Spyder® Introduction

Download Report

Transcript Spyder® Introduction

Spyder® Introduction
Agenda
• Introductions
• Review Spyder Hardware, Software & Accessories
• Live Product Demonstration
• Spyder Tool
- Physical Point Programming
- Network Point Programming
- Logic Programming
- Simulation
- Commissioning / Downloading / Alarms & Diagnostics
• Spyder Application Library
- Library Migration
• Spyder Venom Tool
2
Best Practices
ZIO review
Multi-controller & Plant Applications
VAV Balancing
3
Guy Zebrick
• Environmental Combustion and Controls division
• Sales Representative / Contractor Support Specialist
• 20+ Years Honeywell
• Branch Commercial Construction Technician
• Branch Project Manager
• Branch Application / Lead Application engineer
• Branch system sales
• Contractor Support / Product specialist
4
Spyder Controller Features
Integrated Honeywell Actuator
Reduce installation costs. AC
synchronous actuator increases life
of the controller and reduces life
cycle costs
DC Power Supply
Power external field devices
without having to add
additional power sources.
Saves money and time.
Integrated On-board
Precision Pressure Sensor
Floating Actuator Housing
Actuator can float inside
housing to increase life due
to damper shaft run-out
Programmable
Whatever you need Spyder
can be programmed to solve
the problem.
Actuator De-Clutch
Removable Terminal Blocks
Hard to reach places are easy
to deal with.
Sylk Bus
A two wire, polarity insensitive
bus that provides both 18 Vdc
power and communications
between a Sylk-enabled sensor
and a Sylk-enabled controller.
5
Network Jack and Service Pin
Easy access network Jack and
service pin for quick installation
and easy service.
Color Coded Inputs and Outputs
Reduce wiring errors and speeds up
troubleshooting.
Fast Digital Pulse Meter
• One Universal Input (UI-1*) is user selectable as a
fast digital Pulse Meter
• Pulse meter/Counter Input specification
- Pulse input specifications:
- Max. frequency: 15Hz (54,000 pulses per hour)
- Min. pulse width: 20ms (debounced)
- Max. chatter: 5ms
6
Spyder VAV Controller with Actuator
Controller
Model
Programmable
Type
Protocol
UI
DI
AO
PVB6436AS
VAV
BACnet
MS/TP
6
4
3
6
YES
YES
PVL0000AS
VAV
LonWorks
0
0
0
0
YES
YES
PVL4022AS
VAV
LonWorks
4a
0
2
2
YES
YES
PVL6436AS
VAV
LonWorks
6
4
3
6
YES
YES
• 2 Digital Outputs
reserved for Integrated
Actuator
• Integrated Pressure
Sensor
7
Velocity
Pressure
Series 60
Sensor
Floating
DO (Microbridge) Actuator
Spyder VAV Controller w/o Actuator
Programmable
Type
Protocol
UI
DI
AO
DO
Velocity
Pressure
Sensor
(Microbridge)
PVB6438NS
VAV
BACnet
MS/TP
6
4
3
8
YES
NO
PVL4024NS
VAV
LonWorks 4a
0
2
4
YES
NO
PVL6438NS
VAV
LonWorks
6
4
3
8
YES
NO
Controller
Model
• Integrated Pressure Sensor
8
Series 60
Floating
Actuator
Spyder Unitary Controller
Controller
Model
Series 60
Floating
Actuator
Programmable
Type
Protocol
PUB6438S
Unitary
BACnet
MS/TP
6
4
3
8
NO
NO
PUL1012S
Unitary
LonWorks
1a
0
1
2
NO
NO
PUL4024S
Unitary
LonWorks
4a
0
2
4
NO
NO
PUL6438S
Unitary
LonWorks
6
4
3
8
NO
NO
UI DI AO DO
• Extended Temperature Rating
9
Velocity
Pressure
Sensor
(Microbridge)
BACnet MS/TP
LON
Programmable Unitary Control
Programmable
Unitary Controllers
Programmable Unitary Controller
• Extended Temperature Rated -40° F
(-40° C) to 150° F (65.5° C)
Programmable VAV
Controllers with Actuator
Programmable Variable Air Volume Controller
• Integrated actuator
• Integrated on-board pressure sensor
Programmable VAV
Controllers w/o Actuator
Programmable Variable Air Volume Controller
• Integrated on-board pressure sensor
PUL1012S – LonWorks
Inputs
• 1 universal input
• 0 digital inputs
Outputs
• 1 analog output
• 2 digital outputs
PVL0000AS – LonWorks
Inputs
• 0 universal inputs
• 0 digital inputs
Outputs
• 0 analog outputs
• 0 digital outputs
PVL4024NS – LonWorks
Inputs
• 4 universal inputs
• 0 digital inputs
Outputs
• 2 analog outputs
• 4 digital outputs
PUL4024S – LonWorks
Inputs
• 4 universal inputs
• 0 digital inputs
Outputs
• 2 analog outputs
• 4 digital outputs
PVL4022AS – LonWorks
Inputs
• 4 universal inputs
• 0 digital inputs
Outputs
• 2 analog outputs
• 2 digital outputs
PVL6438NS – LonWorks
Inputs
• 6 universal inputs
• 4 digital inputs
Outputs
• 3 analog outputs
• 8 digital outputs
PUL6438S – LonWorks
Inputs
• 6 universal inputs
• 4 digital inputs
Outputs
• 3 analog outputs
• 8 digital outputs
PVL6436AS – LonWorks
Inputs
• 6 universal inputs
• 4 digital inputs
Outputs
• 3 analog outputs
• 6 digital outputs
PVB6438NS – BACnet
Inputs
• 6 universal inputs
• 4 digital inputs
Outputs
• 3 analog outputs
• 8 digital outputs
PUB6438S – BACnet
Inputs
• 6 universal inputs
• 4 digital inputs
Outputs
• 3 analog outputs
• 8 digital outputs
PVB6436AS – BACnet
Inputs
• 6 universal inputs
• 4 digital inputs
Outputs
• 3 analog outputs
• 6 digital outputs
New Licensing Scheme
• The Spyder Tool checks the license for features
- As of Spyder Tool 4.X and later
• There are two Spyder features
- SpyderProgrammable for the Lon Spyders
- SpyderBACnetProgrammable for the BACnet Spyders
• Spyder features are only available on WEBS branded
JACE’s and Supervisor Engineering Demo’s
- W-ENG-AX-DEMO
11
Spyder-ILC
• The Spyder-ILC is an individually licensed controller
- Spyder-ILC controllers will accept a download from the
Spyder Tool regardless of the brand of workstation/JACE
- In other words, features within the license are ignored
• The Spyder-ILC’s have the same OS number with an
“-ILC” suffix
- Example: PUL6438S-ILC, PVB6436AS-ILC, PVL4022AS-ILC
• 20% adder per Spyder-ILC for licensing fee
- No one else in the industry offers a programmable controller
that can be programmed on ANY AX front end!
• Like all Spyders, the ILC can only be sold to
Honeywell ACS or ACI contractors
12
Scenario – WEBS Brand JACE
13
WEBS Brand Workbench
WEBS Brand JACE
Spyder Feature
Honeywell Spyder
3rd Party Brand Workbench
WEBS Brand JACE
Spyder Feature
Honeywell Spyder
Scenario – WEBS OPEN Brand JACE
ANY Brand Workbench
WEBS “OPEN” Brand JACE
Spyder Feature
Honeywell Spyder
Not Typical
ANY Brand Workbench
14
WEBS “OPEN” Brand JACE
Spyder Feature
Honeywell Spyder-ILC
Scenario – 3rd Party JACE
ANY Brand Workbench
ANY Brand Workbench
15
3rd Party Brand JACE
3rd Party Brand JACE
Honeywell Spyder
Honeywell Spyder-ILC
Scenario – No JACE
WEBS Brand Engineering
Demo Supervisor
Honeywell Spyder
3rd Party Brand Workbench
Honeywell Spyder
ANY Brand Workbench
16
Honeywell Spyder-ILC
Scenario – Existing Support
• Existing WEBS job needs to be expanded
- 1. Keep existing workbench and tool; add Spyders as
needed
 License change doesn’t affect a job already installed
- 2. Get new license with correct Spyder Features
 If using 403 or 545, the appropriate feature is needed
• Existing job with 3rd party JACE and Spyders, needs
to be expanded
- 1. Keep existing workbench and tool; add Spyders as
needed
 License change doesn’t affect a job already installed
- 2. Upgrade to latest Spyder Tool and use ILC to expand
 Previous Spyders must be brought in as 3rd party devices and you
won’t be able to download to them
17
Freely Programmable
• Just determine your requirements, then program
Spyder to control it all
18
Spyder Palette
19
Application Library
21
Program Simulator and Debug Mode
23
Macros
25
Adaptive Integral Algorithm
• Honeywell’s Adaptive Integral Algorithm (AIA)
Control is the most accurate control available for
space control applications
27
Model Numbers
P VL6436 AS
S – Sylk Bus
P – Programmable
A – With Actuator
N – Without Actuator
U – Unitary
V – VAV
L – LON
B – BACnet
Number of available
Digital Outputs
Number of
Universal Inputs
Number of
Analog Outputs
Number of
Digital Inputs
28
Spyder Lon Specific Details
• Free Topology Transceiver (FTT)
- High-speed 78 kilobit communications network
• Function Blocks
- 200 Function Blocks max per controller
• Lon Network Variables
- 240 total NV’s per controller
 20 Mandatory NVs
 7 Fixed NVs
 213 User Defined NVs
• Support for up to 120 controllers per LonWorks
channel
29
Spyder BACnet Specific Details
• BACnet MS/TP LAN communication network
- Capable of baud rates between 9.6 and 115.2 kilobits
• BTL B-ASC
- BACnet Testing Laboratories B-ASC (BACnet Application
Specific Controller)
- Certification Testing in process
• BACnet PICS (Protocol Implementation
Conformance Statement)
- Refer to the PICS for information on:
 BIBBs – BACnet Interoperability Building Blocks
 BACnet Device Objects
• Support for up to 30 controllers per BACnet MS/TP
LAN Segment
30
Spyder FAQ’s
• Should I use a Spyder if the current XL10 meets the
sequence or requirements?
Depends on application
• Do you want to order the Spyder with Actuator when
you need to separate the actuator and controller?
NO
- What Actuators are recommended for use with the
Spyder VAV controllers without Actuators?
ML6161,
ML6174,
MN6105
31
Architecture
Internet
WEB Station
WEB Browser
WEB Browser
HTTP, XML, BACnet, SNMP, oBIX
WEB-600
WEB-600
Spyder Lon
34 pt I/O
Video Monitoring
and Control
Spyder
BACnet
SEC-H-600
RS-485
RS-485
Spyder Lon
Spyder
BACnet
Spyder Lon
Intrusion
Keypad/Display
T7350
CVAHU
UV
Spyder
BACnet
Lighting
Control
32
Security
Elevator Control
Access Control
Time and Attendance
Sylk™ Bus
• Sylk is a two wire, polarity insensitive bus that provides
both 18 Vdc power and communications between a
Sylk-enabled sensor and a Sylk-enabled controller
• Devices
- Zio LCD Wall Module
 TR70
 TR70-H
• Future
- TR20 Series
- Sylk IO
 Addressing the combined needs of the
Building Automation and Field Device team
34
TR20 Series Wireless Overview
• Point to Point
- Direct replacement for a wired sensor
- Can be used with Spyder, XL10, T7350 thermostats,
SuitePRO
- Not compatible with Commercial VisionPRO &
CommercialPRO thermostats
Receiver
• Two Sensor options
- With temperature only
 TR21-WK kit or TR21-WS sensor only
- With temperature, setpoint knob, and override button
 TR23-WK kit or TR23-WS sensor only
• On board signal strength indicator
- No need for diagnostic tool
• Beta in progress – Thank You!
Wireless sensor
Replace a wired sensor, without the wires!
35
Noteworthy Installations
• Prairie View School District, Saskatchewan
36
Noteworthy Installations
• Target Field (Twins Stadium) - Minneapolis
37
Noteworthy Installations
• ACS Headquarters – Golden Valley
38
Noteworthy Installations
• Adelphia Labs, New Jersey
39
Noteworthy Installations
• Vectura Pharmaceutical, United Kingdom
40
Noteworthy Installations
• Claridges Hotel, Delhi
41
Spyder Tool Demonstration
42
www.honeywell.com