features/programming

Download Report

Transcript features/programming

LuxPro
Thermostats
NEW
MULTI-STAGE
TOUCHSCREENS
Features & Programming
Mt. Laurel, NJ
LuxPro
Thermostats
NEW
MULTI-STAGE TOUCHSCREENS
• PSPU721T – 2H/1C
• PSPU732T – 3H/2C
• 7 Day Programmable OR
Non Programmable (Simple Mode)
• Dual Fuel Capable w/optional
Outdoor Wireless Remote Temp
Transmitter.
• Manual or Auto Humidity and DeHumidity Control (PSPU732T only)
• Installer Message
• Energy Watch – Calculates Usage
and Dollar Amount.
• Screen Lockout
• Much, Much, Much More…..
Mt. Laurel, NJ
VERY COMPETITIVE PRICING
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
TOUCH
FOR SIMPLE
THERMOSTAT
Mt. Laurel, NJ
• On power up, to use the
PSPU721 or 732 as a simple
non programmable thermostat,
touch the screen.
• To switch from programmable
mode to simple mode, remove
the faceplate, press & release
the reset button on the bottom
right. When “Touch For Simple
Thermostat” comes up on the
screen touch the screen and
the t-stat will switch to “Simple”
mode.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
46%
AUTO
FAN
AUTO
72F
-
Mt. Laurel, NJ
72.0
+
• Simple Mode puts the
thermostat into non
programmable mode
where only temperature
set point, cool/heat/auto
mode, or fan operation
can be changed.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
TOUCH FOR
PROGRAMMABLE
THERMOSTAT
Mt. Laurel, NJ
• For Programmable
Mode, touch the screen.
Now you can use all of
the extensive
programmable features
to configure the
thermostat the way you
or the consumer wants
it.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
• Home screen shows
temp set points, date,
time, room temp,
Mode
Setting
humidity, and outdoor
temp if using optional
Fan Setting
wireless temp
transmitter.
Heat Set Current time & date Cool Set
Point
Point
• Touch the Screen
anywhere to advance
to Control Screen.
* With Use of Wireless Remote Transmitter
Run
Program Outdoor Temp*
or Hold
Mt. Laurel, NJ
Room
Humidity
NEW TOUCHSCREEN
LuxPro
Thermostats
FEATURES/PROGRAMMING
Run
Program
or Hold
Auto, Cool
Heat, Emerg
Heat or Off
Fan Auto, Fan
Intermittent or
Fan On.
Auto or Installers Home
Manual Message Screen
RUN
PROG
HUMIDITY
MANUAL
AUTO
FAN
AUTO
MENU
HEAT
COOL
Main
Programming
Current
Mode
Blinks
Mt. Laurel, NJ
Current
46% room
temp &
humidity
70.0
DHUM
-
• The Control Screen is for
the consumer to
45
68.0
72.0
+
+
Adjust temp and •
dehumidification
settings
– make Temp changes,
– set Humidity to Auto or
Manual,
– set Dehumidifcation
– set Fan mode
– put t-stat in Hold or Run
Mode
– access Installers Message.
Press Home Screen
button to go back to
Home Screen.
• Press MENU to go to
Main Programming
Screen.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
DATE / TIME
SETTINGS
ADVANCED
SETTINGS
PROGRAM
SETTINGS
VACATION
SETTINGS
ENERGY
WATCH
FILTER
MONITOR
CLEAN
SCREEN
Mt. Laurel, NJ
SET
SCREEN
DEHUMIDIFY
• Main Menu
Programming Screen
allows owner to make
adjustments, settings
and programming
choices.
• Push Date / Time
Settings
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
DATE / TIME
SETTINGS
12
24
CLOCK
SET TIME / DATE
MENU
Mt. Laurel, NJ
12
33
PM H M
07
20
08
H D Y
• Set date & time by
pressing each button
individually.
• Press MENU to go
back to Main
Programming Screen
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
DATE / TIME
SETTINGS
ADVANCED
SETTINGS
PROGRAM
SETTINGS
VACATION
SETTINGS
ENERGY
WATCH
FILTER
MONITOR
CLEAN
SCREEN
Mt. Laurel, NJ
SET
SCREEN
DEHUMIDIFY
• Push “Program
Settings” to set
daily temperature
and fan settings.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
PROGRAM
SETTINGS
MO TU WE TH FR SA SU
MENU
Mt. Laurel, NJ
EVENT
1
FAN
AUTO
START
07
30
-
68.0
72.0
HEAT
COOL
AM
+
• Press day of week
• 4 on/off periods per day.
• Each day can be
programmed differently.
• Fan can be set differently
for each period.
• Each day can be copied
to the next.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
PROGRAM
SETTINGS
COPY MONDAY
SETTINGS
YES
Mt. Laurel, NJ
NO
• After completing each day’s
program, when you push the
next day, the user is asked if
they want to copy to the next
day.
• If YES, then you will continue
to the following day and be
asked the question again, etc.
• If NO, then you program that
day as you wish and proceed
on to all the days of the week.
• Press MENU when complete
to go back to the Main
Programming Screen.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
DATE / TIME
SETTINGS
ADVANCED
SETTINGS
PROGRAM
SETTINGS
VACATION
SETTINGS
ENERGY
WATCH
FILTER
MONITOR
CLEAN
SCREEN
Mt. Laurel, NJ
SET
SCREEN
DEHUMIDIFY
• Push “Energy
Watch” to see
HVAC energy
consumption and
cost to date.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
ENERGY
WATCH
RESET
MENU
Mt. Laurel, NJ
LAST 30 DAYS
150 HRS COMP.
20 HRS FURN.
120 HRS FAN
290 HRS TOTAL
COST
$20.30
• Energy Watch shows
energy consumption
for up to 255 days
based on parameters
set in “Advanced
Settings”.
• Owner can see
energy usage and
cost at anytime.
• Hit the RESET button
to zero out.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
CLEAN
SCREEN
DATE / TIME
SETTINGS
ADVANCED
SETTINGS
PROGRAM
SETTINGS
VACATION
SETTINGS
ENERGY
WATCH
FILTER
MONITOR
CLEAN
SCREEN
SET
SCREEN
DEHUMIDIFY
• By touching the
Clean Screen
button, you freeze
the screen for 15
seconds so that
you can wash/wipe
it w/o changing any
settings.
Consult owners manual for maintenance & care
Mt. Laurel, NJ
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
DATE / TIME
SETTINGS
ADVANCED
SETTINGS
PROGRAM
SETTINGS
VACATION
SETTINGS
ENERGY
WATCH
FILTER
MONITOR
CLEAN
SCREEN
Mt. Laurel, NJ
SET
SCREEN
DEHUMIDIFY
• Push “Set Screen”
to change screen
settings.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
SET SCREEN
BACKLIGHT
REVERSE
AUTO
ON
NIGHT REVERSE ON
MENU
Mt. Laurel, NJ
CONTRAST
07
• Backlight – Can be set to
Constant Light or Auto
(touch the screen).
• Reverse – Change from
B/W to W/B.
• Night Reverse - Set for
Auto screen reverse
(chgs at 9PM and 6AM).
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
DATE / TIME
SETTINGS
ADVANCED
SETTINGS
PROGRAM
SETTINGS
VACATION
SETTINGS
ENERGY
WATCH
FILTER
MONITOR
CLEAN
SCREEN
Mt. Laurel, NJ
SET
SCREEN
DEHUMIDIFY
• Push “Vacation
Settings” to set
parameters for
time & temperature
while away from
the home.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
VACATION
SETTINGS
VACATION SETTINGS
BEGIN
09
20
08
END
09
30
08
HEAT
COOL
Mt. Laurel, NJ
-
65.0
80.0
+
• Input leave
(BEGIN) date,
return (END)
date and
heat/cool temp
settings.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
DATE / TIME
SETTINGS
ADVANCED
SETTINGS
PROGRAM
SETTINGS
VACATION
SETTINGS
ENERGY
WATCH
FILTER
MONITOR
CLEAN
SCREEN
Mt. Laurel, NJ
SET
SCREEN
DEHUMIDIFY
• Push “Filter
Monitor” to see
filter usage in days
and to reset after
changing filter.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
FILTER
MONITOR
FILTER
USED 15 DAYS
RESET
MENU
Mt. Laurel, NJ
• Filter Monitor
Screen shows how
many days current
filter has been used
(based on fan run
time).
• Reset button will
set back to zero.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
HUMIDITY
SETTINGS
DATE / TIME
SETTINGS
ADVANCED
SETTINGS
PROGRAM
SETTINGS
VACATION
SETTINGS
ENERGY
WATCH
FILTER
MONITOR
CLEAN
SCREEN
SET
SCREEN
DEHUMIDIFY
• Push this button to
toggle between
“Humidify” or
“Dehumidify” mode.
• More detailed
settings for humidity
control are available
in Advanced Settings.
(Installer settings)
Mt. Laurel, NJ
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
ADVANCED
SETTINGS
DATE / TIME
SETTINGS
ADVANCED
SETTINGS
PROGRAM
SETTINGS
VACATION
SETTINGS
ENERGY
WATCH
FILTER
MONITOR
CLEAN
SCREEN
SET
SCREEN
DEHUMIDIFY
• Push & hold the Advanced
Settings button for 5 seconds
and the installer will be
allowed to make additional
and more detailed program
settings.
• The following screen will
appear when entering
Advanced Settings:
CAUTION: Altering the system properties in
the ADVANCED SETTINGS may affect the
performance of the HVAC system and should
be performed only by a qualified installer.
Mt. Laurel, NJ
NEW TOUCHSCREEN
LuxPro
Thermostats
FEATURES/PROGRAMMING
• Advanced Settings
Screen allows installer to
set:
ADVANCED
SETTINGS
DAYLIGHT TIME
NEXT
PAGE
MENU
FILTER
ENERGY
WATCH
SECURITY
INSTALL
MESSAGE
F
OFF
–
–
–
–
–
–
Daylight Savings On/Off
Filter Days
Energy Usage Parameters
Celsius or Fahrenheit
Security level
Installers message
• Press FILTER to set
Filter Monitor to Off/On &
number of days to
monitor.
Mt. Laurel, NJ
LuxPro
Thermostats
ADVANCED
SETTINGS
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
FILTER
MONITOR
FILTER MONITOR
OFF
MENU
Mt. Laurel, NJ
• Turn Filter Monitor
Off or ON.
• An icon appears on
the Home Screen
when the Filter
monitor is set to ON.
LuxPro
Thermostats
NEW TOUCHSCREEN
ADVANCED
SETTINGS
FEATURES/PROGRAMMING
FILTER
MONITOR
CHANGE FILTER
AFTER
MENU
2
MONTH
• When you turn THE
Filter Monitor ON,
screen will then ask for
the number of months
(up to 6), based on fan
run time, to notify
consumer to change
filter.
Return to Advanced
Settings Screen
Mt. Laurel, NJ
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
ADVANCED
SETTINGS
DAYLIGHT TIME
NEXT
PAGE
MENU
Mt. Laurel, NJ
FILTER
ENERGY
WATCH
SECURITY
INSTALL
MESSAGE
F
OFF
• Push “Energy
Watch” to set
parameters for
tracking HVAC
energy usage
and cost.
LuxPro
Thermostats
NEW TOUCHSCREEN
ADVANCED
SETTINGS
FEATURES/PROGRAMMING
ENERGY
WATCH
MENU
5
COMPRESSOR KW
5
FURNACE KW
1
FAN KW
13
C / KWHr
• Set consumption KW
parameters for
compressor, furnace &
fan, and per hr KW
cost.
• This allows consumer
to watch on going
HVAC energy costs by
pushing the “Energy
Watch” button on the
Main Menu Screen.
Return to Advanced
Settings Screen
Mt. Laurel, NJ
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
ADVANCED
SETTINGS
DAYLIGHT TIME
NEXT
PAGE
MENU
Mt. Laurel, NJ
FILTER
ENERGY
WATCH
SECURITY
INSTALL
MESSAGE
F
OFF
• Push “Security”
to set level of
screen lock
preferred.
LuxPro
Thermostats
ADVANCED
SETTINGS
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
SECURITY
SECURITY
OFF
CHANGE PIN
MENU
Mt. Laurel, NJ
FULL LOCK
• To turn Security on to
FULL Lock or PARTIAL
Lock, push OFF button.
• You will be asked for a
Pin #. The default Pin #
is 1111.
• To change your Pin #
push Change Pin and
follow the prompts.
LuxPro
Thermostats
ADVANCED
SETTINGS
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
SECURITY
SECURITY
OFF
CHANGE PIN
MENU
FULL LOCK
• Push the Lock button to
toggle between FULL
Lock and PARTIAL Lock
• FULL Lock completely
locks out the thermostat
from unauthorized use
w/o the Pin #
• PARTIAL Lock only allows
the changing of the
temperature setpoint.
Return to Advanced
Settings Screen
Mt. Laurel, NJ
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
ADVANCED
SETTINGS
DAYLIGHT TIME
NEXT
PAGE
MENU
Mt. Laurel, NJ
FILTER
ENERGY
WATCH
SECURITY
INSTALL
MESSAGE
F
OFF
• Push “Install
Message” to
input installer
message and set
frequency of
display.
LuxPro
Thermostats
ADVANCED
SETTINGS
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
INSTALL
MESSAGE
For Service Call ABC Htg
at 777-555-4321
1
2
3
4
5
ABC DEF GHI JKL MNO
0
6
7
8
9
:/PQR STU VWX YZ
MENU
Mt. Laurel, NJ
OK
• Message of up to 42
characters.
• Message can be
programmed to appear
on a monthly basis.
• Message can also be
accessed by consumer
by pushing the
icon
button on the Control
Screen.
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
ADVANCED
SETTINGS
DAYLIGHT TIME
NEXT
PAGE
MENU
Mt. Laurel, NJ
FILTER
ENERGY
WATCH
SECURITY
INSTALL
MESSAGE
F
OFF
• Push “Next Page”
to access
Advanced settings
for system type,
cycles rates,
staging temps, dual
fuel, humidity and
more…
NEW TOUCHSCREEN
ADVANCED
SETTINGS
FEATURES/PROGRAMMING
• Heat Pump
• 2 Stg HP
• A/C
• No Compressor
NEXT
PAGE
LuxPro
Thermostats
• Electric Furnace
• Gas Furnace
• 2 Stg Gas Furn.
• Oil Furnace
HEAT
PUMP
9
CYCLE
RATE
ELECTRIC
FURNACE
3
AUTO
CHNGE
PREV
PAGE
HP CUT OFF
MENU
CUT TEMP
ON
+
40
• Select type of HVAC
system.
• Set Max Compressor
Cycle Rate per Hr.
(2 - 9)*
• Auto Change is
minimum temp (dead
band) difference
between Heat/Cool
set points. (1 – 5 )*
* factory settings are recommended
PUSH NEXT FOR FURTHER SETTING
Mt. Laurel, NJ
LuxPro
Thermostats
NEW TOUCHSCREEN
ADVANCED
SETTINGS
FEATURES/PROGRAMMING
DUAL
FUEL
NEXT
PAGE
Mt. Laurel, NJ
HEAT
PUMP
9
CYCLE
RATE
ELECTRIC
FURNACE
3
AUTO
CHNGE
PREV
PAGE
HP CUT OFF
MENU
CUT TEMP
ON
+
36
• Heat Pump Cut Off is for
Dual Fuel applications.
By turning the HP CUT
OFF to ON, and setting
the CUT TEMP
(outside), the HP will
shut down at that CUT
TEMP and the gas
furnace will take over.
• Press NEXT PAGE for
further settings
LuxPro
Thermostats
NEW TOUCHSCREEN
ADVANCED
SETTINGS
FEATURES/PROGRAMMING
DUAL
FUEL
HP
NEXT
PAGE
PREV
PAGE
MENU
Mt. Laurel, NJ
OFF
WHEN
FURNACE ON
• Allows heat pump to
operate with the
furnace by changing
to the ON position.
• Press NEXT PAGE
for further settings
LuxPro
Thermostats
NEW TOUCHSCREEN
ADVANCED
SETTINGS
MULTI-STAGE
DIFFERENTIAL
SETTINGS
FEATURES/PROGRAMMING
1ST STAGE DIF
2
NEXT
PAGE
2ND STAGE DIF
2
PREV
PAGE
3RD STAGE DIF
2
MENU
OB ENERGIZED
COOL
• 1st Stage Differential is the
temp difference from set
point that the heat or cool
initiates.
• 2nd Stage Differential is the
temp difference from 1st stg
set point & 2nd stg start-up.
• 3rd Stage…
• Set the reversing valve to
energize in Heat or Cool
depending on unit design
Consult equipment manufacturer’s operation/installation
manuals before setting these temperature settings.
Mt. Laurel, NJ
PUSH NEXT FOR FURTHER SETTING
LuxPro
Thermostats
NEW TOUCHSCREEN
ADVANCED
SETTINGS
FEATURES/PROGRAMMING
MULTI-STAGE
DIFFERENTIAL
SETTINGS
IF STAGE 1 RUNS
NEXT
PAGE
PREV
PAGE
MENU
0
MINUTES
TURN ON STAGE 2
• This time setting brings on
2nd stage (heat or cool) if
system has not been able
to reach the 2nd stage
temperature setpoint.
• This avoids excessive
compressor run time by
bringing on the 2nd stage
and full system capacity to
meet setpoint.
Consult equipment manufacturer’s operation/installation
manuals before setting these temperature settings.
Mt. Laurel, NJ
PUSH NEXT FOR FURTHER SETTING
LuxPro
Thermostats
ADVANCED
SETTINGS
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
HUMIDITY
CONTROL
Mt. Laurel, NJ
HUM FAN
OFF
NEXT
PAGE
DH FAN
OFF
PREV
PAGE
DH REVERSE
OFF
MENU
DHCONTCOMP
OFF
• Humidity Fan – When
set to ON the fan will
run when there is an
independent call to
humidify. When set to
OFF, fan only runs
during heating or
cooling cycles.
• De-Humidity Fan –
Same as above.
LuxPro
Thermostats
NEW TOUCHSCREEN
ADVANCED
SETTINGS
FEATURES/PROGRAMMING
HUMIDITY
CONTROL
Mt. Laurel, NJ
HUM FAN
OFF
NEXT
PAGE
DH FAN
OFF
PREV
PAGE
DH REVERSE
OFF
MENU
DHCONTCOMP
OFF
• DH REVERSE:
• ON - DH relay is
normally closed when
relative humidity is
above DH set point.
• OFF - DH relay is
normally open when
relative humidity is
below DH set point.
LuxPro
Thermostats
NEW TOUCHSCREEN
ADVANCED
SETTINGS
FEATURES/PROGRAMMING
HUMIDITY
CONTROL
Mt. Laurel, NJ
HUM FAN
OFF
NEXT
PAGE
DH FAN
OFF
PREV
PAGE
DH REVERSE
OFF
MENU
DHCONTCOMP
OFF
• DH CONTROL
COMPRESSOR:
• ON - Thermostat will turn off
the air conditioning if either
the dehumidify set point or
the temperature set point is
reached, whichever comes
first, both DH relay and
compressor will turn off.
• OFF - DH relay is
independent of compressor
activity (DH becomes a spare
relay and can be used for a
variable speed fan or
separate dehumidifier or air
exchanger)
LuxPro
Thermostats
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
ADVANCED
SETTINGS
+
TEMP +
HUM
PREV
PAGE
MENU
Mt. Laurel, NJ
0
0
0
• This screen allows you
to calibrate temperature
or relative humidity if
found to be off.
• Temperature accuracy is
set at +/-1 degree. It can
be adjusted +/- 9.5.
• Humidity accuracy is +/4%. It can be adjusted
+/- 20%.
• Press NEXT PAGE for
further settings
NEW TOUCHSCREEN
LuxPro
Thermostats
FEATURES/PROGRAMMING
De-humidification options for
increasing comfort and efficiency
• HRV/ERV units can be controlled by simply
connecting the DH terminal on the
thermostat to the terminal DH of the
HRV/ERV. Most HRV/ERV units will control
properly with the DH REVERSE feature
turned off (contact normally open).
• OPTION 1: In Advanced Settings choose
DH ControlComp, set to ON then lower the
temperature to a minimum safe set point,
then set the desired de-humidity level. Dehumidify will control the compressor (unless
minimum temperature set point is reached)
whichever comes first.
Mt. Laurel, NJ
NEW TOUCHSCREEN
LuxPro
Thermostats
FEATURES/PROGRAMMING
De-humidification options for
increasing comfort and efficiency
• OPTION 2: Connect terminal DH to
Y1 and set thermostat to de-humidify
mode. Then regardless of
temperature the de-humidification
setting will have priority. Caution: This
method will run the compressor until
the de-humidification level is reached
and may cause overcooling.
Mt. Laurel, NJ
NEW TOUCHSCREEN
LuxPro
Thermostats
FEATURES/PROGRAMMING
De-humidification options for
increasing comfort and efficiency
• OPTION 3: Connect the DH
terminal to a variable speed fan
control, (set DH REVERSE to
control the fan so that low speed
is activated to de-humidify). This
method provides maximum
comfort while maintaining the
temperature in cooling mode.
Mt. Laurel, NJ
LuxPro
Thermostats
NEW TOUCHSCREEN
Wireless Remote Temp Transmitter
Mounting Bracket
• Optional Wireless Remote
Outdoor Temperature
Transmitter for PSPU7 multistage touchscreens. Used for
DUAL FUEL & AUTOMATIC
HUMIDITY CONTROL of
central humidifier.
Indoor Receiver
(plugs in at bottom of t-stat
and mounts under t-stat
cover)
Optional Outdoor
Wireless Remote
Temp Transmitter Kit
#WTR064
Mt. Laurel, NJ
NEW TOUCHSCREEN
LuxPro
Thermostats
Wireless Remote Indoor Receiver
PSPU Thermostat Screen
Plug antenna wire from
Indoor Receiver into
plug located at bottom
right of PSPU t-stat
Plug Indoor Receiver
into plug located at
bottom of PSPU t-stat
Mt. Laurel, NJ
Push Reset button on
Indoor Receiver to initiate
communication between
Outdoor transmitter and
Inside Receiver.
Indoor Receiver
Unit installed
LuxPro
Thermostats
WIRING LEGEND
12
11
RC
TERMINAL
Y1
G
W2
OBW
RH
Y2
C
H
DH
RC
11 and 12
Mt. Laurel, NJ
DH
H
C
Y2
RH
OBW
W2
G
Y1
EQUIPMENT
STANDARD COLOR
First Heat Pump
Yellow
and/or AC
Fan
Green
First Stage Furnace
White
Reverse Valve or
Orange
Second Stage Furnace
24v Heat Transformer
Red
Second Heat Pump
Unknown
and/or AC
Common
Blue
Humidity Control
Unknown
Dehumidify Control
Unknown
Variable Fan Control
24v Cool Transformer
Unknown
Not Used
NOTE: The above colors are standard in HVAC industry. The wiring
should be confirmed before installation
LuxPro
Thermostats
TECHNICAL
SUPPORT
• For more information, tech
sheets, submittals, please refer to
the Instruction or Engineering
Manuals, or access the LuxPro
web site at
www.luxproproducts.com.
• Problems with installation or
troubleshooting, please call our
Technical Support team at (856)
234-8803 Ext. 7 (5:30AM – 2PM PST)
It is best if contractor is on jobsite when calling Tech Support
Mt. Laurel, NJ
LuxPro ’s Full line oF LuxPro
Thermostats
Residential & light Comm’l
Thermostats offer you the
best VALUE.
Thanks for viewing our
Touchscreen Presentation
Mt. Laurel, NJ