Base Band Standardization

Download Report

Transcript Base Band Standardization

TMDE Program
Life Cycle Conference
Modernization and
Calibration Measurement
Requirement Summary
CMRS
Greg Hogan
NSWC Corona Det Seal Beach
Life Cycle Stages
•
TMDE Program
Life Cycle Conference
Technical Measurement Requirement
Developed from Prime System requirements
•
Contracting/Active Procurement
Working with Industry to get best value
•
Warranty Coverage
Included in contract negotiation, ideally 3-5 years if available
•
Post-Warranty Support
RCC or OEM, most logistically efficient
•
•
Legacy Support
Designated Overhaul Point establishment and/or ‘Fly-tilFail’ with technology back-up or alternative/shift
Obsolescence
If requirement still exists, then process recycles
TMDE Program
Life Cycle Conference
Known Life Cycle BITRs
(Bumps In The Road)
Technical Measurement
Requirement Definition
System developmental lead
time may be insufficient to
support fielding of TMDE in
time for deployment schedules
Obsolescence
DRMO may not be option if
capability still required but no
longer supported by industry
Legacy Support
Commercial & DoD
infrastructure capabilities may
not exist
Contracting and Procurement
Technology may no longer be
available or cost effective
Warranty Coverage
May not be of sufficient duration,
cost effective, or OEM may not be
willing to accept risk
Post-Warranty Support
Maintainability of technology
may be proprietary/unique
TMDE Program
Life Cycle Conference
Activity Interaction
RMC
Calibration
Centers
INPUT
FEEDBACK
NAVSEA TMDE
TYCOMS &
FLEET REPS
RMCs
(Subject Matter
Experts)
PS/E
Acquisition
Programs
Engineering & Lifecycle
Logistics Team
Individual
System
Assessment
Grouped
System
Requirements
(Measurement Requirements)
PS/E
ISEAs
SUPPLY
(Purchase
Description and
Contract Award)
Defined
Measurement
Disciplines
(Functional Groups)
Categorized
Measurement
Requirements
(SCATs)
TMRs
Functional Groups
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
Signal Generator
Digital Multimeters
Baseband Generator
Synchro Resolver
Spectrum Analyzer
Calibrator
Logic Analyzer
Oscilloscope
Voltmeter
Frequency
LAN/WAN
Telcomm Analyzer
Power Supply
Bit Error Rate Tester
Comm Analyzer
Recorder
Insulation Breakdown
Power Analyzer
Component Test
Impedance Matcher
Field Strength
Noise
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
Radar Test Set
Modulation Analyzer
Probe
Power Meter
Attenuator
Fiber Optics
Distortion
Data Analyzer
Electrical Safety
Network Analyzer
Resistor
Scalar Analyzer
Photo Tachometer
Resistance
Capacitor
Amplifier
Humidity
Dummy Load
Temperature
Transformer
Time/Freq-Domain
Reflectometry
TMDE Program
Life Cycle Conference
44.
45.
46.
Ph
Phase Sequence
Audio Analyzer
47.
48.
49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
Sound Level
Termination
Data Acquisition
Modulator
Adapter
Coupler
Detector
Divider
Filter
Conductivity
Earth Ground
Echo Box
Isolator
Battery Analyzer
PCB Test
Impedance
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
Vibration
Oxygen
Switch
Potentiometer
Mixer
Power Limiter
Antenna
Inductor
Torque
Earth Ground
Signature Analyzer
Teletype
Monitor
TMDE Program
Life Cycle Conference
Obsolescence Issues
•
•
•
•
•
Model obsolete without immediate
direct replacement.
Model no longer on contract.
OPN requirements forefront of
identifying obsolete GPETE.
Conflicting equipment availability
reports.
Vendors not being proactive in
reporting model obsolescence.
Past Year Efforts
SCAT_CD
MOD_DESCP_ABBP_TX
4017
METER RADIATION NBM-520+2 PRB
4019
METER RADIATION NBM-520+4PRBS
4025
ANALYZER LOGIC 102 CH 100MHZ
4115
POWER SUPPLY 50VDC 1.5AMPS
4122
OHMMETER HI-RESOLUTION 2K OHMS
4236
METER CLAMP-ON AC 1000A 700V
4245
MULTIMETER 3.5 DGT AC,DC 1000V
4249
MULTIMETER 4.5 DGT AC/DC 1000V
4306
OSCILLOSCOPE FOUR TRACE 400MHZ
4553
TESTER SEMICONDUCTOR IC
4584
ANALYZER VOICE FREQ 42.5+425HZ
5359
TORQUE CALIBRATOR 0-800FT-LB
4541
MEGOHMMETER 0-5000V 100GOHM
4465
LAN CABLE TESTER
4405
GENERATOR, FUNCTION
TMDE Program
Life Cycle Conference
In Progress
SCAT_CD
MODEL DESCPRIPTION
4070
SYNCHRO TESTER
60+400HZ
4195
VOLTMETER 0DB/1V
100U-1000V
4262
METER DEVIATION FM 4-1000MHZ
4290
TIME DOMAIN REFLECTOMETER
4298
TIME DOMAIN REFLECTOMETER
4341
ANALYZER SPECTRUM 99HZ-1800MHZ
4344
ANALYZER DISTORTION
4362
GENERATOR FM/AM 50KHZ- 550MHZ
4363
GENERATOR AM/FM 9KHZ-2GHZ
4473
ANALYZER ANTENNA 2-1600 MHZ
4475
ANALYZER NETWORK 10MHZ-110GHZ
4659
TRANSFORMER ISOLATION 4:1 5KHZ
4734
ANALYZER SPECTRUM .1- 100KHZ
4940
POWER METER PK 0.1-18.0GHZ
200KHZ
TMDE Program
Life Cycle Conference
Upcoming
•
TMDE Program
Life Cycle Conference
In process to evaluation next obsolescence SCAT codes
for review. Possible candidates.
1. SCAT 4349 Audio Analyzer
2. SCAT 4466 Network Analyzer
3. SCAT 4591 Bit Rate Error Tester
4. SCAT 4567 Optiview II Network Analyzer
5. SCAT 4573 Network Analyzer
6. SCAT 4310 OTDR SM
7. SCAT 4318 OTDR MM
8. Fleet Input ___
CMRS
TMDE Program
Life Cycle Conference
•The Calibration and Measurement Requirements Summary
is a form used to document the measurements O-Level
maintainers could be required to make on a specific Prime
System, and to calculate the test equipment that will be
required to support those measurements.
• Actual Prime System measurements are defined:
Category
I
• Volts, Amps, MHz, RPM, etc.
• Required accuracies
• Unique conditional requirements (rare)
Category
II
• Sufficiently capable test equipment is matched to
each measurement using 4-to-1 Test Accuracy Ratio
Category
III
• Sufficiently capable cal standard or procedure is
matched to the test equipment listed (also 4:1 TAR)
CMRS Responsibilities
ISEAs/PEOs
maintain
Category I
Data only
(Prime System)
TMDE Program
Life Cycle Conference
NAVSEA TMDE
Team will maintain
Categories II and III
(Test Equipment and
Cal Standards)
CMRS Documentation
TMDE Program
Life Cycle Conference
Once Prime System
measurement requirements
(Category I) are documented,
NAVSEA completes remainder
of CMRS. ISEA is then only
responsible for updating Olevel maintenance parameters
when necessary.
Requirement
TMDE Program
Life Cycle Conference
Consolidation
NAVSEA uses consolidated
CMRS data for all serviced PS/E
to develop the best match of
GPETE requirements to cost.
Prime System
Measurement
Parameter
ISEAprovided
Category I
data
Meas 1 (Volts)
Meas 2 (Acc)
Meas 3 (Res)



Meas n
PS/E
#1
PS/E
#2
PS/E
#n
System 1
System 2
System n
850 Vdc
4%
< 3.4 V



795 Vdc
5%
<4V



815 Vdc
10 %
< 8.2 V



The Bottom Line:
TMDE Program
Life Cycle Conference
Make use of GPETE whenever possible.
• Once an ISEA completes the Category I data portion of the
CMRS, NAVSEA then calculates and completes Category II and
III. The complete CMRS for each system is then validated by
the ISEA. Once validated, the responsibility to maintain a
sufficiently capable and reliable inventory of GPETE and
calibration standards rests with NAVSEA 04RM.
• Assuming the O-Level maintenance requirements for a given
system do not change, the only further ISEA action in support of
CMRS is to keep POC data current.
• NAVSEA will advise ISEAs when compatibility or technology
advance/obsolescence compels a change in Category II
equipment, and will resolve any needed shifts with the ISEA.
Over 120 CMRS completed
to date
AN-BYK-6(V)1 CMRS
AN_BYH-1 CMRS
AN_BST-2 Cmrs form
BSR-1 Cmrs Template
AN-BSQ-9(V)4 CMRS
AN_BSQ-9(V) CMRS
AN_BRA-24 CMRS
AN_BQQ-10(V)4 CMRS
BLQ-10 CMRS
AN_APX-118 Cmrs
AN_USQ-172(V) CMRS
BQH-9V1 Cmrs
AN_SYQ-27 CMRS
AN_SXY-1 CMRS
AN_SSX-1 CMRS
AN_SSQ-137(V) CMRS
AN_SMQ-11D & E CMRS
AN_SSH-9 CMRS
AN_SSH-6 CMRS
AN_SPQ-9 CMRS
AN_SSW-2 CMRS
TMDE Program
Life Cycle Conference
TMDE Program
Life Cycle Conference
Questions??
Greg Hogan
[email protected]
562 626-7192
DSN 873