Transcript berker b.iq

BERKER B.IQ

DESIGN & VERSIONS CONSTRUCTION & DIMENSIONS STRUCTURE OF THE DISPLAY PARAMETER TECHNICAL DATA

08.2013 Ze Bekrer B.IQ

2

B.IQ

DESIGN 08.2013 Ze Bekrer B.IQ

 Frameless KNX pushbutton  4 different Materials   Glass ■ Polarwhite Black Aluminium   Plastic Stainless steel

3

B.IQ

VERISONS 08.2013 Ze Bekrer B.IQ

The Berker B.IQ is available in different verions:  1gang  2gang  3gang  4gang  3gang with RTR  4gang with RTR  5gang with RTR

4

B.IQ

DESIGN & VERSIONS

B.IQ push button 1- 4 gang Uniform installation height B.IQ push button with RTR and display 3 - 5gang 08.2013 Ze Bekrer B.IQ

5

B.IQ

DESIGN & VERSIONS

Uniform installation height 08.2013 Ze B.IQ push button 1gang Bekrer B.IQ

B.IQ push button 4gang B.IQ push button with RTR and display 3gang (also 4gang and 5gang) 6

B.IQ

1- 4GANG STANDARD

 Productname: B.IQ Pushbutton, X-gang  Order No: 7516 x0 9x

08.2013 Ze Bekrer B.IQ

7

B.IQ

1- 4GANG STANDARD

 with anti-dismantling protection  with blue operation LED and white status LEDs  for switch, push-button, dimmer and shutter functions  dimming / position value transmitter 1 byte  extension unit for light scene push button

08.2013 Ze Bekrer B.IQ

8

B.IQ

1- 4GANG KOMFORT

 Productname: B.IQ Pushbutton, X-gang comfort  Order No: 7516 x5 9x

08.2013 Ze Bekrer B.IQ

9

B.IQ

1- 4GANG KOMFORT 08.2013 Ze Bekrer B.IQ

Standard functions plus:  value transmitter for dimming, position, brightness and temperature values 1 and 2 byte  cyclic transmission can also be started via switching object  alarm telegram after disconnection from bus coupling unit 1 bit or 1 byte  single and two push-button operation parameterisable  one push-button operation for switching, pushing, shutters and dimming  activation of second user level via object

10

B.IQ

3- 5 GANG WITH RTR

 Productname: B.IQ Pushbutton, X-gang with thermostat and display  Order No: 7566 x5 9x

08.2013 Ze Bekrer B.IQ

11

B.IQ

3- 5 GANG WITH RTR 08.2013 Ze Bekrer B.IQ

 with anti-dismantling protection  With blue operation LED and white status LEDs  LC display with symbols and illumination, switchable via object  display of operating mode, controller lockout, room/outside temperature, time (clock required)  text display (ASCII-format)  with 2 additional display buttons  end customer display scope parameterisable

12

B.IQ

3- 5 GANG WITH RTR 08.2013 Ze Bekrer B.IQ

 for switch, push-button, dimmer, shutter and room thermostat functions  value transmitter for dimming, position, brightness and temperature values 1 and 2 byte  extension unit for light scene push button  single and two push-button operation parameterisable  one push-button operation for switching, pushing, shutters and dimming

13

B.IQ

3- 5 GANG WITH RTR 08.2013 Ze Bekrer B.IQ

 area dimming  shutter operation concept short-long short and long-short parameterisable  alarm telegram after disconnection from bus coupling unit 1 bit, 1 or 2 byte  with room temperature timer and 2 week timer functions  For individual single room temperature control  controller operating modes: comfort, standby, night and frost/heat protection mode

14

B.IQ

3- 5 GANG WITH RTR 08.2013 Ze Bekrer B.IQ

 for heating and/or cooling mode with/without auxiliary step  control parameter for heating / cooling unit pre-set  temperature measurement via internal and/or external sensor with mean value formation  separate window contact object  indicator objects for heating and cooling  with valve protection function  object for controller status  with flash-controller technology

15

DESIGN & VERSIONS

CONSTRUCTION & DIMENSIONS

STRUCTURE OF THE DISPLAY PARAMETER TECHNICAL DATA

08.2013 Ze Bekrer B.IQ

16

B.IQ

CONSTRUCTION & DIMENSIONS

    

Labelling field (optional) Spacer plate for the display (only required if the labelling field is used) Base plate with display Transparent protective cover for the electronics (do not remove or paint over) Design cover (only to be fitted once all installation work has been completed) 08.2013 Ze Bekrer B.IQ

17

B.IQ

CONSTRUCTION & DIMENSIONS

Base plate with display

Guide pins

Securing screws for base plate / bus coupling unit supporting ring.

User interface (PEI) 08.2013 Ze Bekrer B.IQ

18

B.IQ

CONSTRUCTION & DIMENSIONS

Display / display buttons Status LEDs 08.2013 Ze Bekrer B.IQ

Operating LED Labelling field Function buttons / rocker switches 19

B.IQ

CONSTRUCTION & DIMENSIONS

08.2013 Ze Bekrer B.IQ

20

DESIGN & VERSIONS CONSTRUCTION & DIMENSIONS

STRUCTURE OF THE DISPLAY

PARAMETER TECHNICAL DATA

08.2013 Ze Bekrer B.IQ

21

B.IQ

STRUCTURE OF THE DISPLAY Lower values (left display button) Accept a change into a sub-menu “Comfort” operating mode “Standby” operating mode “Night” operating mode 08.2013 Ze Comfort extension ( “Night” operating mode) Bekrer B.IQ

Frost / heat protection Comfort extension ( “Frost / heat protection” operating mode) Switch off room cooling in the event of condensation on the cooling unit A change made to the required value using the display buttons Programming mode Operation of the display buttons or individual rockers or operation of the device locked Timer active or control display in respective programming Reserved for future developments Heating energy is supplied or control display in the programming Cooling energy is supplied or control display in the programming Change the menu item (right display button) Raise the value (right display button) 22

DESIGN & VERSIONS CONSTRUCTION & DIMENSIONS STRUCTURE OF THE DISPLAY

PARAMETER

TECHNICAL DATA

08.2013 Ze Bekrer B.IQ

23

B.IQ

PARAMETER / ETS CONFIGUTATION

 The standard and the comfort B.IQ‘s can be configured with Parameters directly in the ETS.  The B.IQ with Display and temperature control needs a plug-in which has to be installed. This is available with the Application on www.berker.com

 The next sheets will show the parametration of a RTR B.IQ

08.2013 Ze Bekrer B.IQ

24

B.IQ

PARAMETER / ETS CONFIGUTATION 08.2013 Ze Bekrer B.IQ

25

B.IQ

PARAMETER / ETS CONFIGUTATION

 Gerneral settings

08.2013 Ze Bekrer B.IQ

26

B.IQ

PARAMETER / ETS CONFIGUTATION

 Display

08.2013 Ze Bekrer B.IQ

27

B.IQ

PARAMETER / ETS CONFIGUTATION

 Push button function

08.2013 Ze Bekrer B.IQ

28

B.IQ

PARAMETER / ETS CONFIGUTATION

 Rocker / Push button function

08.2013 Ze Bekrer B.IQ

29

B.IQ

PARAMETER / ETS CONFIGUTATION

 Status LED

08.2013 Ze Bekrer B.IQ

30

B.IQ

PARAMETER / ETS CONFIGUTATION

 Addressing by drag & drop

08.2013 Ze Bekrer B.IQ

31

B.IQ

PARAMETER / ETS CONFIGUTATION

 Addressing

08.2013 Ze Bekrer B.IQ

32

B.IQ

PARAMETER / ETS CONFIGUTATION

 Room temperature regulation

08.2013 Ze Bekrer B.IQ

33

B.IQ

PARAMETER / ETS CONFIGUTATION

 Room temperature regulation

08.2013 Ze Bekrer B.IQ

34

B.IQ

PARAMETER / ETS CONFIGUTATION

 Temperature measuring

08.2013 Ze Bekrer B.IQ

35

B.IQ

PARAMETER / ETS CONFIGUTATION

 Room temperature regulation

08.2013 Ze Bekrer B.IQ

36

DESIGN & VERSIONS CONSTRUCTION & DIMENSIONS STRUCTURE OF THE DISPLAY PARAMETER

TECHNICAL DATA 08.2013 Ze Bekrer B.IQ

37

B.IQ

TECHNICAL DATA Supply Controls and displays Internal temperature sensor Internal clock

Voltage (via bus line): Power consumption (via bus line): Rockers (buttons) Graphics display with 2 display buttons Measuring range Resolution Air humidity Resolution Gang variation

Connections Index of protection Ambient temperature range Flush-mounted bus coupling unit plus (7504 00 03)

IP 20 Mode Storage / transportation

Assembly Mounting orientation Dimensions (W x H x D) 08.2013 Ze

Plug into flush-mounted bus coupling unit any depending on design

Bekrer B.IQ

21 –32 V DC typically 360 mW 3-5 (6-10) Two lines with symbol bar 0 ° C to 40° C 0.1 K 0% to 95% (non-condensing) 1 minute max. 8 minutes a day (use external clock!; update every hour over the bus) User interface: 2 x 5-pin male connector -5 to +45 °C -20 to +60 °C (storage at over +45°C will reduce the working life) see dimensional drawings

38

Thanks for your attention 08.2013 Ze Bekrer B.IQ

39