Transcript 132 kV

UPDATE ON ASSETS
IN CESC’S T&D NETWORK
CESC’S
T&D NETWORK
567 Sq. Km. Area
15 nos. 132 kV S/S
88 nos. 33 kV D/S
T&D LINE
(CKT. KM)
132 kV - 267
33 kV - 1194
6/11 kV - 4125
ASSETS IN CESC’S
T&D NETWORK
•CABLES
& O/H LINES
•TRANSFORMERS
•SWITCHGEAR
YARD
EQUIPMENT
CT PT LA
ISOLATOR
CAP. BANK
BATTERY
CABLES & O/H LINES
CABLES & O/H LINES
CIRCUIT KM :
KV
CABLES
TOTAL
186
O/H
LINES
81
132
33
6 & 11
1102
4038
92
87
1194
4125
267
TYPES & SIZES OF CABLES :
KV
CABLE
INSULATION
CONDUCTOR
MATERIAL
CROSS-SECTION
(SQ. MM)
6 & 11
PILC
AL
50, 150, 225 & 300
CU
26, 48, 97, 161 & 645
AL
50, 150, 240 & 300
CU
630
AL
300 & 400
CU
161, 194 & 645
AL
240, 300, 400 & 1000
CU
500 & 630
XLPE
33
PILC
XLPE
132
PILC GAS FILLED
AL
225
CU
150, 161 & 260
XLPE
CU
400, 630 & 800
TRANSFORMERS
TRANSFORMER
POPULATION :
POWER TRANSFORMER
132/33 kV Class :
33 nos.
33/11-6 kV Class :
169 nos.
6/11 kV, 6/3.3 kV Class :
10 nos.
DISTRIBUTION TRANSFORMER
6/0.42 kV Class :
11/0.42 kV Class :
4721 nos.
998 nos.
TRANSFORMER
CAPACITY :
POWER TRANSFORMER
132/33 kV Class :
33/11-6 kV Class :
50, 55, 75 MVA
7, 10, 15, 16, 20 MVA
6/11, 6/3.3 kV Class :
3, 5, 10, 12.5 MVA
DISTRIBUTION TRANSFORMER
6/0.42 kV Class :
11/0.42 kV Class :
100, 200, 315, 400, 600 kVA
315 kVA and 400 kVA
TRANSFORMER
AGGREGATE CAPACITY :
POWER TRANSFORMER
• 132 kV - 1932 MVA
• 33 kV
- 2470.5 MVA
• 6/11 kV - 59.5 MVA
DISTRIBUTION TRANSFORMER
1936.5 MVA
TRANSFORMER
%Z, BIL AND VECTOR GROUP :
POWER TRANSFORMER
132/33 kV Class : 15%,
650 kVp, YNd1
33/11-6 kV Class : 8-11%, 170 kVp, Dyn11
6/11, 6/3.3 kV Class : 10%,
75 kVp,
YNyn0d1
DISTRIBUTION TRANSFORMER
6/0.42 kV Class : 4-5%,
11/0.42 kV Class : 4-5%,
75 kVp,
75 kVp,
Dyn11
Dyn11
TRANSFORMER
TAP CHANGER :
POWER TRANSFORMER
REACTOR
TYPE
VARIETY
132/33 kV
33/11-6 kV
45
1
RESISTOR
TYPE
VARIETY
33
8
121
8
6/11, 6/3.3 kV
TAPLINK
3
10
DISTRIBUTION TRANSFORMER
ALL TAP-LINK
TRANSFORMER
NEUTRAL EARTHING :
POWER TRANSFORMER
132/33 kV Class :
33/11-6 kV Class :
6/11, 6/3.3 kV Class :
HV N – SOLIDLY EARTH
LV SIDE – EARTHED THRU ET
LV N – SOLIDLY EARTHED FOR 11KV
LV N – EARTHED THRU NER FOR 6KV
HV/LV N – SOLIDLY EARTHED ON
THE SECONDARY SIDE.
DISTRIBUTION TRANSFORMER
6/0.42 kV Class :
11/0.42 kV Class :
LV N SOLIDLY EARTHED
LV N SOLIDLY EARTHED
POWER TRANSFORMER
AGE-GROUP WISE POPULATION (NOS.) :
AGE-GROUP
132/33 kV
33/11-6 kV
0 to 5 Yrs.
4
18
5 to 10 Yrs.
2
18
4
10 to 15 Yrs.
9
37
2
15 to 20 Yrs.
2
20
20 to 25 Yrs.
5
12
25 to 30 Yrs.
1
6
30 to 35 Yrs.
2
5
35 to 40 Yrs.
2
4
40 to 50 Yrs.
6
9
50 to 60 Yrs.
31
> 60 Yrs.
9
6-11/0.4 kV
2
2
DISTRIBUTION
TRANSFORMERS
DISTRIBUTION
TRANSFORMERS
P/T :
O/T :
T/H :
2152 NOS.
2506 NOS.
1211 NOS.
DISTRIBUTION
TRANSFORMERS
PROTECTION :
HT ISOLATOR
HT CABLE BOX
HRC FUSE ON HT
HRC FUSE ON LT
DISTRIBUTION
TRANSFORMERS
AGE-GROUP WISE POPULATION :
TOTAL
(nos.)
5719
0-5
YRS.
5-10
YRS.
10-15
YRS.
15-20
YRS.
> 20
YRS.
(nos.)
(nos.)
(nos.)
(nos.)
(nos.)
1514
1199
1275
600
1131
SWITCHGEAR
SWITCHGEAR
POPULATION :
kV
Class
OUTDOOR
CB
INDOOR SWGR
(nos.)
GIS
(nos.)
132
80
15
33
115
27
6 & 11
AIS
(nos.)
COMPOUND / OIL
FILLED BUSBAR (nos.)
214
66
1037
323
SWITCHGEAR
INTERRUPTER :
VAC.
MOCB
BOCB
(nos.)
(nos.)
(nos.)
kV
Class
132
TOTAL
SF6
(nos.)
(nos.)
95
81
33
422
48
215
6
153
6 & 11
1360
458
463
50
389
14
SWITCHGEAR
OPERATING MECHANISM :
kV
TOTAL SPRING HYDRA PNEU SPRING SOLE
ULIC MATIC -PNEU
NOID
(nos.)
(nos.)
Class
(nos.)
(nos.)
(nos.)
MATIC
(nos.)
132
95
49
15
9
22
33
422
282
140
6 & 11
1360
1229
131
SWITCHGEAR
AGE-GROUP WISE POPULATION :
kV
TOTAL
(nos.)
Class
0-5
YRS.
5-10
YRS.
10-15
YRS.
15-20
YRS.
> 20
YRS.
(nos.)
(nos.)
(nos.)
(nos.)
(nos.)
132
95
11
26
40
8
10
33
422
84
54
72
53
159
6 & 11
1360
195
250
267
162
486
CAPACITOR BANK
CAPACITOR BANK
POPULATION & CAPACITY:
NO. OF
BANKS
COMMON
RATING
AGGREGATE
CAPACITY
132 kV
33 kV
11 kV
6 kV
2
13
6
56
50
MVAR
100
MVAR
15
MVAR
205
MVAR
4
MVAR
23
MVAR
4
MVAR
192
MVAR
CAPACITOR BANK
PROTECTION:
PROTECTION
132 kV 33 kV
ENCLOSED
NON-ENCL.
2
13
INTERNAL FUSE
2
8
EXTERNAL FUSE
5
11 kV
6 kV
6
27
29
6
40
16
CAPACITOR BANK
AGE-GROUP WISE POPULATION:
AGE-GROUP
0 - 5 YRS.
5 - 10 YRS.
10 - 15 YRS.
15 - 20 YRS.
20 - 25 YRS.
25 - 30 YRS.
30 - 35 YRS.
35 - 40 YRS.
132 kV 33 kV
2
8
2
1
1
1
11 kV
5
6 kV
14
6
1
12
5
3
5
6
5
BATTERY
BATTERY
RATING :
• FOR 132 kV SUBSTATIONS
200 - 250 Ah; 220 Volts
• FOR 33/11-6 kV DISTRIBUTION STNS.
40 Ah; 110 Volts
BATTERY
AGE-GROUP WISE POPULATION :
BATTERY
0 - 5 Yrs.
5 - 10 Yrs. 10 - 15 Yrs.
> 15 Yrs.
220
5
9
6
2
110
29
49
11
2