Transcript Slide 1
WIRING DIAGRAM–2 DOORS PoE CF CONTROLLER +12V----- RED 0V ------BLACK D1-----WHITE D0-----GREEN GLED----ORANGE (AY-H020) GLED-----BROWN (RD-J12) GLED-----GREY (AY-Y20B) BUZZ-----PURPLE(AY-Y20B) BUZZ-----YELLOW(AY-H020) RJ45 CONNECTOR COLOUR CODE IN READER OUT READER BUZ TMP NO COM DOOR 2 JP1 JP10 1 2 3 4 5 6 7 8 JP8 NO/NC NORMAL / RESET JP9 RY 2 JP6 RY 1 TAMPER ON KS - 28 Key Switch JP5 Cat 5e cable JP4 Cat 6 cable JP7 DOOR2 JP9-(No jumper) JP10-SHORT JP7-(SHORT) RY 2 NO/NC 12V 0V D1 D0 D1 D0 L1 BZ TP DS PB L2 IN1 IN2 0V 02 C2 01 C1 0V 12V - + 0V D1 D0 1A2A3A GLED TMP 12V 0V D1 D0 BUZ OUT READER 2 DOOR 02 GLED 1 2 3 4 5 6 7 8 TAMPER OFF ON KS - 28 Key Switch MAGNETIC CONTACT 2 NO COM PUSH BUTTON 2 RY 1 + RELAY SETTING closed- power / open- dry contact JP4 is for relay 2 (RY2)SHORT JP4 is for relay 1 (RY1) SHORT FA-102 Emergency Break Glass NO JP2 IN READER 2 BUZ RJ-45 White Green Green White Orange Blue White Blue Orange White Brow n Brow n DOOR 02 NC JP3 NO NC COM 1A2A3A White Orange Orange White Green Blue White Blue Green White Brow n Brow n COM DOOR 1 FA-102 Emergency Break Glass DOOR1 JP5- NO (Normally open) JP6-NO (No jumper) JP8-NO (Normally open) PUSH BUTTON 0V IN2 IN1 L2 PB DS TP BZ L1 D0 D1 D0 D1 0V 12V + OFF MAGNETIC CONTACT D0 D1 0V 12V D0 D1 0V - 12V EM-LOCK 1 GLED GLED Must use with high power POE to supply the controller power to the RJ-45 Network DIRECT CABLE CROSS CABLE 1 2 3 4 5 6 7 8 - Battery Important notes: 1. Kindly turn off the power by switching it and not by pulling the network cable. 2. For 20m connection can use normal cat 5e cable, but for 30m connection please use cat 6 cable. Distance to the door 2 should not more than 30m by using cat 6 cable.