Why did We Develop this Tool?

Download Report

Transcript Why did We Develop this Tool?

ClimateMaster eQUEST (3.56)
An All-in-one Tool for Water Loop and
Ground Loop Heat Pump Systems
Design and Energy Analysis
Xiaobing Liu, Ph. D.
Why did We Develop this Tool?
•
•
•
•
Compare operating cost of WL/GL HP
system with other HVAC Systems
Size ground heat exchangers
Compute energy savings to get tax
credits and deductions
Make life easier
How did We do it?
1.
2.
Standing on
the shoulder
of giants
United we
stand
ClimateMaster
heat pump library
Advanced GLHE
modeling technology

eQUEST
•
•
•
•
DOE-2 derived engine
Building creation wizard
Industry standard input defaults
Graphical results display module
eQUEST 3.55 was approved by the California Energy
Commission as a 2001 Title 24 non-Residential ACM on
4/27/2005 (an eQUEST 2005 Title 24 non-Residential
ACM is being prepared but is not yet available.)
Advanced GLHE Model
•
•
•
•
•
G-function based algorithm
Account for various geometries of
borehole field
Account for grouting effect
Informative input guidance
Vertical ground loops only for now
ClimateMaster Heat Pump Library
•
•
•
•
•
•
•
•
•
Tranquility 27 – HFC410A, 2-stage
Tranquility 20 – HFC410A, 1-stage
Genesis GC – R22
Genesis GR – R22
Genesis GS – R22
Genesis GL – R22
VHS – R22, vertical stack
CCE – R22, console
RE – R22, rooftop
•
•
Information
Performance curves








TC=f(EWB, EFT)
SC=f(EWB, EFT)
HC=f(EDB, EFT)
EIR_C=f(EWB, EFT)
EIR_C =f(PLR)
EIR_H=f(EDB, EFT)
EIR_H =f(PLR)
BPF=f(EWB, EFT)
What are the Key Features?
•
•
•
•
Calculate hourly building loads
Simulate almost ALL HVAC systems
including WL/GL HP
Graphical reports
State-of-the-art tool
– First (only) to integrate the advanced GLHE
model with hourly building simulation
Example of System Comparison
•
•
•
Office building 25,000 ft2
Located at Oklahoma City
Compared HVAC systems
–
–
–
–
WLHP (tower and boiler)
Standard VAV with HW reheat
Four pipe fan coil
GLHP (vertical close loop GLHE)
Demonstration Process
•
•
•
Create building & HVAC system
Perform simulation
View results
– Energy consumption
– Peak demands
– Utility bill
•
Side-by-Side Comparison
Important Notes
•
Simulation creation wizards
– An expert advisor
– Systematic design wizards
– Design development wizards
•
Intelligent defaults
– Adopted from industry standards
– Dependent on prior selections
Start Demonstration
Side-by-Side Comparison
Comparison Results (1):
HVAC Related Energy Consumption [MBtu]
HVAC Energy Consumption
700
600
Gas [MBtu]
Elec [MBtu]
500
400
300
200
100
0
GLHP (GS
036)
WLHP (GS
036)
W_FPFC
(New Chiller)
W_VAV (New
Chiller)
Comparison Results (2):
Electricity and gas peak demands
120
1400
100
80
60
40
20
0
W_FPFC (New WLHP (GS 036) GLHP (GS 036)
Chiller)
W_VAV (New
Chiller)
Gas Peak Demand [kBtu/h]
Elec Peak Demand [kW]
140
1200
1000
800
600
400
200
0
GLHP (GS 036) WLHP (GS 036) W_FPFC (New
Chiller)
W_VAV (New
Chiller)
Comparison Results (3):
Annual Total Utility Bill
$8,000
Savings (Compared with W_VAV)
$7,000
Savings [$]
$6,000
$5,000
$4,000
$3,000
$2,000
$1,000
$0
W_VAV
(New
Chiller)
W_FPFC
(New
Chiller)
WLHP GLHP (GS
(GS 036)
036)
End Demonstration
What can We do Now?
•
•
•
Show customers the energy
savings from WL/GL HP
Help engineers size GLHE and
design WL/GL HP systems
Apply for LEED certification and tax
credits/deductions
Where to Get this Tool?
Register and download
ClimateMaster eQUEST (3.56) at
www.climatemaster.com
OR,
Download standard version of
eQUEST (3.56) at www.doe2.com
AND get additional features from us
What is the Difference?
Ordinary Users
eQUEST download
ClimateMaster
Customer download
42 pre-defined GLHE
configuration
308 pre-defined plus
unlimited customized
GLHE configurations
One set of WL/GL HP
performance curves
Complete library for all
ClimateMaster water-to-air
heat pump
Let’s Work Together
•
•
•
•
Improve building energy efficiency
Reduce dependence on imported energy
Reduce greenhouse gas emission
Sell more WSHP systems = more profits for all of us