Lynx Series Web Training
Download
Report
Transcript Lynx Series Web Training
Lynx Series
Lynx Plus
LynxR-2
LynxR-EN
LynxR-i
LynxR-iSIA
Honeywell.com
Agenda
•Panel Features
•Connecting an AlarmNet Communicator
•Programming Locations
•*56 Enhanced Zone Programming
•*80 Device Programming
•*81 Zone List Programming
2
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Features
•AlarmNet Communicator Compatible *
•IP/GSM Downloading Compatible *
•Wireless Siren Compatible – 5800WAVE
•Wireless Keypad Compatible – 5828V Fixed English
•Built in Speakerphone
•Built in Remote Phone Control
•Built-in Two-way voice system - AAV
•Numeric Pager Reporting
•Follow-Me Alarm Reporting (voice message)
* Options of the Lynx Plus, LynxR-2 and LynxR-i
Central Station reporting required for Pager and Follow-Me Alarm
reports except for Open and Close reports
3
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Plus Features
•Supports two-way voice over GSM radio
–with the GSMVLP radio module
•Full 16-button keypad with easy-to-read LCD display and status LEDs
–2” x 16” Custom Alpha backlit display
•Hinged cover for simpler installations
4
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Features
•Rechargeable batteries
–6 x 1.2V Nickel Metal-Hydride pack
•provides 24 hours of standby
•Enhanced Enroll Mode
–Can enroll Confirm serial number
–View serial number
–Change loop number w/o deleting
•RF jam detection
5
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Features
•1 Hardwire zone – Not present on LynxR-2 or LynxR-i
•24 Wireless zones
•16 Button zones
–5804, 5804BD, BDV, & 5802MN
•8 user codes
–1 installer
–1 master
–1 duress
–5 standard
•84 Event log – Viewable from Compass Only
•On-board UL 85db siren
6
Lynx Series Web
Honeywell Proprietary
Lynx Series
AlarmNet Connections
Honeywell.com
AlarmNet Communicator
GSMVLP
Status LEDs
Signal Strength
LED
Must be solid.
Registration and
Test Switch
8
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Lynx Plus AlarmNet Communicator Mounting
Installing the GSMVLP Module
9
Lynx Series Web
Honeywell Proprietary
Honeywell.com
AlarmNet Communicator Connection
Wiring Connections and Routing
10
Lynx Series Web
Honeywell Proprietary
Honeywell.com
AlarmNet Communicator
GSML
Status LEDs
Signal Strength
LED
Must be solid.
Registration and
Test Switch
11
Lynx Series Web
Honeywell Proprietary
Honeywell.com
AlarmNet Communicator
GSML
12
Lynx Series Web
Honeywell Proprietary
Honeywell.com
AlarmNet Communicator Connections
LynxR-2/R-i & 7847i-L Configuration B
13
Lynx Series Web
Honeywell Proprietary
Honeywell.com
AlarmNet Communicator Connections
LynxR-2/R-i & 7845GSM / 7845i-GSM
Do Not Connect the
7845GSM internal
battery!
NOTE: DC Power is supplied from Lynx panel.
14
Lynx Series Web
Honeywell Proprietary
Honeywell.com
AlarmNet Communicator Connections
LynxR-2/R-i & 7847i
15
Lynx Series Web
Honeywell Proprietary
Honeywell.com
AlarmNet Communicator Connections
LynxR-EN & AlarmNet Device
2K Ohm Pull up resistor.
Program your AlarmNet Device
in V- (neg) Zone Mode.
16
Lynx Series Web
Honeywell Proprietary
Honeywell.com
AlarmNet Communicator Connections - LynxDM-GSM
17
Lynx Series Web
Honeywell Proprietary
Honeywell.com
AlarmNet Communicator Connections
LynxDM-GSM
18
Lynx Series Web
Honeywell Proprietary
Lynx Series
Programming
Honeywell.com
Programming Locations
* 20 Installer Code
[4112]
Example 1
To change the Inst. Code you would enter *20 then the new code:
For example: Change Installer code to 4321
* 2 0 4 3 2 1 (after entry of last digit the keypad will beep 3 times to
confirm the entry and automatically proceed to location *21)
20
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Programming Locations
*20 Installer Code
[4112]
Example 1
To view what is in location *20 you would enter:
# 2 0 the panel will then display the location contents one digit at a
time (in hexadecimal format)
For example: # 2 0 then the panel would display:
04 (beep) 03 (beep) 02 (beep) 01 (beep, beep, beep)
The installer code is 4321.
A triple beep is heard after the last digit of the field is displayed.
21
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Programming Locations
*21 Quick Arm Enable
[1]
*22 Keypad Backlight Time Out
[0] 0 = always on
1 = off after 10secs
*24 RF House ID Code
0 = no; 1=yes
[00] 00 = disable
01-31 = house ID
22
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Programming Locations
*25 Powerline Carrier device
House Code
[0]
*26 Chime by Zone
[0] 0 = no; 1 = yes
Program zones to chime on zone list 3
*31 Single Alarm Sounding/Zone
*31 Single Alarm Sounding/Zone SIA
[0] 0 = no limit
1 = yes, once per arming
[0]
0 = Same as Shutdown in field *92
1 = yes, once per arming period
*33 Alarm Bell Timeout
[1] 0 = none; 1 = 4min
2 = 8min; 3 = 12min; 4 = 16min
23
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Programming Locations
Daylight Saving Time
*29 Daylight Saving Time
Start/End Month
[3,11]
This is March and November.
*30 Daylight Saving Time
Start/End Weekend
[2,1]
This is the 2nd Sunday in March and the 1st Sunday in November.
24
Lynx Series Web
Honeywell Proprietary
Honeywell.com
SIA Entry Exit Times
*34 Exit Delay
[6,0]
SIA: Must be set to a minimum 45 sec.
00-99 = exit delay time (in sec)
97 = 120 sec delay
*35 Entry Delay 1 (zone type 01)
[3,0]
SIA: The entry delay must be set to a minimum of 30
seconds. The sum of entry delay 1 field *35 and the
burglary abort window entered in *50 should not exceed
1 minute.
30-96 = entry delay time (in sec.)
97 = 120 sec; 98 = 180 sec;
99 = 240 sec
25
Lynx Series Web
Honeywell Proprietary
Honeywell.com
SIA Entry Exit Times
*36 Entry Delay 2 (zone type 02)
SIA: The entry delay must be set to a minimum of 30
seconds. The sum of entry delay 2 field *36 and the
burglary abort window entered in *50 should not exceed
1 minute.
[3,0]
30-96 = entry delay time (in sec.)
97 = 120 sec; 98 = 180 sec;
99 = 240 sec
*50 15 sec Dialer Delay (Burg)
[0] 0 = no; 1 = yes
*50 Burglary Abort Window SIA
[2] 1 = 15 sec; 2 = 30 sec;
3 = 45 sec
26
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Phone Options
*38 Confirmation of Arming Ding
[0]
0 = no; 1 = yes (when armed by self-contained keypad or RF)
2 = yes (when armed by RF only)
*40 PABX Access Code
SIA PABX/Call Waiting Disable
Up to 6 digits
*41 Primary Phone No.
...
Up to 20 digits
27
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Phone Options
*42 Secondary Phone No.
Numeric Pager or
Follow-Me Alarm
…
Up to 24 digits
*43 Primary Account Number
4 or 10 Digits
[ FFFF ]
4 or 10 Digits
[ FFFF ]
*44 Second Account Number
The Account Number will be 10 digits only if 10 Digit Contact ID Format is
selected in *48 Report Format.
28
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Phone Options
*46 Follow-Me Reminder
Phone Number
…
Up to 24 digits
[5]
*47 Phone System Select
Central Station
Dialing Mode
Pulse
Tone
Pulse
Tone
No WATS
0 = No
Speaker
Phone
1 = No Speaker
Phone
4 = With Speaker
Phone
5 = With Speaker
Phone
WATS
2 = No
Speaker
Phone
3 = No Speaker
Phone
6 = With Speaker
Phone
7 = With Speaker
Phone
29
Lynx Series Web
Honeywell Proprietary
Honeywell.com
SIA Only
Phone System Select
*47 Phone System Select
SIA Only
[5]
30
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Format
*48 Report Format for PRIM/SEC.
[ 7,7 ]
Primary
0 = 3+1, 4+1 Ademco L/S Standard
1 = 3+1 4+1 Radionics Standard
2 = 4+2 Ademco L/S Standard
3 = 4+2 Radionics Standard
Secondary
6 or undefined = 4+2 Ademco Express
7 = Ademco Contact ID reporting
8 = 3+1, 4+1 Ademco L/S Expanded
9 = 3+1, 4+1 Radionics Expanded
5 = Ademco 10 Digit Contact ID Format
NOTE: Option 5 or 7 (Ademco Contact ID) must be selected for AAV.
ADEMCO Contact ID Example:
1234 E 131 00 C005
This is a new Perimeter Alarm on Zone 5,
Account #, the Event (E = new, R = restore )
Event Code, Zone #
31
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Reporting Options
Dialer Programming
*49 Split/Dual Reporting
TO PRIMARY PHONE No.
1 = Alarms, Restore, Cancel
2 = All except Open/Close , Test
3 = Alarms, Restore, Cancel
4 = All except Open/Close, Test
5 = All
TO PRIMARY PHONE No.
6 = All except Open/Close
7 = All reports
8 = All reports
9 = All except Open/Close
TO PRIMARY PHONE No.
10 = All except Open/Close
11 = All reports
12 = All reports
13 = All except Open/Close
[0] 0 = Disable (Backup report only)
TO SECONDARY PHONE No.
Others
Open/Close, Test
All
All
All
TO PAGING No. (Secondary)
Alarms, Open/Close‡, Troubles
Alarms, Trouble
Alarms, Open/Close‡, Troubles
Open/Close‡
TO Follow-Me Alarm No. (Secondary)
Alarms, Open/Close‡, Troubles
Alarms, Trouble
Alarms, Open/Close‡, Troubles
Open/Close‡
‡ Will report users 0, 5-8 or wireless arm/disarm button
Zones 26-33; all other zones and users do not report
32
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Periodic Test
*51 Periodic Test Report
[0] 0 = none; 1 = 24 hrs;
2 = weekly; 3 = 30 days
*52 First Test Report Offset
[2] 0 = 24 hr; 1 = 6 hrs;
2 = 12 hrs; 3 = 18 hrs
*64 Test Report Code
[1,0]
*76 Test Restore Report Code SIA
[0,0]
Sent when test mode is exited.
33
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Programming Locations
*59 Exit Error Report Code
[1]
*60 Trouble Report Code
[1,0]
*65 Open Report Code
[0]
*66 Arm Away/Stay Rpt Code
[0,0]
AWAY
STAY
34
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Programming Locations
*55 Enable LRR/IP
Communications Device
[0]
*77 Dynamic Signaling Delay/
Dynamic Signaling Priority
[0, 0]
1st Entry
(delay before switching Central
Station reporting path)
0 = Redundant reporting
8 = 120 seconds
1 = 15 seconds
9 = 135 seconds
2 = 30 seconds
#10 = 150 seconds
3 = 45 seconds
#11 = 165 seconds
4 = 60 seconds
#12 = 180 seconds
5 = 75 seconds
#13 = 195 seconds
6 = 90 seconds
#14 = 210 seconds
7 = 105 seconds
#15 = 225 seconds
0 = Disable;
1 = Enable
2nd Entry
0 = Primary Dialer First
1 = LRR/IP First
2 = LRR/IP Reporting Only
35
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Programming Locations
*87 Aux Function 1-button paging or Macro
– Send 999-9999 to a pager or can be a Macro
*88 Pager Characters
– Enter up to 16 digits as needed for customizing pager messages
or pager requirements (PIN’s etc.)
*90 Event Logging
[3]
0 = None;
1 = Alarm/Alarm Restore
2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore;
8 = Open/Close
To select all, enter #15
36
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Programming Locations
*91 Alarm Audio Verification/Remote Phone Control
[2]
0 = None; 1 = AVM & remote phone control
2 = remote phone control only
4 = AVM only
*92 Number Of Reports in Armed Period
[0]
0 = 10 Alarm/Alarm Restore Reports; 1 = Unlimited
*92 Swinger Shutdown SIA
[1]
1 = shutdown after one alarm
2 = shutdown after two alarms
37
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Programming Locations
*94 Download Phone No.
…
Up to 20 Digits
*95 Ring Detect Count for Downloading
[0]
0 = Disable Station Initiated Download;
1-14 = Number of rings;
15 = Answering Machine Defeat
38
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Programming Locations
*96 Initializes Download ID, Subscriber Account No.
For Initial Download; No entry required
*97 Select 1 of 4 Default Option Setups. Enter 1-4 to
select from default tables 1-4. Enter 0 to abort.
*98 Exits Programming mode and prevents re-entry by
Installer Code +8+0+0
*99 Exits Programming mode and allows re-entry by
Installer Code +8+0+0
39
Lynx Series Web
Honeywell Proprietary
Lynx Series
*56 Enhanced Zone Programming
Honeywell.com
*56 Enhanced Zone Programming
A 02
A 02
ZONE NUMBER
b 01
b 01 ENTR/EXIT#1
ZONE TYPE
Zone Number
Enter the 2-digit zone number to be programmed
[*] = Continue
00 = exit zone programming mode
Zone Type
Enter the 2-digit zone type.
[*] = Continue
00 =
Not Used
08 =
24 Hr. Aux
01 =
Entry/Exit #1
09 =
Fire without verify
02 =
Entry/Exit #2
10 =
Interior w/Delay
03 =
Perimeter
20 =
Arm-Stay
04 =
Interior Follower
21 =
Arm-Away
05 =
Trouble Day/Alarm Night
22 =
Disarm
06 =
24Hr. Silent
23 =
No Alarm Response
07 =
24Hr. Audible
24 =
Silent Burglary
41
Lynx Series Web
Honeywell Proprietary
Honeywell.com
*56 Enhanced Zone Programming
C 10
C10
REPORT CODE
d 3
d 3 RF SUPERVSD
INPUT TYPE
Report Code
Enter the report code
Input Type
Enter the input type
3 = Supervised RF (RF) 4 = Unsupervised RF (UR)
5 = Button type (BR)
[*] = Continue
E 1
E2
LOOP#/AUTO LEARN
Loop Number
It takes 4 transmissions to learn in the Serial and Loop
Numbers.
1st Fault and Restore – a single beep will sound.
2nd Fault and Restore – a double beep will sound.
-If a voice descriptor is already programmed for the
zone, it will also be announced.
42
Lynx Series Web
Honeywell Proprietary
Honeywell.com
*56 Enhanced Zone Programming
E 2L
E2L LEARNED
LOOP#/AUTO LEARN
An “L” will appear after the loop number
if the loop number was learned in.
1A L
1AL A000-1234
ENROLL MODE
Enroll Mode
0 = Skip to the VOICE DESCRIPTOR prompt (1C)
1 = Enroll now and proceed to SERIAL NUMBER prompt (1b) (If “ L” is not displayed)
2 = Copy the last serial number from the local memory buffer (If “L” is not displayed)
3 = View existing serial number. (Only if “L” is displayed)
9 = Delete existing serial number. (Only if “L” is displayed)
[*] = Advance to the VOICE DESCRIPTOR prompt (1C)
43
Lynx Series Web
Honeywell Proprietary
Honeywell.com
*56 Enhanced Zone Programming
1A
1A
ENROLL MODE
Manual Serial Number Entry
Press [1] at the 1A prompt to manually enter the
transmitters serial number
1b
1b
SERIAL NUMBER
Manually enter the transmitter’s 7-digit serial
number. When all 7 digits are entered, press the [*] key.
1A L
1AL A000-1234
ENROLL MODE
After entry is completed, you may trip the transmitter to
confirm the serial number entry is correct, or press [*] to
skip.
44
Lynx Series Web
Honeywell Proprietary
Honeywell.com
*56 Enhanced Zone Programming
1C
1C
ZONE DESCRIPTOR
Voice Descriptor
-(Can also be entered separately in *84)
0 = skip to next zone
1 = Enter descriptor mode
1d 47
1d47
Front
FRONT
Descriptor 1
Enter [#] + 2 digit vocabulary index number
6 = accept word and advance to descriptor 2
8 = accept word and advance to next zone
45
Lynx Series Web
Honeywell Proprietary
Honeywell.com
*56 Enhanced Zone Programming
1E 69
1E69
Sliding
SLIDING
1F 12
1F04
Door
DOOR
Descriptor 2
Enter [#] + 2 digit vocabulary index number
6 = accept word and advance to descriptor 3
8 = accept word and advance to next zone
Descriptor 3
Enter [#] + 2 digit vocabulary index number
8 = accept word and advance to next zone
(A prompt) A 03
A03
ZONE NUMBER
00 = exit zone programming mode
46
Lynx Series Web
Honeywell Proprietary
Lynx Series
*80 Device Programming
Honeywell.com
*80 Device Programming
80
80
DEVICE PROG MENU
A01
A01
DEVICE NUMBER
b 2
b02
DEVICE ACTION
Device Programming
0 = Exit mode
1 = Enter mode
Device Number
Enter the 2-digit device number
01-08 = X-10
09-16 = Multi-Mode Total Connect
[*] = Continue
00 = Exit Device Programming mode
Device Action
Enter the 1-digit action
0 = No response
1 = Close for 2 seconds
2 = Close and stay closed
3 = Pulse on and off
[*] = Continue
48
Lynx Series Web
Honeywell Proprietary
Honeywell.com
*80 Device Programming
C 2
C02
START EVENT TYPE
d 1
d01
START ZONE LIST
Start Event Type
Enter the 1 – digit start event type
0 = Not used
3 = Trouble
1 = Alarm
[*] = Continue
2 = Fault
Start Zone List
Enter the 1– digit zone list number, 1-3, or 0
if not used;
[*] = Continue
49
Lynx Series Web
Honeywell Proprietary
Honeywell.com
*80 Device Programming
E 00
E00
START ZONE TYPE
F 0
F00
STOP ZONE LIST
1A22
1A22
STOP ZONE TYPE
Start Zone Type
Enter the 2-digit start zone type
[*] = Continue
Stop Zone List
Enter the 1-digit zone list number, 1-3, or 0
if not used
[*] = Continue
Stop Zone Type
Enter the 2-digit stop zone type
[*] = Return to Device Number prompt (A)
A02
A02
DEVICE NUMBER
50
Lynx Series Web
Honeywell Proprietary
Lynx Series
*81 Zone Lists
Honeywell.com
*81 Zone List Programming
81
81
ZONE LISTS MENU
A01
A01
ZONE LIST NUMBER
b28
b28
ZN ENTRY TO LIST
Zone List Programming
0 = Exit mode
1 = Enter mode
Zone List Number
Enter the 2-digit zone list number (01-03)
[*] = Continue;
00 = Exit mode
Zone Entry To List
Enter the 2-digit zone number
[*] = Accept zone number and enter the next zone number
00 = Accept zone number and continue to next prompt
52
Lynx Series Web
Honeywell Proprietary
Honeywell.com
*81 Zone List Programming
C
C
DEL WHOLE ZN LST
d
d
DEL 1 ZN FRM LST
E
E00
DELETE ZONES
Delete Entire Zone List?
0 = Don’t delete; continue to next prompt
1 = Delete the current zone list
Delete Specific Zones from List?
0 = Don’t delete; continue to next zone list number
1 = Continue to delete zones prompt
Delete Zones
Enter the 2-digit zone number to be deleted
[*] = Delete zone
00 = Return to next zone list number
53
Lynx Series Web
Honeywell Proprietary
Honeywell.com
Review Quiz
•How do we view what is in a standard programming location?
•How do we enter data in standard programming location?
•What programming mode do we use to program in wireless
transmitters?
•Does the LynxR-EN have an event log?
•Will the system report in Contact ID with an AlarmNet Communicator?
54
Lynx Series Web
Honeywell Proprietary
http://www.security.honeywell.com/hsc/
and click on MyWebTech
User name: honeywell
Password: support99
Honeywell Security support e-mail: [email protected]