Burndy-Grounding
Download
Report
Transcript Burndy-Grounding
GROUNDING 101
GROUNDING 101
WHY DO WE GROUND?
SAFETY
Protect
People
Protect
Equipment from
Fault Currents
Grounding 101 – Summer 2007 - TS
3
WHY SHOULD WE GROUND?
Electricity will always follow the
path of least resistance to ground.
Proper circuit grounding will keep electricity from using your
body to get to ground
Grounded Circuit Requirements:
• Path is continuous and permanent
• Ample capacity
• Low Resistance
• Circuit parts are bonded together
Grounding 101 – Summer 2007 - TS
4
WHAT DO WE GAIN?
Provides
personnel safety - #1 priority
Provides
a stable signal reference for
instrument accuracy
Controls
Radio Frequency emissions &
Electromagnetic Interferences (EMI’s)
Provides
a discharge path for short
circuits and lightning strikes
Grounding 101 – Summer 2007 - TS
5
LIGHTNING PROTECTION
LIGHTNING
FACTS
Packs between 35,000 and 40,000 amperes
Generates temperatures as high as 50,000 C
Travels as far as 40 miles
Strikes somewhere on the earth every second
Kills 100 people each year in the U.S.A.
Destroys millions of dollars in property and equipment
Grounding 101 – Summer 2007 - TS
6
STATIC DISCHARGE
THE
Grounding 101 – Summer 2007 - TS
7
UNWANTED SPARK
Grounding Locations
Example: TEL-COM CELL SITE
Grounding 101 – Summer 2007 - TS
8
BURNDY HAS THREE TYPES
OF GROUNDING PRODUCTS
MECHANICAL
COMPRESSION
EXOTHERMIC
(weld)
Grounding 101 – Summer 2007 - TS
9
MECHANICAL
Grounding 101 – Summer 2007 - TS
10
WHAT IS A MECHANICAL CONNECTOR?
Makes a secure connection using bolts or other hardware to bind
conductors in place.
Grounding 101 – Summer 2007 - TS
11
Range Taking
No special tooling
Inexpensive
Removable
WHAT ARE THE MOST
COMMON CONNECTORS?
Grounding 101 – Summer 2007 - TS
12
CONNECTOR CATEGORIES
BUS
BAR / FLAT BAR
GB
Cable to bar
with separator
Grounding 101 – Summer 2007 - TS
GBM
Cable directly to bar
13
GZ
Cable to bar loop
CONNECTOR CATEGORIES
BUS
BAR / FLAT BAR
GL
GCM
QGFL
Two parallel
cables / tap
GC
Two Cables
directly to bar
Grounding 101 – Summer 2007 - TS
Two cable to bar
with separator
14
Eye in basket
CONNECTOR CATEGORIES
BUS
BAR / FLAT BAR
GKA
Grounding 101 – Summer 2007 - TS
KPB
15
KC
Servit post
CONNECTOR CATEGORIES
FENCE
POST, PIPE & TUBING
GK
GP
GAR
Three cable parallel
GD
Two cable
Perpendicular
Grounding 101 – Summer 2007 - TS
Two cable parallel
16
Cable to rod
CONNECTOR CATEGORIES
FENCE
POST, PIPE & TUBING
GAR-TC
GG
Cable or
braid to rod
Grounding 101 – Summer 2007 - TS
KC
Servit post
17
Cable at 45
90 degrees
CONNECTOR CATEGORIES
FENCE
POST, PIPE & TUBING
Lower cost clamps
GC-A
Duel rated
pipe clamps
Grounding 101 – Summer 2007 - TS
18
CONNECTOR CATEGORIES
GROUND
RODS / REBAR
GRC
GAR
GP
Ground Rod Clamp
Two cable
perpendicular
Cable to rod
Grounding 101 – Summer 2007 - TS
19
GK
Three cable parallel
CONNECTOR CATEGORIES
STATIC
GIE
GROUND
Vehicle or
temporary ground
Grounding 101 – Summer 2007 - TS
GP-G1
Raised flooring
20
GRF
Raised flooring
CONNECTOR CATEGORIES
CABLE
& BRAID
Braid
Spans movable
areas
GG
GX
Cable or
braid to rod
KA
Cross
connection
Grounding 101 – Summer 2007 - TS
Tap to run
21
CONNECTOR CATEGORIES
TRANSFORMER
RAIL
& BEAM
KC
J&RGC
Servit post
GA-H
Cable to H
beam or tube
Grounding 101 – Summer 2007 - TS
22
QGFL
Eye in basket
HIGHLIGHTS: SPLIT BOLTS
KS25
AVAILABLE FROM
#2 TO 500 kcmil
UL Listed for
direct burial
Grounding 101 – Summer 2007 - TS
23
HIGHLIGHTS: Parts of a Split Bolt
Grounding 101 – Summer 2007 - TS
24
HIGHLIGHTS: Dual Rated Split Bolts
Used
for any combination of copper and aluminum
conductors.
Grounding 101 – Summer 2007 - TS
25
JOINING COPPER AND ALUMINUM
Grounding 101 – Summer 2007 - TS
26
RAISED FOOR GROUNDING
RAISED
FLOOR GROUND GRIDS
Grounding 101 – Summer 2007 - TS
27
GRF CLAMP ON RAISED FLOOR
Grounding 101 – Summer 2007 - TS
28
Can be used on round
or square pedestals
Accommodates one or
two grounding wires
GP-G1 / GP-RT FOR RAISED FLOOR
Epoxy paint penetrating
Can be used on round or square pedestals
Accommodates one or two grounding wires
Grounding 101 – Summer 2007 - TS
29
QUESTION:
WHEN
IS A MECHANICAL
CONNECTOR NOT ACCEPTABLE?
ANSWER:
When a permanent connection is called out,
or
When connection is exposed to severe
conditions such as extreme vibration
Grounding 101 – Summer 2007 - TS
30
MECHANICAL
QUESTIONS?
Grounding 101 – Summer 2007 - TS
31
BURNDYWELD
Grounding 101 – Summer 2007 - TS
32
BURNDYWELD
USES
AN EXOTHERMIC
PROCESS TO JOIN
COPPER
PROVIDES
A SOLID
COPPER IRREVERSIBLE
BOND
WILL
NOT LOOSEN OR
CORRODE AT THE WELD
Grounding 101 – Summer 2007 - TS
33
EXOTHERMIC PROCESS
The
exothermic process is a simple, efficient method of
welding copper to copper or copper to steel.
This
process uses a high temperature reaction of
powdered copper oxide and aluminum.
Reaction
Mold
takes place in a graphite mold.
will last for 50 or more welds with proper care.
This
system is very field friendly, since it is light and
portable and requires no outside power.
Grounding 101 – Summer 2007 - TS
34
THE SEQUENCE OF STEPS
MOLD
Grounding 101 – Summer 2007 - TS
35
Open mold using
handle clamp, and
insert the conductors
as desired
Insert steel disc into the
mold cavity
Pour powdered metal
into the mold cavity
Close the lid
Tap powder container
to add the starting
powder to ignition
pocket
Use flint device to
ignite
Brush and remove mold
1.
2.
3.
4.
5.
6.
Grounding 101 – Summer 2007 - TS
36
SIX STEPS FOR
A PERFECT
BURNDYWELD
OVER 57 DIFFERENT MOLDS
CABLE TO CABLE
WELD TO REBAR
Grounding 101 – Summer 2007 - TS
37
MOLDS
MOUNT TO FLAT OR ROUND SURFACE
Grounding 101 – Summer 2007 - TS
38
SINGLE SHOTS
PROVIDES
THE SAME WELD RESULT IN A COST
EFFECTIVE, ONE TIME USE PACKAGE
Grounding 101 – Summer 2007 - TS
39
WELD
QUALITY
What do
you look
for?
Grounding 101 – Summer 2007 - TS
40
WELD QUALITY
Many
factors contribute to the weld success
Grounding 101 – Summer 2007 - TS
41
WELD INSPECTION
HOW DO YOU TEST THE
INTEGRITY OF A WELD IN
THE FIELD?
Grounding 101 – Summer 2007 - TS
42
COMMON PROBLEMS
WITH EXOTHERMIC
WELDING
Moisture
Worn
molds
Unclean
conductors
Unclean
mold
Mistakes
made in
welding process
Grounding 101 – Summer 2007 - TS
43
ANY
QUESTIONS ON
BURNDYWELD?
Grounding 101 – Summer 2007 - TS
44
COMPRESSION
Grounding 101 – Summer 2007 - TS
45
COMPRESSION THEORY
CREATION
Grounding 101 – Summer 2007 - TS
OF A HOMOGENEOUS MASS
46
HY-GROUND SYSTEM
Grounding 101 – Summer 2007 - TS
47
COMPRESSION
»Range Taking
»Permanent
»Safe to install
»Quick and Easy
BURNDY HAS DEVELOPED AN IRREVERSIBLE COMPRESSION
GROUND SYSTEM WHICH MEETS THE STRINGENT SAFETY AND
PREFORMANCE REQUIREMENTS UL AND IEEE.
CONNECTORS EMPLOY WELL PROVEN DESIGN PRINCIPLES
AND TECHNOLOGY THAT HAVE BEEN IN EXISTENCE FOR OVER
60 YEARS.
Grounding 101 – Summer 2007 - TS
48
COMMON APPLICATIONS
Where
HY-GROUND is used
Grounding 101 – Summer 2007 - TS
49
GRID LAY OUT
Grounding 101 – Summer 2007 - TS
50
COMPONENTS OF HY-GROUND
WHAT’S
NEEDED
Proper Connector
Correct Crimping Tool
Specified Die
Grounding 101 – Summer 2007 - TS
51
CONNECTORS
IRREVERSIBLE
RATED
MANY
CONNECTION
FOR DIRECT BURIAL
COMPONENTS AVAILABLE
Grounding 101 – Summer 2007 - TS
52
MEETS REQUIREMENTS
UNDERWRITERS
NATIONAL
IEEE
LAB TESTS
ELECTRICAL CODE
837 REQUIREMENTS
UL96
LISTED FOR LIGHTNING
PROTECTION
CANADA
STANDARDS ASSOCIATION
APPROVED
Grounding 101 – Summer 2007 - TS
FOR DIRECT BURIAL
53
UL LISTINGS
Rigorous
testing in the Burndy UL facilities ensures all
product exceed standards.
Grounding 101 – Summer 2007 - TS
54
SUPERIOR CONNECTION
PRE-FILLED
WITH PENETROX OXIDE-INHIBITOR
Superior connection
Grounding 101 – Summer 2007 - TS
55
PENETROX E FILLED
Air
SHOWS
Penetrox
VERY FEW CONTACT POINTS
Fills The Gaps For Better Contact
Grounding 101 – Summer 2007 - TS
56
Gaps
EASY TO INSPECT
DIE
INDEX EMBOSSMENT.
Match embossed number to the number
listed the on connector.
Grounding 101 – Summer 2007 - TS
57
INSTALLS IN ANY ENVIRONMENT
Installs
In Wet Environments
Grounding 101 – Summer 2007 - TS
58
COMMON TYPES - HY-GROUND
YGLR-C
YGHC-C
Ground rod to grid
Figure C
YGL-C
Cross connection
YGHP-C
Figure 6
Grounding 101 – Summer 2007 - TS
59
COMMON TYPES - HY-GROUND
YGHP-C
YGHR-C
H-Tap
Ground rod or tap
Wire third hand
YGIB
Figure 8
Crimp to structure
Grounding 101 – Summer 2007 - TS
60
Splice or tap
COMMON TYPES - HY-GROUND
YGHS HGS
YGHA
GSTUD-HY
YGF
Splice- heavy duty / standard
Hylug
Versitail weld on
Grounding plate
Grounding 101 – Summer 2007 - TS
61
FINDING THE PROPER CONNECTOR
YGHC-C
Grounding 101 – Summer 2007 - TS
62
FINDING THE PROPER CONNECTOR
Grounding 101 – Summer 2007 - TS
63
HY-GROUND CRIMPING TOOLS
Y750HS
PAT750XP
18V
PATRIOT 18VOLT
Y46
HY-PRESS
REMOTE HEAD
Grounding 101 – Summer 2007 - TS
64
FINDING THE PROPER DIE
INSTALLATION DATA
DIE
INDEX
NUMBER
Y750/Y35
Y39
1
Y45
2
Y46
NUMBER
OF
HYPRESS CRIMPS
HYPRESS
HYPRESS
C
U-C
U-C
U-C
1
O
U-O
U-O
U-O
1
Installation Data Listed in Catalog
Grounding 101 – Summer 2007 - TS
65
ANY
QUESTIONS ON
COMPRESSION?
Grounding 101 – Summer 2007 - TS
66
WHERE DO YOU USE THE
THREE TYPES OF GROUNDING
PRODUCTS?
MECHANICAL
COMPRESSION
EXOTHERMIC
(weld)
Grounding 101 – Summer 2007 - TS
67
CONNECTION APPLICATIONS
TEL-COM
TOWER
Grounding 101 – Summer 2007 - TS
68
CONNECTION APPLICATIONS
CENTRAL
Grounding 101 – Summer 2007 - TS
OFFICE SITE
69
DIFFERENT WIRE TYPES
ALWAYS
KNOW THE SIZE AND TYPE OF WIRE YOU ARE
CRIMPING
Grounding 101 – Summer 2007 - TS
70
WIRE GAGE
KEEP A
WIRE MIKE HANDY FOR WIRE IDENTIFICATION
Grounding 101 – Summer 2007 - TS
71
AVOID CORROSION
USE PENETROX-E
OXIDE INHIBITOR
ON COPPER
CONNECTIONS
Grounding 101 – Summer 2007 - TS
72
THANKS FOR CONSIDERING BURNDY PRODUCTS
PLEASE
CONTACT US IF YOU HAVE ANY QUESTIONS
OR PRODUCT NEEDS.
TECHNICAL
SERVICE (800) 451-4956
NEVER LET LIFE BE A SHOCK TO YOU!
Grounding 101 – Summer 2007 - TS
73