Control System Compatibility 5LCY-D Series SLM 3 NETWARE 3* G-WAY NIM
× × ×
5LCX-C Series
* Standard handset for CC units, not available yet for wall mounted series.
Technical Training
SERIES II
Technical Training
SERIES II
Indoor: 5CKY-ER
W Btu/h R410A (5CKY-ER) 4.4K
15K 5.8K
20K 8.8K
30K 11.7K
40K 14.6K
17.6K
20.5K
50K 60K 70K
5CKY 28/40/50ER
Technical Training
SERIES II
5CKY-ER Features
Improve Sound Level
• • • New CKY-E series is equipped with a newly-developed turbo fan, which has improved the sound pressure level of the unit significantly. 4 selected fan speeds By selecting the Quiet mode, the sound pressure level can be as low as 27dBA.
Technical Training
SERIES II
5CKY-ER Features
Multi comfort- 3 air swing pattern control
• 3 selected air swing pattern to suit different requirements
Swing mode selection method through wireless handset:
-Press SWING button for 4 seconds to enter field setting mode. While in field setting mode, show only SETTING MODE -Press temperature + or – button to select SWING MODE rotation from SWING MODE 1 to SWING MODE 3 -If no mode changes within 4 seconds, unit will operate according to the selected SWING MODE
Technical Training
SERIES II
5CKY-ER Features
Optimum Air Discharge
• • Combining 4 ways air discharge and large discharge area on each side Additional of the automatic air swing help to further to evenly distribute conditioned air to every corner of the install area.
Technical Training
SERIES II
5CKY-ER Features
Modern & Elegant Panel Design
• • • Unique “Round” side contour Side LED light location Promote Uniform Installation • Same dimension (all capacity) • Rotate able intake grill
Allow 90
°
Rotation
Technical Training
SERIES II
5CKY-ER Features
Lower Height model
2 uniform height base on different capacity Small fan motor Compact body design
A B C
Technical Training
SERIES II
5CKY-ER Features
Built-In high head drain pump
Built-in high head drain pump 700mm head.
A safety float is incorporated in the drain pump to monitor its water level
Technical Training
SERIES II
Indoor: 5CMY-ER
W Btu/h R410A (5CMY-ER) 4.4K
15K 5.8K
20K 8.8K
30K 11.7K
40K 14.6K
17.6K
20.5K
50K 60K 70K
5CMY 28/40/50ER 5CMY 62CR
Technical Training
SERIES II
5CMY-ER Features
Ceiling and floor installation option
-To install below the ceiling -To mount at low wall position
Easy Serviceability
- Control box, motor and blower can be access easily by just pulling down the filter rail.
Ceiling installation type Standing installation type
Technical Training
SERIES II
5CMY-ER Features
Negative ion generator
-To increase the amount of negative ion in the air conditioning area, creating more refreshing environment
Automatic air swing
-The motorized louver enables the air flow to be evenly distributed.
-At the same time, negative ion will be released to provide quality air
Technical Training
SERIES II
5CMY-ER Features
Flexible installation
-Unit is designed to work with high pressure head drain pump (optional). -To offer flexibility for installation on condensate drain pipe -Drain pump comes with a high head and is incorporate with the float switch as safety protection
Technical Training
SERIES II
5CMY-ER Features
Fresh air option
-The unit is designed to draw in fresh air from outdoor. A fresh air knocked out holes is designed within the unit itself to provide better ventilation.
Technical Training
SERIES II
Indoor: 5CCY-CR
W Btu/h R410A (5CCY-CR) 4.4K
15K 5.8K
20K 8.8K
30K 11.7K
40K 14.6K
17.6K
20.5K
50K 60K 70K
5CCY 28/38/50/60CR
Technical Training
SERIES II
5CCY-CR Features
Microprocessor controlled
-Offer comfortable room conditions according to the needs of the user -Provide protection to components of the air conditioning unit against any fault through its control algorithm
Optional duct accessories
* Available for 5CCY10-25CR only.
Technical Training
SERIES II
5CCY-CR Features
Auto random restart
-Automatically restart according to the last state setting condition when power resumed -Option is provided to cancel this features
Double protection drainage system
-Primary drain pan: high thermal insulation material and molded in gradient for better condensate water drainage Secondary drain pan: “built in” to standard unit offers extra protection against possible water leaking problems
Technical Training
SERIES II
Outdoor: 5LCY-ER
W Btu/h R410A (5LCY-ER) 4.4K
15K 5.8K
20K 8.8K
30K 11.7K
40K 14.6K
17.6K
50K 60K 20.5K
70K
5LCY 30/40/50/60ER
Technical Training
SERIES II
Piping Length & Elevation Model 5LCY30ER 5LCY40ER 5LCY50ER 5LCY60ER Max. total piping length (m)
50 75 75 75
Max. height difference (m)
30 30 30 30
Pre-charge for up to piping length (m) Additional charge (g/m)
30 50 30 30 50 50 30 50
Technical Training
SERIES II
Control Box
Control box is vertically mounted facing out of the casing.
Main & inverter PCB
Technical Training
SERIES II
Others OD fan Compressor type Software Auto restart Over current Over heating 5LCY30ER
DC motor Swing Daikin
5LCY40-60ER
DC motor Scroll Daikin
Annual Technical Training 2009
SERIES II
Control System Compatibility Accessories SLM 3 Compatibility
×
NETWARE 3* G-WAY
×
NIM
× * Standard handset for CC units, not available yet for wall mounted series.
Annual Technical Training 2009
INVERTER Y MULTI SPLIT
Annual Technical Training 2009
INVERTER Y MULTI SPLIT
Indoor Unit Outdoor Unit 5WMY-JR 5CKY-ER 5CKY-CR 5CCY-CR 5CMY-ER 5MSY20/25/30BR Multi Split 5MSY20BR (1-2 Indoors) 5WMY-J 5CKY-C 5CMY-E 10
P P
5MSY25BR (1-3 Indoors) 5CCY-C 5WMY-J 5CKY-C 5CMY-E
P P P
5CCY-C 5WMY-J
P P
5MSY30BR (1-4 Indoors) 5CKY-E 5CKY-C
P
5CMY-E 5CCY-C
P P P P P P
15
P P P P
20
P P P P P P P P
Technical Training
INVERTER Y MULTI SPLIT
5MSY-BR Features
• •
Flexibility in Application & Installation
Available for double, triple, and quadruple indoor connections.
Different types of indoor units in the same system.
• •
Better Energy Saving
Combination of improved efficiency compressor and intelligent electronic controls.
Achieved class A/A based on European Energy Efficiency Class ratings.
Technical Training
INVERTER Y MULTI SPLIT
Outlook
About the same between 5MSY & 5MSX-series 5MSY-B Series 5MSX-A Series
Technical Training
INVERTER Y MULTI SPLIT
Piping Length and Elevation Model 5MSY20BR Max. total piping length (m)
50
Single indoor max. piping length (m) Max. height difference (m)
25 15
Pre-charge total piping length (m) Pre charged (kg)
10 2.0
Additional charge (g/m)
20
5MSX20AR
30 20 5 20 1.65
20
5MSY25BR 5MSX25AR
60 50 25 20 15 5 20 40 2.6
2.32
20 20
5MSY20BR 5MSX20AR
60 60 25 20 15 5 20 40 2.6
3.39
20 20
Technical Training
INVERTER Y MULTI SPLIT
Control Box
OEM Daikin.
Control box casing using plastic material.
Control box is mounted face down.
5MSY-B Series 5MSX-A Series Compact & Lighter
Technical Training
INVERTER Y MULTI SPLIT
Terminal Block Error Diagnosis No. of LED Location 5MSY-B Series
5 Next to terminal block
5MSX-A Series
2 Inside control box 5MSY-B Series 5MSX-A Series
Technical Training
INVERTER Y MULTI SPLIT
Thermistors
5MSY has more feedback where each indoor will be equipped with a gas pipe and liquid pipe thermistors.
5MSY-B Series
Outdoor coil Discharge pipe Outdoor air Gas pipe x no. of indoor unit Liquid pipe x no. of indoor unit Heat sink
5MSX-A Series
Outdoor coil Discharge pipe Outdoor air Gas pipe x 1 Liquid pipe x 1 -
Technical Training
INVERTER Y MULTI SPLIT
Outdoor Fan
Similarly, 5MSY-B series and 5MSX-A series are equipped with variable speed motor to cater for different system load & ambient condition.
5MSY-B Series
Reluctance DC motor Low ambient 0 C
5MSX-A Series
AC tap speed motor (fixed 3 speeds) -
Technical Training
INVERTER Y MULTI SPLIT
Other Components Compressor Expansion device 5MSY-B Series
Swing type EXV
5MSX-A Series
Scroll type EXV Swing compressor • • Different compressor driving method.
Has a higher EER, lower vibration & noise and higher durability.
Technical Training
INVERTER Y MULTI SPLIT
Software and Protection Software Wiring error-check Priority room setting Over current Over heating 5MSY-B Series 5MSX-A Series
Daikin Longertech × ×
Technical Training
INVERTER Y MULTI SPLIT
Wiring Error Check
Designed to provide convenience for the system to correct wiring errors itself.
For unclear local wiring in the case of buried/hidden piping.
This function works by letting refrigerant flow from port A and on onward. The indoor coil temperature is detected one by one to check for matching between the piping and wiring.
If wiring is corrected or change a new controller, wiring check has to be carried out again.
Technical Training
INVERTER Y MULTI SPLIT
Wiring Error Check
For example: If wiring from Port A is correctly connected to Room A, but piping from Port B instead.
After self-correction, when unit is turned ON, OD will change the add in memory so that EXV A is link to Port B.
Room A Piping connected to Port B Room B Piping connected to Port A
Technical Training
INVERTER Y MULTI SPLIT
Wiring Error Check
Press SW3 button to activate wiring check function: • • • The red LEDs will start blinking one after another.
The compressor is set to run at fix frequency.
Wiring to each ID unit is checked in sequence.
It takes 10~15min to complete the check and correction.
Result • • Red LEDs blinking in sequence – self correction complete, unit ready to run.
All LEDs blinking together – fail to self correct, recheck wire and piping.
This function is subjected to following conditions: • • • • After unit is first turned ON, need to wait for about 30 seconds for system initialization.
OD ambient > 5 C.
To complete 3 minutes standby after unit stops.
Indoor units are not having any other problem.
Technical Training
INVERTER Y MULTI SPLIT
Priority Room Setting
Allow user to set a particular room which takes precedence over the operation mode of other rooms.
For example, if Room A is the priority room, when COOL mode is selected in Room A while Room B, C & D are operating in the following mode:
Operation mode in Room B, C & D Status of Room B, C & D
COOL or DRY or FAN HEAT AUTO Current operation mode is maintained The unit enters Standby Mode. Operation resumes when Room A unit stops operating.
If the unit is set to COOL mode, operation continues.
If set to HEAT mode, it enters Standby Mode.
Operation resumes when Room A unit stops operating.
Technical Training
INVERTER Y MULTI SPLIT
Priority Room Setting
This setting must be done when the unit is first installed.
Make sure setting is only done for 1 room.
Slide SW4 dip switch to the ON side for the corresponding indoor unit to be set as priority room.
Technical Training
INVERTER Y MULTI SPLIT
Control System Compatibility SLM 3 NETWARE 3* 5MSY-B Series
×
5MSX-A Series
G-WAY
×
NIM
× * Standard handset for CC units, not available yet for wall mounted series.
Technical Training
HANDSET
Wireless handset for 5WMY-K Series
Technical Training
HANDSET
Existing handset G15 G17 G18 Netware 3
Standard handset for CC units only
Technical Training
HANDSET
New wireless handset GS01 GS02
For mass production in February 2010
Technical Training
THE END