Transcript Document

MODUL 3
Sentral SPC Digital
1
TUJUAN
Memahami arsitektur sentral SPC digital,
bagian-bagian/komponen dan fungsi masingkomponen
Memahami prinsip kerja sentral SPC digital
dalam proses panggilan (call processing)
2
1. Arsitektur Dasar Sentral Digital
1
4
7
*
2
5
8
0
3
6
9
#
Subscribers
1
4
7
*
2
5
8
0
EXCHANGE
Subscriber lines
(access network)
Subscriber
Line Circuit
3
6
9
#
Switching
Unit
Trunk Circuit
Trunk Lines
(E1/T1)
To/from other
Exchange
Signaling
Unit
Control Unit
3
2. Unit-unit fungsional sentral dig
GROUP SWITCH UNIT
TRUNK
DLTU
digital
DLTU
M
D
F
Sub Line
Term Unit
M
U
X
Sub
Concen
Switch
Block
CAS
MF Sig
Swblk
Control
SUBSCRIBER
CONCENTRATOR UNIT
Group
Switch
Block
Analogue
Trunk
Term Unit
CCS
Tones
MF
Sig
DLTU
D
D
F
analogue
Tones &
ann
Swblk
Control
Exchange-control system
4
3. Sentral Telepon Digital EWSD
Hardware Structure
Access
Switching
LTG
GP
Divided into 4 functions :
– Access unit (Access Unit)
– Switching Unit
(SN=Switching Network)
– Common Channel
signalling Network Control
– Control Unit (CP =
Coordination Processor)
DLU
DLUC
LTG
GP
Common Channel
Signalling
CCNC
CCNP
SN
Coordination
Processor
SYP
SYPD
SSP
MB
MBC
CCG
SGC
5
A. Access Unit
•
•
As an interface between
subscriber line or trunk
with central (Exchange)
Consists of :
– Digital Line Unit (DLU)
– Line Trunk Group (LTG)
LTG A
Analog
Subscriber Line
GP
SLMA
DLU
LTG B
SLM
ISDN
Subscriber Line
GP
LTG C
Trunk Digital
SN
GP
CCNC
CCNP
CP
O/M
SGC
6
1)
•
•
•
LTG (Line Trunk Group)
As connector between analog or digital device(antara perangkat analog atau digital
yang berada di luar sentral EWSD dengan Switching Network.
Pada LTG dapat terpasang saluran pelanggan, Trunk dan Digital Switch Board
(DSB)
Sentral EWSD mempunyai 4 macam (tipe) LTG
– LTGA
• Digunakan untuk saluran pelanggan analog
• Tiap unit LTGA mempunyai 8 buah LTU (Line Trunk Unit)
• Kapasitas tiap unit LTGA : 256 port pelanggan
– LTG B
• Merupakan terminasi ke :
– DLU (Digital Line Unit)  untuk mencatu pelanggan (analog/digital).
– DSB (Digital Switch Board)  untuk layanan khusus (special service) melalui operator seperti layanan
informasi nomor telepon/billing, sambungan interlokal/internasional, pengaduan gangguan dll.
• Kapasitas tiap unit LTGB = 4 sistem PCM-30 (= 4x30 kanal voice)
– Untuk aplikasi DLU : maksimal dapat melayani hingga 952 pelanggan analog
– Untuk aplikasi DSB : dapat dipasang 30 terminal/meja operator (switchboard)
– LTG C
• Merupakan saluran sirkit trunk digital  4 DIU (Digital Interface Unit)
• Dapat dihubungkan dengan 120 trunk digital
– LTG D
• Digunakan untuk trunk digital internasional menggunakan transmisi sateli, dilengkapi echo
canceller
7
a)
The Parts of the LTG (Line Trunk Group)
Consists of :
•
Group Prosesor (GP)
–
–
–
–
–
•
LTU n
GS
atau
SPMX
8 Mbit
LIU
Connector for Functional units in LTG subscriber
Connector for Functional units in LTG  Trunk connector
SU
Signalling Unit (SU)
–
•
Connector EWSD with PCM transmission System
Speech Multiplexer (SPMX)
–
•
Costumize subscriber line/trunk with LTG
Group Switch (GS)
–
•
LTU 1
Digital Interface Unit (DIU)
–
•
2 Mbit
Line Trunk Unit (LTU)
–
•
Set the signalling Procedures
Set the SLC and LTG
Supervision, Metering for call processing
Organize and process data exchange with CP
Scanning LTG ports
For Signalling process trunk and Subscriber
Link Interface Unit (LIU)
–
–
–
GP
Mengadakan cross office check
Syncronization bits received SN
Adjusting (menyesuaikan) clock with CCG
8
2)
DLU (Digital Line Unit)
Digital Line Unit
Analog
Subscriber
• As a analog, digital, and PABX
termination subscriber line.
• Maximum capacity 952 subscribers Digital
linked to EWSD central office via 4 x Subscriber
PCM highway (120 Channels)  2
LTG for increased availability
• Can be placed one location with a
main or as a remote central
• DLU Units :
–
–
–
–
–
–
–
–
Subscriber Line Module Analog (SLMA)
Subscriber Line Modul Digital (SLMD)
Ring Generator dan Metering Generator
(RGMG)
Digital Interface Unit for DLU (DIUD)
Digital Line Unit Control (DLUC)
Test Unit (TU)
Emergency Module for Pushbutton
Subscriber (EMSP)
External Alarm Set (ALEX)
SLMA
RGMG
SLMD
EMSP
TU
DIUD
LTGB
ALEX
DLUC
9
B.
SN (Switching Network)
• SN merupakan bagian yang bertugas melaksanakan proses
penyambungan saluran-saluran yang terhubung padanya
• Ada 2 prinsip penyambungan yang digunakan : time switching dan
space switching
• SN terdiri dari 3 modul switching :
–
–
–
–
Time Stage Module (TSM), parameter 4/4  input,4/4  output
Space Stage Module (SSM), parameter 16/16
Space Stage Module (SSM),parameter 8/15  input, 15/8  output
SN  DE3 : 4 TSM dan 1 SSM didupliksdi SN0 dan SN1, kapasitas
pelanggan : 3000 pelanggan dan 1500 trunk
– SN  DE4 :16 TSM dan 4 SSM, kapasitas pelanggan : 12000
pelanggan dan 7500 trunk
– SN  DE5 : 16 TSM yang tergabung dalam satu Time Stage,
kapasitas pelanggan : 100.000 pelanggan dan 60.00 trunk
– Time Stage Group (TSG) dan satu Space Stage Group (SSG) yang
merupakan gabungan dari 16 SSM 8/15 dan 15 SSM 16/16, TSG di
duplikasi dan mempunyai satu SGC
Catatan : DE = Digital Exchange
10
a)
Tipe-tipe SN
i.
SN DE3
• Untuk sentral kapasitas kecil (max 5000 sst)
• Biasanya berupa/tipe container (box)
11
ii. SN DE4
• Untuk sentral dengan kapasitas sedang (max 15.000 sst)
• Tipe instalasi dalam gedung (building)
12
iii. SN DE4
• Exchange with high capacity (until 150.000 sst)
• Type : Building
13
C.
CP (Coordination Processor)
Fungsi CP :
–
–
–
–
–
–
–
–
Analizing number ruting and zoning
Operation and maintenance Exchange
Routing for call processing
Giving alternatif route
Analizing and send message for line/trunk
Trafik measurement
Data Billing
Menyekat peralatan yang rusak
MB
CCG
IOP
Functional Units
–
Siemen Switching Processor (SSP):
•
•
•
–
PU
MU
BA
Sebagai interface peripheral processor (GP, DLUC, SGC) dengan PU
Central Clock Generator (CCG)
•
–
Processing Unit (PU)
Memory Unit (MU)
Input/Output Processor (IOP)
Message Buffer (MB)
•
–
BEU
Pengmbangkit clock sentral
Input/Output Device
•
•
•
SYPC (System Panel Control)
Terminal Input/output : PT 88, PT 80 dan VDU (Video Display Unit)
External Memory : MDD (Magnetic Disk Device) atau MTD (Magnetic Tape Device)
14
D.
CCNC (Common Channel signaling
Network Control)
Secondary Digital
Carrier( SDC)
8 Mbps
– Bagian yang berfungsi
meproses pensinyalan CCS
No. 7.
– CCNC dihubungkan langsung
dengan CP.
– Sinyal yang datang dari
sentral lawan setelah diolah
CCNP (CCNC Processor)
dapat ditransfer langsung ke
GP atau diserahke CP
LTG
Common
Signaling
Channel ( CSC)
SN
GP
LTG
GP
LTG
GP
CCNC
CP IOP
MB MB
Signalling Transfer Part (STP)
Signalling End Point (SEP)
15
E.
Konfigurasi lengkap sentral EWSD
Switching
Local
Application
DLU
SN 1
SN 0
LTGB
DLUC
GP
LTGC
Remote
Application
DLU
GP
LTGB
DLUC
GP
Dari/ke
sentral lain
LTGC
DLU
LTGB
DLUC
GP
GP
LTGB
DLU
GP
DLUC
LTGC
GP
Common Channel
Signaling
CCNC
SGC
CCNP
MB
EM
SYP
MBC
SYPC
speech path
CP
control path
OMT
CCG
16
4. Pembangunan hubungan (1)
1
4
7
*
2
5
8
0
LTG
DLU
3
6
9
#
SLM
SLCA
GS
DIUD
SN
LIU
DIU
COC
A-Subscriber
SU
SLMP
DLUC
TOG
CR
GP
DLU
1 2 3
4 5 6
7 8 9
* 0 #
Ringing
current
LTG
SLM
SLCA
GS
DIUD
LIU
DIU
B-Subscriber
SU
TOG
SLMP
DLUC
CR
Ringing
tone
GP
Control signals
Checks
Dial tone & dialled information
Ringing current & ringing tone
Voice connection
CP
SGC
17
4. Pembangunan hubungan (2)
DLU
1
4
7
*
2
5
8
0
LTG
SN
SLMA
3
6
9
#
GS
10a
A-Subscriber
9
SLCA
DIUD
LIU
DIU
COC
15b
6b
1
3
SU
2
SLMCP
TOG
7d
CR
DLUC
8c
5
10b
7a 7b 10c 8d 8b
8a
4
6a
11 16
15a
12
GP
22
LTG
DLU
1 2 3
4 5 6
7 8 9
* 0 #
SLMA
Ringing
current
GS
26
SLCA
DIUD
Ringing
current
B-Subscriber
22a
21b
18 21a RGE
SLMCP 22b
LIU
DIU
23b
SU
TOG
23a
DLUC
20
Ringing
tone
CR
24b
17b
21 17a
25a
19 24a
27
GP
Control signals
Checks
Dial tone & dialled information
Ringing current & ringing tone
Voice connection
13
CP
14
SGC
18
4. Pembangunan hubungan (3)
CALL PROCESSING
(DALAM SENTRAL)
1. A mengangkat hs  SLMCP mendeteksi (berdasarkan hasil scanning pada SLCA)
2. SLMCP meneruskan pesan tsb ke DLUC
3. DLUC meneruskan ke GP (melalui DIU)
4. GP memeriksa data A (EQN, COS/restriction) dan memilih kanal (ts) untuk hubungan
5. GP memberitahu ts ke SLMCP
6a.GP mengaktifkan ts pd GS dan melakukan tes koneksi antara LTG – pel A dg mngirim test tone (6b) dari TOG ke
GS-DIU-DIUD-SLCA
7. Hasil test diterima CR, diterjemahkannya dan diteruskan ke GP
Jika hasil tes ok, maka GP :
8a. Memerintahkan SLMCP utk mengaktifkan ts dan menghubungkannya ke A
8b. Mengaktifkan sumber nada pilih (pd TOG) dan mengirimkannnya ke A (8c)
8d. Mempersiapkan CR utk menerima sinyal digit (no tlp B) dari A
9. SLCA meneruskan nada pilih ke A dalam format analog
10a. Pelanggan A mendial digit B
10b. Sinyal digit diterima CR, diterjemahkannya dan diteruskan ke GP (10c).
11.Saat digit prtama diterima, GP memerintahkan utk menonaktifkan ts utk jalur nada pilih (mnghentikan nada pilih)
12.Jika semua digit tlh diterima GP, maka GP meneruskannya ke CP disertai data lainnya ttg A yg diperlukan CP
13.Memeriksa data base B tentang :
- COS & SCOS pelanggan B.
- Lokasi hardware B (identitas LTG-B, DLU-B, SLMA-B dan port B pd SLMA)
- Status (bebas/sibuk)
Jika B bebas, maka :
19
4. Pembangunan hubungan (4)
14. CP memilih jalur (ts SN) utk menghub LTG-A & LTG-B serta mengirimkannya ke SGC dan juga memerintahkan GP
untuk melakukan COC
15a. GP memerintahkan LIU utk melakukan COC (15b).
Jika COC ok, maka :
16. GP-A menset ts pada GS utk speech path A-B dan memberitahu GP LTG-B ttg hub yang terbentuk
17a. GP-B menandai ts utk speech path tsb di sisi B dan
17b. Memberitahu SLMCP-B ttg ts tsb dan
18. SLMCP-B mengaktifkan ts tsb pd SLCA-B
19. GP-B mengaktifkan ts (pd GS) utk hub tsb.
20. GP-B memerintahkan cek jalur (test tone dari TOG-DIU-DIUD-SLCA-B)
Jika hasil cek ok, maka :
21. GP-B memerintahkan :
- DLUC utk kirim ringing current (ke B)
- TOG utk kirim ringing tone (ke A)
22. Jika B menjawab (hasil scanning SLMCP-B (22a)), maka
22b. SLMCP-B melaporkannya ke DLUC-B
23. DLUC-B menghentikan ringing current dan juga melaporkan bhw Btlh mnjawab ke GP-B.
24a. GP-B menghentikan ringing tone (dg menonaktifkan ts pd GS) dan
24b Mengaktifkan ts untukjalur bicara
25a. GP-B mengirim message “answer signal” ke GP-A untuk keperluan charging (metering)
26. Selama proses pembicaraan, kedua GP memonitor kedua pelanggan (melalui SLMCP dan DLUC)
27. Saat akhir pembubaran data charging/meter ditransfer dari GP-A ke CP
20
5. Sentral STDI-K
SPCH 0
SPCH 1
SLMA
SLMA
CB 0
DLUC-R0
Terminal
PCDL M
PC
CB 1
DLUC-R0
Floppy disk
TU
Hard disk
SUR
PCM links
to distant
exchange
DIUD-R0
DIUD-R1
PCM links
to distant
exchange
21