the best dedicated THGA furnace system AAnalyst 600 AA

Download Report

Transcript the best dedicated THGA furnace system AAnalyst 600 AA

AAnalyst 600

ES Hwang Inorganic Product Specialist PerkinElmer Korea

AAnalyst 600…

Features

• • •

Dedicated THGA furnace High sensitivity segmented solid-state photodiode detector Simultaneous measurement of sample and reference beams

Transversely heated graphite furnace

Longitudinal Zeeman effect background correction

Benefits

THGA furnace reduces interferences in difficult matrices

Exceptional analytical performance and detection limits

Highest Long-term Stability

Minimized interferences and memory effects

Shorter analysis time (fast furnace programs)

Best possible background correction with no light loss

… the best dedicated THGA furnace system

AAnalyst 600

AA Spectrometers

AAnalyst 600

Revolutionary Optical System

AAnalyst 600

Unique Features

 First AA spectrometer •

Integrated furnace

Zeeman-THGA graphite furnace

AAnalyst 600

Unique Features

 First AA spectrometer •

8-lamp holder

Automatic lamp selection and adjustment

Built-in power supplies

Hollow cathode lamps

Electrodeless discharge lamps

AAnalyst 600

Highly Versatile Furnace Autosampler

User Benefits:

Automatic generation of reference solutions

Automatic multiple injections

Automatic dilution

Automatic injection into a preheated tube

Variable pipetting speed

Ease-of-operation

AAnalyst 600

Revolutionary Optical System

Real time double beam system

High sensitivity segmented solid-state photodiode detector

User Benefits:

Exceptional analytical performance

Highest Long-term Stability

AAnalyst 600

Customized Solid-State Detector

 Highest quantum efficiency  Integrated low noise CMOS charge amplifier array  Exceptional signal-to-noise ratio

AAnalyst 600

Quantum Efficiency of Detectors

solid state detector photomultiplier

AAnalyst 600

Furnace (THGA) Instrument Detection Limits

THGA Instrument detection limits (IDL) / pg Element PMT Photodiode As Cr 9 1.5

6 0.4

Cu Mn Pb Tl 5 2 3 7.5

4 1.5

3 7

AAnalyst 600

Automatic Lamp Selector

 8-Lamp holder  Built-in power supplies for hollow cathode and electrodeless discharge lamps  Automatic alignment, element, wavelength and slit selection

AAnalyst 600

Unique Overall Conception

Total system control via AA WinLab32 software for highest versatility and simplest operating convenience

• • • •

Atomizer control Lamp and lamp current control THGA control Accessory control

AAnalyst 600

Unique Software Conception

Automatic system setup from stored user’s methods

• •

Direct from Workspace

Method

Sample information

Individual screen design, window selection etc.

User Benefits:

Analytical reliability

Ease-of-operation

Time-saving

WinLab32 for AA

Bringing a new level of productivity to high-performance AA

AA WinLab32 - Features and Benefits

Improve productivity

• • • • • • •

Data Reprocessing * WinLab32 Offline * Priority samples * Append to Analysis List * Edit Calibration Recall Calibration Furnace Method Development wizard *

Improve ease of use and reduce training

• • • •

Tool tips (available in 6 languages) * Wizards * Analysis List * AS-93 parameters integrated * * New features not present in 16-bit AA WinLab

AA WinLab32 - Features and Benefits

Reduce training and support

• •

Common look and feel with WinLab32 for ICP-OES CD Document Pack

Improve stability and data accessibility

Access database *

Method and data security

• • • •

Password protection * Multiple user levels * Data check sums to detect changes * 21 CFR Part 11 Compliant * New features not present in 16-bit AA WinLab

WinLab32 for AA Workspace

Toolbar Automated Analysis Status Monitor Results Calibration

Common look and feel with WinLab32 for ICP for easy cross platform training

Data Reprocessing

     

Recalculation of analytical data

• • •

Correct SIF errors Change calibration function Delete replicate(s) Performed using the raw data Samples can be reprocessed in any sequence Original data are preserved Analytical log can be printed Reprocessed data are identified

Data Reprocessing

Status display Select samples in the order you want them reprocessed.

Change sample information in these columns

Furnace Method Development Wizard

Define Furnace Steps to cycle Temperatures Analyze Solutions and Display Results

Align Autosampler Tip Wizard

Auto dilution by system

Priority Sample

Samples can be added without interrupting current analyses

Exporting Data to LABWORKS

WinLab32 Enhanced Security Option

   

Enhancement to WinLab32 for AA (and ICP) Significant set of new features

• •

Audit trails File versioning Enable compliance with new regulations

• • •

21 CFR Part 11 - Pharmaceutical 40 CFR Part 3 - Environmental (proposed) Others Primarily for highly regulated laboratories

Users actions are restricted

• • •

Increased storage space requirements Additional information entry requirements Requires more system housekeeping

AAnalyst 600

Total Range Graphite Furnace AA

THGA-type furnace with Zeeman-effect background correction

User Benefits:

Selection of the best system for individual requirements and budgets

High performance, near interference-free trace analysis with STPF concept

AAnalyst 600

Integrated THGA Furnace System

AAnalyst 600

Zeeman THGA Furnace

Transversely heated graphite furnace

Longitudinal Zeeman effect background correction User Benefits:

Exceptional detection limits

Minimized interferences and memory effects

Best possible background correction

Mimimum sample preparation time

Shorter analysis time (fast furnace programs)

AAnalyst 600

Integrated THGA System

   

THGA Concept: more than 2500 systems in use Longitudinal Zeeman Effect: highly resolved background compensation without light loss DC furnace power supply Closest approach to the "ideal system"

AAnalyst 600

Integrated THGA System

0 .1 2 5 0 .1 0 0 0 .0 7 5 0 .0 5 0 0 .0 2 5 0 .0 0 0 0 1 2

Atomic and background signals for Ba, 20uL, 25 ug/L

A A -B G B G 3 4 T im e / s 5 6 7 8

AAnalyst 600

Zeeman versus D

2 Background Correction

     

Background correction independent of wavelength True double-beam with only one optical path Baseline noise at least 2x lower Optical resolution

Dl

is 100x better Char. mass typically 10 and 20 % poorer than with D 2 m 0 for the worst case, Cu, is 50% poorer) (the Zeeman-effect background correction gives superior detection limits in real samples

AAnalyst 600

Highly Versatile Furnace Autosampler

High-capacity, interchangeable sample trays

88 or 146 sample positions

Full AA WinLab32 control including multi-tasking

User Benefits:

Automatic generation of reference solutions

Automatic multiple injections

Automatic dilution

Automatic injection into a preheated tube

Variable pipetting speed

Ease-of-operation

AAnalyst 600

Flow Injection - Furnace Coupling

Optional accessory for coupling FI-MHS with furnace AA

Software controlled automatic operation User Benefits:

Detection limits in range of ng/L

Time-savings by automatic on-line operation

Less interferences since matrix components are removed in the FI system

AAnalyst 600

Automatic Slurry Sampling

Optional ultrasonic probe integrated in the autosampler

Automatic introduction of solid samples as slurries

Full software control User Benefits:

Reduced sample preparation and analysis time

Reduced potential for contamination

Easy operation

What else can PerkinElmer offer?

Sample Preparation Solutions

• •

Multiwave 3000 High Pressure Asher (HPA)

Flow Injection Technology (FIAS)

• •

For sample pre-treatment Hydride generation

Stand-alone Mercury systems (FIMS)

Sample Introduction Systems

• •

Autodilutors Laser Ablation systems

World class service and support

Inorganic sample preparation….

Multiwave 3000

Reduced digestion times

• • • •

Superior digestion quality Time-saving Easy operation Maximum safety

High Pressure Asher

Complete sample mineralization

• • •

Minimum organic residue No elemental losses No contamination Multiwave 3000 HPA system

…a clear solution for sample preparation !

FIAS – Flow Injection Systems

   

2 Models

• •

FIAS 100 (1 valve, 1 pump) FIAS 400 (1 valve, 2 pumps) Automated sampling for Flame AA

Dilution

• • •

Add reagents or modifiers Matrix removal Preconcentration Improved sample handling

Small sample volumes

High solids samples Hydride generation

Determination of As, Se, Te, Be, Sb, Sn FIAS 100 system FIAS 400 system

Flow Injection Mercury Systems

FIMS 400

Determines Mercury via Cold Vapor AA (CVAA)

• • • • • •

Small footprint Fully automated Easy to operate Stand alone system Cost effective Now with WinLab32 for AA software

AAnalyst 600

Conclusions

Not just another AA!

No compromises!

Easiest, simplest AA furnace

Full automation

Full range of accessories

Power of AA WinLab32 software

Ultimate in performance

The AA instrument to take you beyond 2000...