3. 太陽能工程-第三章

Download Report

Transcript 3. 太陽能工程-第三章

National Formosa University
第三章 太陽電池測定法
measurement for solar cell
Institute of Electro-Optical and Material Science
1
National Formosa University
3-1 Circuit of series and parallel
resistance measurement method
3-1-1 Series resistance
Institute of Electro-Optical and Material Science
2
National Formosa
University
I
I = I [exp(eV/k T)  1]
o
B
mA
V
Shockley equation
Reverse I-V characteristics of a
pn junction (the positive and
negative current axes have
different scales)
nA
Space charge layer
generation.
© 1999 S.O. Kasap,Optoelectronics(P rentice Hall)
Institute of Electro-Optical and Material Science
3
National Formosa University
The solar cell equivalent circuit of
series and parallel resistors
Institute of Electro-Optical and Material Science
4
National Formosa University
Series resistance
The series resistance includes the
Resistance of the surface and inside
the electrode, the electrode
semiconductor interface of omic- contact
resistance, the carrier flow
through the resistance and the overall
resistance of the surface layer,calculated
as the general use of the analytical
method of Handy and Milnes.
Series resistance, the easiest
determination to calculate the
characteristics of a straight line along the
direction of part.
Institute of Electro-Optical and Material Science
5
National Formosa University
3-1 Circuit of series and parallel
resistance measurement method
3-1-2 Parallel resistance
Institute of Electro-Optical and Material Science
6
National Formosa University
shunt resistance
Parallel resistance in the joint of defects for a long time,
leakage current, or the formation of incomplete bonding,
there will beproblems occur. Parallel resistance is
bigger than 1kΩ, so theeffects can be ignored.
Detection of faint light in the use of solar cells because
of thephotocurrent is very small, the parallel resistance
is a big influence.
Parallel resistance of the determination, the general
characteristics of the linear portion of the easiest of
the inverse direction to calculate.
Institute of Electro-Optical and Material Science
7
National Formosa University
The solar cell equivalent circuit of series
and parallel resistors
Institute of Electro-Optical and Material Science
8
National Formosa University
3-2 光源
3-2-1 基準太陽光
Institute of Electro-Optical and Material Science
9
National Formosa University
基準太陽光
由於地上之太陽光的變動,故必須指定空氣質量值
(Air Mas),即AM值及大氣常數亦稱為基準太陽光,
以決定測定時照度。
現在日本品質保證機構及美國DDE所採用之基準太
陽光,是以美國IEC所提案,傾斜面全天日射之基準
分光放射分佈為基準,且考慮散射光成分之TC-82標
準。
Institute of Electro-Optical and Material Science
10
National Formosa University
基準分光散亂分佈(TC-82)
基準分光散亂分佈(TC-82)(取材自國際電子技術委員會) ,如
圖溫度為25℃
11
Institute of Electro-Optical and Material Science
National Formosa University
3-2 光源
3-2-2 測定用光源
Institute of Electro-Optical and Material Science
12
National Formosa University
測定用光源
測定用光源-人工光源,最理想者為基準太陽光
與分光放射照度相等,且全放射照度可變者最佳
。
現實上那種光源裝置太困難。現在檢討中之種類
有Xeon Short Arc Lamp,Long Arc之pulse Xe光
,W-鹵素燈(附有紅外線補正)者。
不管那一個光源,皆含有光學系統及光譜補正濾
波器,使其與地上太陽光之基準光譜可以比較。
Institute of Electro-Optical and Material Science
13
National Formosa University
測定用光源
定常光型(連續光型)人工光源
使用Xe燈以外光源定光型人工光源
Pulse型人工光源
複合型人工光源
Institute of Electro-Optical and Material Science
14
National Formosa University
定常光型(連續光型)人工光源
通常所使用的定常光型人工光源,係使用Xe短弧燈泡作
為光源,其特徵為(1)色溫度6000K,靠近太陽之溫度
(5762K);(2)亮度高,使用適當之光學系統可以得到好的
光束,反之,由於在近紅外光部存有Xe特有之強光線,
為了抑制它,必須使用補正過濾器。
Xe短弧之放射光含有連續光譜及亮線光譜,增加燈泡電
流時,使前者之強度比後者之強度增加,使用色溫度與
太陽溫度相似之Xe弧燈,是為要得與基準太陽光靠近之
分光放射分佈,除了要使用能抑制近紅外部之亮線過濾
器外,需要與大氣之透過特性等價過濾器。
因大氣而散射之紫外線及存在強光輝線之近紅外線
(800~1000nm)使用2枚層膜過濾器將其抑制後,即可得
AM-1,AM-1.5及AM-2之人工光源。
Institute of Electro-Optical and Material Science
15
National Formosa University
500W Xe燈泡分光放射度的燈泡電流依存性
圖為500W之Xe燈泡
以25A(500W),
15A(300W)點登之光
譜分佈的比較圖
Institute of Electro-Optical and Material Science
16
National Formosa University
AM-1.5人工光源分光放射特性
圖為使用AM1.5人工光源
之分光放射特
性
Institute of Electro-Optical and Material Science
17
National Formosa University
使用Xe燈以外光源定光型人工光源
Xe燈泡以外之光源,首先想到的是鹵素鎢絲燈泡,這是將Br或I等注入到鎢絲燈泡
內以求得高溫之方法。然而溫度只有
3000~3400K,比太陽之溫度要低,光譜分
佈偏向長波長。
Institute of Electro-Optical and Material Science
18
National Formosa University
鹵素燈泡分光放射照度
如圖不太適合當人工光源。
Institute of Electro-Optical and Material Science
19
National Formosa University
ELH燈泡人工光源分光放射特性
將鹵素燈掛上適當
的Dichroic鏡之
ELH燈泡,其分光
放射特性,如圖使
得它可以做為太陽
電池之測定。
Institute of Electro-Optical and Material Science
20
National Formosa University
鹵化金屬(MX)燈泡之分光放射特性
金屬鹵化合物燈泡
光源,是將MX封
入放電燈內,以封
入金屬之發光來調
整光光譜,如圖兩
者相當一致,即使
沒有補正過濾器,
也可當做人工光源
來使用。
Institute of Electro-Optical and Material Science
21
National Formosa University
Pulse型人工光源
光源使用Xe閃光燈泡,瞬時可注入大電力至燈泡
,利用高亮度發散光,使大面積之照射成為可能
,做為太陽電池模組之測定,在某時間內之光量
為一定,但是電流電壓特性之測定時間卻很短,
因此需要使用能高速處理數據用的電腦系統
Pulse型人工電源放射照度之調節有(1)改變照
射距離法,(2)改變燈泡電流之兩種方法。使用
後者時光譜分佈也會變化,連續光譜將比亮線光
譜大,故不需AM過濾器。(但因色溫高達
7000~9000K,故需要紫外線的補正過濾器)。但
由於燈泡負荷過大,壽命較短。
Institute of Electro-Optical and Material Science
22
National Formosa University
Xe閃光燈泡人工光源分光放射特性
如圖顯示了pulse型
人工電源之分光放
射特性。
Institute of Electro-Optical and Material Science
23
National Formosa University
複合型人工光源
使用Xe燈泡之人工光源在近
紅外線處有獨特的亮線,為
了抑制此輝線,故開發出與
鹵素燈組合之二光源系統。
如左圖顯示此二光源系統之
分光放射特性。此等人工光
源用來評估在紅外線部分,
具有感度特性之太陽電池較
有效。
Institute of Electro-Optical and Material Science
24
National Formosa University
3-3 出力特性換算及補正
Institute of Electro-Optical and Material Science
25
National Formosa University
出力特性換算及補正
• 絕對值較正法
• 參考電池法
Institute of Electro-Optical and Material Science
26
National Formosa University
3-3 出力特性換算及補正
3-3-1 絕對值較正法
Institute of Electro-Optical and Material Science
27
National Formosa University
絕對值校正法
太陽電池所產生的光短路電流
2
I SC1   I S ( )  F1 ( )d
1
IS(λ)為太陽電池之絕對分光感度
F1(λ)為入射光之分子數的光譜
λ1為太陽電池之最短感度波長
λ2為太陽電池之最長感度波長
Institute of Electro-Optical and Material Science
28
National Formosa University
絕對值較正法
太陽電池之絕對分光感度IS(λ)為各波長上,
入射光子數與外部可取出之電荷數之比。
當一個光子入射,且有一個電荷當做電流被
取出時,其值為1。另外F1(λ)表示入射光之各
波長的光子數。
IS(λ)與F1(λ)之積為入射光在各波長相對應之
電流值。
此積分用波長乘積時,即得到入射光所發生
之短路電流。
Institute of Electro-Optical and Material Science
29
National Formosa University
絕對值較正法
針對實際的測定法,IS(λ)為使用附有偏差光之
定光子分光器來測定。所謂偏差光即為分光感度
測定時,附加至單色光之白光,為要求得實際使
用狀態下之分光感度時必要的東西。
因此偏差光必須與測定對象之入射光同種類及強
度。
Institute of Electro-Optical and Material Science
30
National Formosa University
絕對值較正法
單色光之光密度為一定值A之定光子分光器
,所測定的太陽電池之電流為ICP(λ)時,則
IS(λ)值由下式求得,S為太陽電池之面積
I CP ( )
I S ( ) 
SA
Institute of Electro-Optical and Material Science
31
National Formosa University
絕對值較正法
絕對值校正法之重點,在利用定光子分光器測分光感度正
確之絕對值。定光子分光器產生的單色光之光子數(能量
密度),直空熱電偶等高精度功計來測定,但因測定對全
體的測定精度有影響,故需校正絕對分光放射強度。
此外入射光的光子數光譜F1(λ)之值,係將測定對象光之
能量密度光譜,換算成光子密度之值。
當IS(λ).F1(λ)求得時,依前式可求得規定的入射光之太陽
電池的短路電流ISC1,此ISC1之值與實際測定到之短路電流
ISC2之比CSC,即為補正後校正係數
2
I ( )  F ( )d

C 

I
I ( )  F ( )d

Institute of Electro-Optical and Material Science
I SC1
SC
SC 2
1
2
1
S
1
S
2
32
National Formosa University
3-3 出力特性換算及補正
3-3-2 參考電池法
Institute of Electro-Optical and Material Science
33
National Formosa University
參考電池法
選擇幾乎沒有經時變化之特性者,定期校
正
參考電池必須與待測太陽電池之分光感度
特性較一致者
Institute of Electro-Optical and Material Science
34
National Formosa University
3-4 照度及溫度之依存性
Institute of Electro-Optical and Material Science
35
National Formosa University
照度及溫度之依存性
太陽電池隨測定時之溫度及照度,其特性
會改變,當測定條件改變時,即需測其特
性,故其效率差。
Institute of Electro-Optical and Material Science
36
National Formosa University
照度及溫度之依存性
基準狀態下之電壓、電流、放射照度及被測定太
陽電池之電池溫度,各以V2、I2、E2、T2表示,
而任意狀態下被測定之相對值及短路電流,以V1
、I1、E1、T1及ISC表示時,用下列進行補正。
 E2 
I 2  I1  I SC 
 1   (T2  T1 )
 E1 
V2  V1   T2  T1   RS I 2  I1   KI 2 T2  T1 
Institute of Electro-Optical and Material Science
37
National Formosa University
照度及溫度之依存性
四個補正係數代表太陽電池特性之係數
,其測定及計算法在以下說明
1. ISC及VOC之溫度係數:α,β
2. 串聯電阻曲線補正因子:RS
3. 曲線補正因子:K
Institute of Electro-Optical and Material Science
38
National Formosa University
ISC及VOC之溫度係數:α,β
以放射照度100±1mW/cm2,約10℃間隔,至少5點在
10~70℃範圍內之變化溫度,測定出力特性。必須注意太
陽電池之溫度要保持安定,各溫度下所得到之ISC及VOC對
溫度作圖,以最小二乘法做直線校正。
以上之手法所得直線之斜,以出力電流之溫度係數α(A/℃)
及出力電壓之溫度係數βc(V/℃)表示。
模組出力電流及出力電壓之溫度係數α及β值,各以下式計
算,其中ηp為模組並聯之電池數而ηs為串聯電池數。
  P C
  S  C
Institute of Electro-Optical and Material Science
39
National Formosa University
串聯電阻:RS
圖中所示,以二不同放射照度在
室溫測定其I-V特性曲線。室溫
之變化控制在2℃以內。選高放
射照度下I-V特性曲線上,比Vpm
稍高之電壓P點,設此電池值與
ISC1之差為△I,則低放射照度下
之I-V特性曲線上之電流等於ISC2△I之點Q可以求得。
Institute of Electro-Optical and Material Science
40
National Formosa University
曲線補正因子:K
在太陽電池使用之溫度範圍內,並選擇30℃以
上之溫度幅寬3點,T3、T4及T5。各溫度下之IV特性,以放射照度為1點來測定K之推定值。
Institute of Electro-Optical and Material Science
41
National Formosa University
3-5 太陽電池單體特性實測法
solar cell
3-5-1 太陽單體電池測定
Institute of Electro-Optical and Material Science
42
National Formosa University
太陽單體電池測定
參考電池之校正
人工光源之光量調整
太陽電池測定
Institute of Electro-Optical and Material Science
43
National Formosa University
參考電池之校正
太陽電池特性之測定在之測定在之前說明過,
從待測之太陽電池群中選出代表的太陽電池,
以此太陽電池做為參考電池以測定其他的太陽
電池之特性。此地所謂的太陽電池群指具有同
樣分光感度特性而言,考慮電池法中正確評估
參考電池之短路電流ISC,極其重要。其正期望
由權威機構如日本晶保機構進行
Institute of Electro-Optical and Material Science
44
National Formosa University
人工光源之光量調整
校正過之參考電池在人工光源下測定,
將其短路電流利用人工光源之光量調整
,調整到短路電流之校正值。
Institute of Electro-Optical and Material Science
45
National Formosa University
太陽電池測定
調整光量後,測定待測之太陽電池。此
時樣品位置必須兵參考電池同位置,此
為避免人工光源在光強度內面之誤差值
Institute of Electro-Optical and Material Science
46
National Formosa University
3-5-2 大面積模組之測定
Institute of Electro-Optical and Material Science
47
National Formosa University
大面積模組之測定
進行模組之測定,除面積較大外,其餘與單位電池之基本
性質相同。人工光源之選定,要能確保照射至所需面積,
確保均一性並不容易,需要更高精度之人工光源。
通常模組包含數個單體電池之串聯,因為各單體電池之電
流值為全體效率之控制因子,故對之均一性有很大影響。
在測定時若模組之方向不同,則測定結果亦不同。
模組極端大之場合,可能人工光源無法罩住所有之面積,
此時只有利用屋外自然光。
Institute of Electro-Optical and Material Science
48
National Formosa University
3-5-3 太陽電池特性測定重點
Institute of Electro-Optical and Material Science
49
National Formosa University
太陽電池特性測定重點
國際電子規格準化委員會IEC之規定為25℃,若在不同溫
度下測定時,要將其換算為25℃之值。
針對非晶矽長時間光照射之光劣化實驗上,使用有防止溫
度上升之冷凍機的人工光源,當光照射時,不斷進入保溫
用冷氣。
為了增加太陽電池特性之測定精度,可以將參考電池與待
測太陽電池同時測定,補正測定時燈光強度之變動或位移,
將數次之測定值再加以平均。
使用人工光源時,必須牢記人工光源之光譜分佈,起因之
曲線因子及開路電壓之變化。
Institute of Electro-Optical and Material Science
50