LUMEN METHOD
Utilization factor
-- Ratio of flux received by reference plane to
total rated lamp flux in the installation.
Utilization factor of a lighting installation
depends only on polar curve of the luminaire,
the room geometry (represented by room
index) and reflectances of the ceiling, wall
and floor.
K. F. Chan (Mr.)
ELEC 3105
1
Maintenance factor –
-- LSF
-- LLMF
-- LMF
-- RSMF
K. F. Chan (Mr.)
ELEC 3105
2
LUMEN METHOD
E= N x n x ø x UF x MF
A
where MF = LLMF x LSF x LMF x RSMF
E =Maintained illuminance, lux