RO Demineralisers, Medium Flow Water Treatment Division

Download Report

Transcript RO Demineralisers, Medium Flow Water Treatment Division

RO Demineralisers, Medium Flow
Demineralisers Medium Flow. Units available
Mod. 4VA0X00: Cancelled
•
•
•
•
Many membranes replaced in guarantee
period.
Corrosion problems due to high salinity
Chlorine remover filter insufficient (chlorine
damages the membranes)
Few pre-treatments available
Low
Salinity
Production
(m3/day)
4VA0100
2.5
4VA0200
5
4VA0300
10
4VA0400
20
Water Treatment Division
RO Demineralisers Medium
Demineralisers Medium Production Capacity. Units available
Mod. 4DAXX00: Available
•
•
•
•
Low
Salinity
High
Salinity
Production
(m3/day)
Membranes
4DA1100
4DA2100
4-6
1
4DA1200
4DA2200
8-12
2
4DA1300
4DA2300
14-18
3
4DA1400
4DA2400
20-22
4
Equipments to process water from wells and brackish water,
suitable to treat up to 2.500 mg/l (low salinity) and 9.000 mg/l
(high salinity) of TDS, respectively.
It can be mounted in a small cabinet Mod. 4045500
Optional production capacity increase with adittional
membranes (1-4)
Options: Chlorine remover filter, silex filter, iron remover
filter, organic matter filter. Biocide doser, Bisulfite and water
softener for boilers.
Iron remover
Filter
Silex-antracite Chlorine
Filter
remover
Filter
Organic Matter
Filter
Biocide
Doser
Bisulfite
Doser
Water Treatment Division
RO Demineralisers Medium
Models 4DAXX00. Main Features:

Antiscalant doser instead of a water softener with salt.

Antiscalant automatic mixture preparation.

Backwash with demineralised water instead of feeding water.

Advantages due to the use of antiscalant:


Ecological: No brine from the water softner regeneration



Logistics and easy use: no need to stack salt bags and simplicity
Cheaper: antiscalant is cheaper than salt consumption
Expansion of the action capacity: wide espectrum
Balance in the ratio production/surface & reject/surface of the membrane
compared with the old existing equipments.
Water Treatment Division
RO Demineralisers Medium
Models 4DAXX00. Main Features:

Quality of components:
•
•
•
•
•
•
Programmable PLC Siemens S7-200
Centrífugal Pump Grundfos
Metering Pump Prominent
Stainless steel frame quality AISI-304
Piping of High salinity range in stainless steel AISI-316
Toray membranes: TMG10 (Low salinity), TM710 (High salinity)

Production can be upgraded just by adding membranes to the existing
equipment (no need to buy a full new system).

Suitable cabinet assembly

Wide range of pre-treatments available:
Water Treatment Division
RO Demineralisers Medium
Models 4DAXX00. Example of anomaly
Just like a car, the models 4DA have two types of alarms to inform us about any
possible failure and its seriuosness.
CAR
DEMINERALISER
TYPE OF
ALARM
EXAMPLE
ACTION
EXAMPLE
ACTION
NOT
CRITICAL
Windscreen
wiper water
shortage
Amber light:
to stop in a
few miles
Flow of
demineralised
water production,
product dosing.
Failure warning,
failure record and
equipment stop
after 10 days.
CRITICAL
Motor oil
shortage, brake
fluid shortage
Red light:
immediate
stop
Water shortage,
levels, overcurrent.
To stop the
equipment
Water Treatment Division
RO Demineralisers Medium
Models 4DAXX00. Main Features:
Buzzer included to alert the customer about
the failures.
•
•
•
•
The equipment must recognize the
adverse conditions to assure a long
operational life.
The demineralisers are equipments
overlooked by the customer (is a non
productive equipment) and usually there
is not a preventive maintenance of these
installations.
The equipment will stop only if there is an
imminent risk to its operating life,
avoiding irreversible and expensive
damages.
The customer must be informed of any
anomaly (critical or not) without
decreasing the business.
Buzzer
Light Alert
Water Treatment Division
RO Demineralisers Medium
Demineraliser. Size.
Height 2.000 mm
Width 480 mm
Length 1.550 mm
It is possible to be installed in cabinet Ref.
4033500 (size with cabinet: Height 2.100 mm x
Width 1.500 mm x Depth 900 mm
Water Treatment Division
RO Demineralisers Medium
Demineraliser. Available Configuration
Assembly in Plant Configuration
Water Treatment Division
RO Demineralisers Medium
Maintenance of Demineralisers 4DAXXXX
1.- Daily maintenance
2.- Every week
To check the level of chemical
product.
To check and to take note of
pressures and flows.
3.- Every 3 months
4.- Every 6 months
To check the condition of the filters (FS1
& FS2), if necessary they should be
changed.
To clean the small tanks of
anti-scalant and backwash
water.
Water Treatment Division
RO Demineralisers Medium
Example of calculation of Antiscalant vs Water Softener
Antiscalant dosage
Water softener 2x100 litres
Consumption of antiscalant product:
Salt Consumption:
– Daily need of water: 21 m3 at 70 ºHF
(39,2ºHD).
– Necessary regeneration of the water softener
every 9 m3
– Number of regenerations per day: (21m3/day)
/ (9m3/ regeneration) = 2.3 regenerations /day
– Consumption of salt per litre of resin in every
regeneration: 0,2 kg/Litres of resin
– Consumption of salt in every regeneration: 0,2
kg/Litre of resin x 100 Litres of resin = 20 kg of
salt per regeneration
– Salt consumption per day: 2.3 regenerations /
day x 20 kg of salt/regeneration = 46 kg/day
– Salt consumption in the same period of
time (124 days): 46 kg/day x 124 days =
5. 704 kg = 228 sacks of 25 kg
– Daily need of water: 21 m3 at 70 ºHF
(39,2ºHD).
– “High” dosage of product: 5 mg/L = 5 g/m3
– Daily product consumption: 21m3 x 5 g/m3 =
105 g/day = 0.105 kg/day
– 1 carafe 10 L = 13 kg
– So 1 carafe of 10 litres of antiscalant will
last: 13 kg / 0.105 kg/day = 124 days
Water Treatment Division
RO Demineralisers Medium
Example of calculation of Antiscalant vs Water Softener
Conclusion: In 124 days of use:
5.704 Kg of salt
=
1 bottle of 10 L (13 Kg)
Make yourself your calculations:
Price/kg Salt x 5.700 kg salt = Euros spent on salt
versus
PVP 10 L Antiscalant carafe = 189 ,00 Eur
Water Treatment Division
RO Demineralisers Medium
Difference between antiscalant and water softener.
Antiscalant doser
system
+
Antiscalant drum
Water softener
+
Salt
Water Treatment Division
RO Demineralisers Medium
Car Wash
Equipment
M-7
M-9
M-15
Equipment
performance
Equipment
performance
Equipment
performance
Equipment
performance
5m3/day
10m3/day
15m3/day
20m3/day
4DA1100 – Low salinity
4DA2100 – High salinity
4DA1200 – Low salinity
4DA2200 – High salinity
4DA1300 – Low salinity
4DA2300 – High salinity
4DA1400 – Low salinity
4DA2400 – High salinity
+ accumulation
tank
= 5 m3
+ accumulation
tank
= 10 m3
M-18
+ accumulation
tank
= 15 m3
4TB0100
4TB0400
+ accumulation
tank
= 15 m3
Range:
All R.O. equipments must be installed with a pretreatment
stage according to the intake water quality !
Low salinity: 0 ppm– 2.500 ppm
High salinity : 2.500 ppm – 9.000 ppm
Water Treatment Division