TG20 eGuide.
Download
Report
Transcript TG20 eGuide.
Introducing TG20:13
1
Introducing TG20:13
Official launch - 22nd November 2013 at the NASC AGM, Bristol
‘A comprehensive guide to good practice for tube and fitting
scaffolding’
2
Work at Height Regulations 2005
Schedule 3 – part 2 additional requirements for scaffolding
7) Strength & stability calculations for scaffolding shall be
carried out unless…
a) A note of calculations, covering the structural
arrangements contemplated is available; or,
b) It is assembled in conformity with a generally
recognised standard configuration.
3
HSE Support
‘The Work at Height Regulations 2005 require that
strength and stability calculations are carried out for
scaffolds unless they conform to a recognised standard…
…HSE is pleased to acknowledge that TG20 has been
written by NASC to provide such a standard…’
Heather Bryant, Chief Inspector of Construction
Health and Safety Executive
4
UKCG Support
‘We applaud and support the work of
the NASC which will no doubt result in
safer scaffolding…
The UKCG recommend the adoption
and standardised use of TG20:13…
both within and outside the
construction sector.’
Stephen Ratcliffe,
Director UK Contractors Group
5
TG20 Compliant Scaffolding
TG20 compliant scaffolds have been
designed by structural calculation in
accordance with BS EN 12811.
Design advice should be sought for
any scaffold outside of the scope of
TG20 Compliant Scaffolding.
TG20 compliant scaffolds were
previously referred to as ‘Basic’ or
‘Standard’ Scaffolds.
6
TG20 Compliance Sheets
Demonstrates compliance
and that bespoke design is
not required.
Typical Scaffolds included
in TG20:13 Operational
Guide (Chapter 03).
Wider variations included
in the TG20 eGuide.
Design advice must be
sought for any scaffold
outside the scope of a
TG20 Compliance Sheet.
7
Simplified Wind Classifications
Wind exposure affects the maximum height and
tie duty, especially when sheeted or netted.
A simple wind exposure classification illustrated
here is used with the TG20 Compliance Sheets
(chapter 3)
A more accurate wind analysis is used in the
TG20 eGuide, which can result in increased safe
heights and reduced tie duties.
Further advice is provided for designers in TG20
Design Guide.
Wind exposure is classified as ‘moderate’, ‘high’
or ‘extreme’
Other factors to be considered are ‘site
topography’, ‘seasonal variations’ and ‘wind
shielding in cities’
8
Compliant Scaffolding Types
Tied Independent Scaffolding
9
Compliant Scaffolding Types
Towers
10
Compliant Scaffolding Types
Interior Access Birdcage Scaffolding
11
Compliant Scaffolding Types
Tied Putlog Scaffolding
12
Compliant Scaffolding Types
Free-standing Independent Scaffolding
13
Compliant Scaffolding Types
Loading Bay
14
Compliant Scaffolding Types
Ladder Access Tower
15
Compliant Scaffolding Types
Chimney-stack Scaffolding
16
Compliant Scaffolding Features
17
Compliant Scaffolding Features
Bridging with Beams
18
Compliant Scaffolding Features
Prefabricated Transom Units
19
Compliant Scaffolding Features
Light duty protection fans
20
Compliant Scaffolding Features
Pavement Lifts
21
Compliant Scaffolding Features
Cantilevered Access Platforms
22
Compliant Scaffolding Features
Inside Board Bracket Platforms
23
Tube
TG20 Compliant Scaffolds only permits the
following types of tube to be used:
BS EN 39 type 4 (4mm) galvanised steel
tubes or equivalent
High-tensile galvanised steel tubes with a
diameter of 48.3mm, thickness of 3.2mm,
in accordance with BS EN 10210-1
The following types may not be used
without design:
BS EN 39 type 3 steel tubes
Aluminium tubes
Other dimension, material or grade
24
Scaffold Boards
Platforms constructed from timber boards or decks of other materials
BS2482 Timber board (softwood)
BS2482 Board (with nail plate option)
LVL Board (Laminated Veneer Lumber) Composite Plastic Board
25
NASC Yearbook
Summary in the TG20:13 article in the Yearbook
26
TG20 eGuide Demonstration
27
www.nasc.org.uk
28