Transcript PORTABLE FIRE EXTINGUISHER TRAINING Section 1910.157
PORTABLE FIRE EXTINGUISHER TRAINING
Section 1910.157
Montana Department of Labor & Industry
Occupational Safety and Health Training Institute
PURPOSE OF PORTABLE FIRE EXTINGUISHERS?
TO CONTROL OR EXTINGUISH SMALL OR INCIPIENT STAGE FIRES
and
PROTECT EVACUATION ROUTES
MT. Occupational Safety & Health Training Institute
FIRE TRIANGLE
Fire is a very rapid chemical reaction between oxygen and a combustible/flammable material, which results in the release of heat, light, flames, and smoke.
MT. Occupational Safety & Health Training Institute
FOR FIRE TO EXIST, THE FOLLOWING FOUR ELEMENTS MUST BE PRESENT AT THE SAME TIME:
• • • • Enough
OXYGEN
Enough
HEAT
to sustain combustion, to raise the material to its ignition temperature, Some sort of
FUEL
or combustible material, and The
CHEMICAL REACTION
that is fire
.
BEFORE FIGHTING A FIRE
1.WHAT IS BURNING?
2.IS THE FIRE CONTAINED?
3.WHERE IS THE CLOSEST EXTINGUISHER?
4.IS THIS THE CORRECT EXTINGUISHER?
5.WHERE IS THE EXIT IN RELATION TO THE FIRE?
MT. Occupational Safety & Health Training Institute
HOW AN EXTINGUISHER WORKS
MT. Occupational Safety & Health Training Institute
CLASSIFICATIONS
• • •
Class A: “Ash” (Combustibles) Class B: “Barrel” (Flam. Liquids) Class C: “Circuit” (Electrical)
• •
Class D: “Dents” (Metals) Class K: “Kitchen” (Cooking Grease)
MT. Occupational Safety & Health Training Institute
What’s the Cause of this Fire? What Class?
MT. Occupational Safety & Health Training Institute
CLASS LABELING
•
OLDER STYLE of labeling indicating suitability for use on class A, B, and C fires.
•
NEWER STYLE of labeling that shows this extinguisher may be used on ordinary combustibles, flammable liquids, or electrical equipment fires.
MT. Occupational Safety & Health Training Institute
LABELING
For example, a simple water extinguisher might have a label like this… … which means it should only be used on Class A fires.
MT. Occupational Safety & Health Training Institute
TYPES OF EXTINGUISHERS
WATER
•
These extinguishers contain water and compressed gas or air
•
should only be used on class A (ordinary combustibles) fires
MT. Occupational Safety & Health Training Institute
TYPES OF EXTINGUISHERS
CARBON DIOXIDE (CO2)
•
Most effective on class B and C (liquids and electrical) fires.
• •
Suffocates and Cools the fire.
Carbon dioxide is stored as a compressed liquid; As it expands, it cools the surrounding air. Cooling will often cause ice to form around the “horn”.
MT. Occupational Safety & Health Training Institute
TYPES OF EXTINGUISHERS
DRY CHEMICAL
•
Extinguishers are usually rated for multiple purpose use. Class A,B, and C fires.
•
These are filled with foam or powder and pressurized with nitrogen.
•
The greatest portion of this powder is composed of mono-ammonium phosphate.
MT. Occupational Safety & Health Training Institute
TYPES OF EXTINGUISHERS
•
DRY CHEMICAL (cont.)
o o
BC
-
regular type of dry chemical extinguisher. Filled with sodium bicarbonate or potassium bicarbonate.
Leaves a mildly corrosive residue which must be cleaned immediately to prevent any damage to materials. Mono-ammonium phosphate, a yellow powder.
Leaves a sticky residue that may be damaging to electrical appliances such as computers.
MT. Occupational Safety & Health Training Institute
TYPES OF EXTINGUISHERS
KITCHEN OIL AND GREASE FIRES
•
Application wand keeps operator at a safe
•
distance from the fire Safe to used around electrical appliances up to 100,000 volts.
•
Low PH Wet Chemical Agent fine mist discharge helps prevent grease splash and fire re-flash while cooling the appliance
•
Precise extinguishing agent application
•
For use on all cooking appliances
MT. Occupational Safety & Health Training Institute
TYPES OF EXTINGUISHERS
METAL FIRES
•
Used on fires involving metals such as magnesium, titanium, zirconium, sodium, and potassium.
•
Often specific for the type of metal in question.
•
Have no rating nor given a multi-purpose rating for use on other types of fires.
MT. Occupational Safety & Health Training Institute
TYPES OF EXTINGUISHERS
HALON
•
Contains a gas that interrupts the chemical reaction that takes place when fuels burn.
•
Often used to protect electrical equipment - leaves no residue.
•
Limited range, 4 to 6 feet. Initial application should be made at the base of the fire, even after the flames have been extinguished.
MT. Occupational Safety & Health Training Institute
INSPECTION, MAINTENANCE & TESTING
• • • •
Monthly Visual Annual Maintenance Check Empty and Refill – 6 years Hydrostatic – 5 to12 years
MT. Occupational Safety & Health Training Institute
MONTHLY VISUAL INSPECTION CHECKLIST
• • • • • • •
Is each extinguisher in its designated place, clearly visible, and not blocked by equipment, coats or other objects?
Is the nameplate with operating instructions legible and facing outward?
Is the pressure gauge showing that the extinguisher is fully charged (the needle should be in the green zone)?
Is the pin and tamper seal intact?
Is the extinguisher in good condition and showing no signs of physical damage, corrosion, or leakage?
Have all dry powder extinguishers been gently rocked top to bottom to make sure the powder is not packing?
Record the inspection.
MT. Occupational Safety & Health Training Institute
MONTHLY VISUAL INSPECTION
MT. Occupational Safety & Health Training Institute
OSHA Standard 29 CFR 1910.157
The employer shall mount, locate and identify extinguishers so that they are readily accessible.
•
Mount on brackets or in wall
•
cabinets Carrying handle 3-1/2 to 5 feet above floor.
•
Larger extinguishers carrying handle 3 feet from the floor
MT. Occupational Safety & Health Training Institute
MOUNTING & LOCATING
MT. Occupational Safety & Health Training Institute
MOUNTING & LOCATING
MT. Occupational Safety & Health Training Institute
MOUNTING & LOCATING
MT. Occupational Safety & Health Training Institute
MOUNTING & LOCATING
MT. Occupational Safety & Health Training Institute
MOUNTING & LOCATING
MT. Occupational Safety & Health Training Institute
IDENTIFYING LOCATIONS
MT. Occupational Safety & Health Training Institute
TRAINING
• Where extinguishers are provided for employee use: o o o Educational program shall exist
Principles of fire extinguisher use &
Hazards of fire
Training of employee at initial employment At least annually thereafter MT. Occupational Safety & Health Training Institute
USING A FIRE EXTINGUISHER
Steps to follow when responding to incipient stage fires:
•
Sound the fire alarm and call the fire department.
•
Identify a safe evacuation path before approaching the fire.
•
Do not allow the fire, heat, or smoke to come between you and
• •
your evacuation path.
Select the appropriate type of fire extinguisher.
Discharge the extinguisher within its effective range using the P.A.S.S. Technique (pull, aim, squeeze, sweep).
•
Back away from an extinguished fire in case it flames up again.
•
Evacuate immediately if the extinguisher is empty and the fire is not out or if the fire progresses beyond the incipient stage.
MT. Occupational Safety & Health Training Institute
P.A.S.S.
PULL...
seal. Pull the pin. This will also break the tamper AIM...
Aim low, pointing the extinguisher nozzle (or its horn or hose) at the base of the fire. SQUEEZE...
Squeeze the handle to release the extinguishing agent.
SWEEP ...
Sweep from side to side at the base of the fire until it appears to be out. Watch the area. If the fire re-ignites, repeat steps 2 - 4.
MT. Occupational Safety & Health Training Institute
INCIPIENT STAGE FIRE
• • • •
The fire is limited to the original material ignited, It is contained (such as in a waste basket), Has not spread to other materials and The flames are no higher than the firefighter's head.
MT. Occupational Safety & Health Training Institute
MT. Occupational Safety & Health Training Institute
INCIPIENT STAGE FIRE?
MT. Occupational Safety & Health Training Institute
MT. Occupational Safety & Health Training Institute
Do ya have any questions?
MT. Occupational Safety & Health Training Institute
Dan Toney Safety and Health Specialist Montana Dept. of Labor and Industry (406) 247-1035 [email protected]