Petroleum Tank Technologies (PTT) Underground Petroleum
Download
Report
Transcript Petroleum Tank Technologies (PTT) Underground Petroleum
Petroleum Tank Technologies (PTT)
Underground Petroleum Storage Tank (UPST) FRP Lining
Background
Leakage from an Underground Petroleum
Storage Tank poses a significant risk to
- Persons,
- Property,
- Environment, and
represents a major liability for the occupier /
owner of the premises
Risk
Litigation
Licence
Fines
Reputation
Sales
Environment Remediation Cost
Loss of Strategic Site
Risk
Ageing single wall UPSTs represent an
increasing environmental and financial risk
--------------------------------
Tanks refurbished in Japan using the
UV Curable FRP Lining
have not had a single warranty claim
– many have been lined for more than 10 years
To date, PTT has refurbished tanks in several states, some of which are included below:
Distributor
◈ Shell Distributor:
Customer
Belven Enterprises Pty. Ltd.
Location
Collie WA
Tank Size & Q'ty
33,000 litres x 1 ea
27,000 litres x 1 ea
18,000 litres x 1 ea
11,500 litres x 1 ea
55,000 litres x 1 ea
45,000 litres x 2 ea
18,000 litres x 1 ea
27,000 litres x 1 ea
9,500 litres x 2 ea
◈ Mobil Distributor:
TASCO
Mildura VIC
17,000 litres x 1 ea
45,000 litres x 2 ea
18,000 litres x 1 ea
13,600 litres x 2 ea
12,000 litres x 1ea
45,000 litres x 2 ea
10,000 litres x 1 ea
27,800 litres x 1 ea
42,000 litres x 2 ea
27,000 litres x 2 ea
Benefits of UV Cured FRP Lining
Extends the life of the UPST by at least 20
years – Guaranteed
Suitable for Ethanol storage up to 100% by
the standard use of a final coating of Novolac.
Permanent manhole makes future
cleaning and inspections simple
Benefits of UV Cured FRP Lining
Automatic inventory monitoring can be
established via the manhole (ATG system)
Service Station continues to operate
during the tank relining
Average tank repaired in a week
Benefits of UV Cured FRP Lining
Leaking tanks can be repaired
- EPA guidelines must be met,
- Site of the tank is critical,
- Strict environmental assessment
process is followed.
Work Procedure
Install temporary
enclosure
Empty fuel tank
Cut concrete
Cover sludge with detergent mix
Work Procedure
Purge Tank, reducing the atmosphere to zero
% LEL, and zero % VOC’s.
Cut access hole in tank
Tank is cleaned
Waste disposed of as per regulations
Work Procedure
Tank is inspected, ultrasonic thickness test.
Testing is over entire internal surface, in a
grid of 50 cm. squares.
Assessed for suitability for repair
Work Procedure
FRP Lining is applied
Sheets overlap
Joins are sealed
FRP Lining is cured by UV light
Work Procedure
Ethanol resistant
coating applied
Tank is pressure tested
at 35 KPa
Reinforcement and
concrete is replaced
Manhole cover is fitted
Petroleum Tank Technologies
Underground Petroleum Storage Tank (UPST) FRP Lining
Cost Effective
Minimum loss of Retail Sales
20 Year Guarantee
Minimal Duration or Disruption
Safe Procedure
Competent Operators
Professional Service