GeN2 Regen - Otis Elevator Company
Download
Report
Transcript GeN2 Regen - Otis Elevator Company
GeN2 Regen
Duty Table
Rated Speed
(m/s)
Load (Kg)
630
680
800
1000
1150
1275
1350
1.00
50m/16F
1.50/1.60
75m/24F
1.75
75m/24F
Max. group control: G8C
1600
1/66
1800
2000
GeN2 Regen
Space saving, energy saving, environmental friendly and excellent ride quality
Gen2 Machine
(MOR)
Shenling Governor
CSB
NGSOK
Regen Drive
Controller
2/66
AES/AMS
GeN2 Regen
OTIS unique technology- Coated Steel Belt (CSB)
20% less in weight while 2-3 times life time
Lubrication free
Size: 30×3 & 60x3
Steel cords: 12 & 24
3/66
Cord diameter 1.67mm
Technology from helicopter (Sikorsky)
Breaking load: 32KN & 64KN
GeN2 Regen
CSB makes GeN2 Regen machine much smaller
Roped Machine
Gen2 Machine
Diameter of sheave:100mm
Diameter of sheave:115mm
Groove:3/5
Groove:5
Brake voltage:24V
Brake voltage:24V
Insulation class: F
Insulation class: F
4/66
GeN2 Regen
CSB Monitor
CSB monitor (RBI)
– Resistance Based Inspection (RBI) for CSB
– Dynamic inspection of CSB status
– LED indication
– Elevator level at nearest floor when failure inspected
– REM interface
– A component, not a tool
5/66
GeN2 Regen
OTIS GECB Controller board
Motorola 32 bit CPU with 1M Flash memory.
Rear time failure clinic automatically
CAN BUS 2.0 communication
CE Comply
ESD to avoid jobsite damage
Up to100 floors and 4m/s
ESD: Electro-Static discharge
6/66
GeN2 Regen
ACD2 MRL Controller and Drive
OTIS energy regenerative drive
CAN-bus communication
Mini E&I Panel
Drive
E&I Panel
210W x 540H x 90D
Controller
7/66 320W x1300H x 160D
GeN2 Regen
Regen
Principle
Regenerative
system
Energy saving
Up to
+
OTIS Regenerative Drive
OTIS Gen2 Machine
8/66
GeN2 Regen
NGSOK Door operator
Key parameters:
Center Opening
700
800
900
1000
1100
1200
Open Time(s)
2.2
2.3
2.5
2.9
3.3
3.7
Close Time(s)
2.4
2.5
2.7
3.1
3.5
3.9
• PM motor, energy saving
Re-open Distance(mm)
100
• VVVF controller
Open/Close noise(dBA)
52 (Peak)
• Motor drive directly, no gearbox
Re-open noise(dBA)
55 (Peak)
• Disc motor, space saving
• Easier for installation
–
Side opening is availble OP=900~1300
–
Standard opening height:2100/2000
• Max. moving mass: 200kg
• Motor IP: 44
9/66
For Gen2 Regen and also for all other passenger elevators
Safety Components
GeN2 Regen
E3 Qualified
Safety Gear
Speed governor
– Otis US design qualification
– Otis US MFG process control
– Otis US change control
– Reliable
– Durable
– Traceability
Oil buffer
Comparison
Component
OTIS E3 Requirements
Safety Gear
25 freefall and runaway test
Speed Governor
25 Continuous tripping
Buffer
100 strike test
EN81-1 Requirements
4 freefall test
20 Continuous tripping
10/66
6 strike test
GeN2 Regen
Excellent Performance Data
Gen2 Regen
Traditional lift
(Belted, gearless)
(Roped geared)
X- Vibration A95 (mg)
≤9
≤ 11
Y- Vibration A95 (mg)
≤9
≤ 11
Z- Vibration A95 (mg)
≤ 11
≤ 14
Speed Tolerance (%)
(@+10%VRate, +1%fRate, Tmax 40℃)
+3
+5
Maximum Acceleration( m/s2)
(@ start and stop)
1.2
1.2
Maximum Jerk ( m/s3)
(@ running)
1.0
1.0
Noise (dB)
(@ Machine room)
≤ 72
≤ 75
Noise (dB)
(@ In car, w/o fan, running )
≤ 53
≤ 53
Typical: ±3
Max. : ±5
±5
System performance
Level accuracy (mm)
(@+7%VRate, +1%fRate, Tmax 40℃)
11/66