FALL PROTECTION
GA Tech Safety and Health Consultation Program
INTRODUCTION
This training information has been prepared by the Georgia Tech Safety and Health
Consultation Program with the technical collaboration of Mr. Juán C. Rodriguez and
under the sponsorship of OSHA. Its content may be copied and distributed for free. The
Georgia Tech’s Safety and Health Consultation Program requests it be acknowledged as
the source of this information. The authors believe that all information contained in this
training is accurate; however, this is not an official OSHA publication and has not been
revised or approved by OSHA. The user should be aware that the recommendations
provided in this training do not replace any OSHA standard or regulation.
Georgia Tech Safety and Health Consultation Program
Georgia Tech Research Institute
260 14th Street, Fourth Floor
Atlanta, GA 30332-0837
Voice :(404) 407-7431
FAX :(404) 407-8275
Web http://www.oshainfo.gatech.edu
Georgia Tech Safety and Health
Consultation Program
SUBPART M 1926.500
GA Tech Safety and Health Consultation Program
Effective Date: February 6th, 1995
GA Tech Safety and Health Consultation Program
Duty to have fall protection
Protection required when working at 6 feet or higher
Walking/working surfaces shall be inspected before
employees begin work activities
Employees shall be allowed to work only on those
surfaces which have the requisite strength to withstand
their weight
GA Tech Safety and Health Consultation Program
Strong enough surfaces
GA Tech Safety and Health Consultation Program
SCOPE AND APPLICATION
Subpart M sets forths criteria for all fall protection
hazards, except:
Section L - Scaffolds
Section N – Cranes and derricks
Section R – Steel erection work in buildings
Section S – Tunneling operations
Section V – Electric transmission and distribution lines
Section X – Stairways and ladders
GA Tech Safety and Health Consultation Program
Fall Protection is required when…
Unprotected (open) sides
and edges
Leading edge work
Dangerous equipment
Overhand bricklaying
Steep-slope roofs
Residential construction
Holes
Working/walking surfaces
Formwork
Excavations and wells
Precast concrete erection
Wall openings
Low-steep roofs
GA Tech Safety and Health Consultation Program
Sloping roof
GA Tech Safety and Health Consultation Program
Hole
GA Tech Safety and Health Consultation Program
Covered Holes
GA Tech Safety and Health Consultation Program
Sloped Roof
GA Tech Safety and Health Consultation Program
Protection from falling objects
Each exposed employee shall wear a hard hat
Employers must prevent objects from falling from
higher levels (which could strike employees below)
by using all necessary measures
GA Tech Safety and Health Consultation Program
Hard hats
GA Tech Safety and Health Consultation Program
Wearing hard hats
GA Tech Safety and Health Consultation Program
Fall Protection Systems:
criteria and practices...
(a) Guardrails
Top edge height of top rails shall
The midrail shall withstand a
be between 39" and 45"
Midrails shall be installed
between the top edge of the
guard rail and the
walking/working surface
Openings between rails shall
not be more than 19" apart
The top rail edge shall
withstand a force of at least 200
pounds
force of at least 150 pounds
Wire rope shall be flagged and
shall not deflect more than 3"
Frequently inspect wire ropes
No rail material smaller than
1/4" diameter shall be used
GA Tech Safety and Health Consultation Program
Guardrails
GA Tech Safety and Health Consultation Program
Wire Rope
GA Tech Safety and Health Consultation Program
Flagged Wire Rope
GA Tech Safety and Health Consultation Program
2 x 4 Guardrails
GA Tech Safety and Health Consultation Program
Fall Protection Systems:
criteria and practices...
(b) Safety net systems
Shall be installed as close as practicable , but in no case
more than 30' (9. 1 m) below the working surface
Shall be subjected to impact force tests or certified
Without any defects
Shall be inspected weekly and after any occurrence
(impact)
Debris that have fallen into the net must be removed
before starting work
Maximum size of each mesh opening shall not be longer
than 6” and each opening will not exceed 36” square
All border rope must have a minimum breaking strength
of 5000 pounds GA Tech Safety and Health Consultation Program
Fall Protection Systems:
criteria and practices...
(c) Personal fall arrest systems
Effective January 1, 1998, body belts are authorized
to be used only for positioning
Dee-rings and snaphooks shall have a minimum tensile
strength of 5,000 pounds
Snaphooks shall be of the locking types
Horizontal lifelines shall be installed by a qualified
person and maintain a safety factor of at least 2
GA Tech Safety and Health Consultation Program
GA Tech Safety and Health Consultation Program
Fall protection
Chain for
positioning
Body belts only for positioning
GA Tech Safety and Health Consultation Program
Fall Protection Systems:
criteria and practices...
(c) Cont..
Lanyards and vertical lifelines shall have a minimum
breaking strength of 5,000 pounds
A body harness shall withstand a force of 1,800 pounds
Be mindful of the correct attachment point to the
wearer’s body, plans for prompt rescue of the employee,
and inspections of equipment prior to use
GA Tech Safety and Health Consultation Program
Fall Protection Systems:
criteria and practices...
(d) Positioning device systems
Employee can not free fall more than 2' (0.61 m)
Shall be inspected prior to each use
Body belts and harnesses shall be used only for
employee protection
(e) Warning lines
Shall be erected around all sides of the roof work area
GA Tech Safety and Health Consultation Program
Fall Protection Systems:
criteria and practices...
(e) Cont.
Mechanical equipment shall be placed not less than 6'
(1.8 m) from the roof edge
Access points shall be blocked when there is no work
Warning lines shall be flagged with high-visibility
materials
The lowest point of the warning line is not less than 34"
(0.9 m) and the highest point at not more than 39" (1 m)
GA Tech Safety and Health Consultation Program
Fall Protection Systems:
criteria and practices...
(f) Controlled access zones
Used in areas where leading edges change constantly
In areas with overhand bricklaying work at edges
When erecting precast concrete members
Access permitted only to trained and qualified
employees
Written information (signs) at points of access
GA Tech Safety and Health Consultation Program
Leading edges
GA Tech Safety and Health Consultation Program
Fall Protection Systems:
criteria and practices...
• (g) Safety monitoring systems
Competent person as
Only employees engaged in
monitor
roofing work allowed
At same visual level of
Employees shall follow the
that of employees
monitor’s instructions
Close enough to
Monitor shall not have other
communicate orally
responsibilities or functions
Mechanical equipment
shall not be stored in the
monitoring area
GA Tech Safety and Health Consultation Program
Monitor
GA Tech Safety and Health Consultation Program
Warning line
GA Tech Safety and Health Consultation Program