Bio-Cascade, Inc Clean Air and Water Systems

Download Report

Transcript Bio-Cascade, Inc Clean Air and Water Systems

Bio-Cascade, Inc
Clean Air and Water Systems©
Distributors of
Clean Air Plant (CAP©)
and Clean Water Plant (CWP©)
For Air and Water Solutions, Nutley, NJ
Air & Water Solutions History
• 1996 - Introduction of CAP Clean Air
Plant for control of indoor air quality
(IAQ), World’s 1st (and only) Biological
IAQ Control System
• 2002 Business Achievement Award,
Technology Merit Award for biological air
and water cleaning systems for industry,
Environmental Business Journal
Page 2 of 20
Air & Water Solutions Background
•Dr. Sam Sofer PhD, PE; Principal
engineer of the bio-hygienic
products offered by the company
•Nutley, New Jersey; Company
headquarters, manufacturing
operations and technical research
center
Page 3 of 20
How CAP/CWP works
Biological Oxidation
• Living organisms obtain energy by
oxidation reactions.
• Humans and animals consume food
therefore capturing the energy from the
food source and reducing it to carbon
dioxide,water and solids.
Page 4 of 20
Biological Oxidation (continued)
•Biological Oxidation is a natural reaction where
micro-organisms capture the energy in an organic
substance (food source) and use it for the
oxidation process.
•This allows biological oxidation to take place
without a large increase in temperature or energy
usage. The results of this are CO2, water and inert
bio-solids.
•As contaminants come in contact with microorganisms, they are biologically oxidized to CO2
and water. Heavy metals and solids are
consolidated and rendered harmless.
Source: www.cleanairplant.com
Page 5 of 20
Bio-hygienics
(bi'o-hi jen'ikx); The application of compact treatment plants utilizing bio-oxidation for
indoor and outdoor applications
•Contaminants and odors that are persistent
travel on particulates.
•Most large particles will travel with air flow and
can be vented.
•Small particles, the ones which are most
harmful, are resistant to normal air flow and
cannot be vented.
•These particulates are electrically charged.
•Their motion is controlled by electrical fields not
by air flow.
•For these reasons, many odors linger even
Page 6 of 20
when an area is exhausted.
Bio-hygienics (continued)
• CAP© neutralize contaminants in the air and
creates an electrically neutral “clean zone.”
• Contaminants, both positively and negatively
charged, are attracted to this neutral clean
zone, where they are captured in the unit and
biologically oxidized.
• CWP© work the same way, creating a clean
water zone. Contaminants move to the clean
zone, are drawn into the unit, where they are
biologically oxidized.
Page 7 of 20
Substantial cost savings
• Superior technology to
– Carbon - substantially more economical
– Thermal destruction
• First bio-oxidizer designed for indoor applications
• Miniaturized plants save energy and space
• Single technology, single solution
• Very low maintenance
• Can be installed modularly to meet growing demands
• Bio-hygienics offers the benefits of immobilized cell
technology in a compact treatment plant that is fast,effective
and economical.
• Advances in bio-hygienics address air and water quality,
nuisance odor issues and industrial waste management in a
complete, economical solution for companies large and small.
• CAPs and CWPs are the only bio-systems that address air
and water contaminants bio-hygienically.
Page 8 of 20
Machine Operation
• The CAP™ Machine is can be modified to fit
both stationary and portable applications.
• The size of the machine is based on both area
covered and amount of pollution present
• Portable applications: It is recommended the
machine be in operation in the area prior to
activity related to targeted pollution
Page 9 of 20
CAP™/CWP™
• BioOX© is the Bio-Enzyme microbial media
used to consume pollution.
• Start up recommendations and amount used
during normal operation are based on machine
and application. (Chart to come later in
presentation).
• The more pollution ,the more BioOx needed.
• Many applications will need less BioOx the
longer the machine has been operating as it will
clean the air and built up pollution in walls,
ceiling tiles and ventilation systems.
Page 10 of 20
CAP™ requirements for normal operation
• Dual outlet power supply to run pump and fan.
• Water must be added as needed(daily in most
cases). Automatic water feed can be installed
on larger machines.
• Heaters can be added for exterior applications
to prevent water freeze.
• BioOx added monthly or more frequently as
needed.
Page 11 of 20
CAP™ 5000
Trash Transfer Station Applications
CAP 5000 with Rodent Intake
Guards
Page 12 of 20
CAP™ 90
•Can be made
portable
•Will cover up to
3,000 sq.ft.
•10 lbs. of pollution
per day
Page 13 of 20
CAP™ 600
• Covers areas
over 5,000 sq.ft.
• Destroys up to
60 lbs. of
pollution per
day
• Interior and
exterior
applications
Page 14 of 20
Compare Indoor Air Cleaners
Technology Evaluation Table for Indoor Air Cleaners
Type Cleaner
Gases
VOC’S
Ozone

Ionizer

UV

Particulates
Bio-Hygienics


HEPA
(all air filters)
Carbon
Canister


CAP


Safety




Page 15 of 20
CAP™ Machine Specifications
Model
Equiv.
Flow
Rate
(cfm)
Pollution
Destruction
(lbs/day)*
NEW CAP-50
500
5
NEW CAP-75
520
NEW CAP-80
CAP-90
Industrial
Model
BioOx®
Usage
Size & Weight
(US) Power
Consumption
Area Model
Cleans
Typical
Application
8 oz startup
2 oz/week for 2 mos.
Thereafter 2 oz/month
12” sq x 15”
18 lbs
30 W
Up to 800 ft2
Room, office
7
8 oz startup
4 oz/week for 2 mos.
Thereafter 4 oz/month
12” sq x 20”
20 lbs
30 W
Up to 1500 ft2
Small house,
office
1000
10
16 oz startup
4 oz/week for 2 mos.
Thereafter 4 oz/month
12” sq x 24”
25 lbs
30 W
Up to 2000 ft2
Medium office,
garage, shop,
salon,
schoolroom
1000
10
16 oz startup
4 oz/week for 2 mos.
Thereafter 4 oz/month
15” sq x 32”
35 lbs
40 W
Up to 3000 ft2
Office, plant,
garage,
commercial &
small industry
Page 16 of 20
CAP™ Machine Specifications (continued)
Model
CAP-600
CAP-2500
CAP-5000
CAP-X
Series (all
models
above)
Equiv.
Flow
Rate
(cfm)
Pollution
Destruction
(lbs/day)*
BioOx®
Usage
Size & Weight
(US) Power
Consumption
7500
60
1 gal. startup
16 oz/week for 2
mos.
Thereafter 16
oz/month
30” dia x 48”
26” at base
200 lbs
175 W
12500
19400
250
500
Area Model Cleans
Units designed to
handle commercial
and industrial areas
2 gal. startup
48 oz/week for 2
mos.
Thereafter 48
oz/month
36” dia x 50”
+ 12-24” fan
housing
300 lbs
438 W
3 gal. startup
½ gal./week for 2
mos.
Thereafter 64
oz/month
52” dia x 50”
+ 12-24” fan
housing
500 lbs
500 W
of 5000 ft2 and
larger, with heavy
pollution load
Typical
Application
Small-medium
industry, plant,
warehouse, lab,
loading dock,
restaurant, bar,
hotel, parking
garage
Industry, plant,
terminal,
indoor/outdoor,
heavy pollution
All environments.
Specifically designed
for extremely
concentrated and
toxic air
contaminants
Concentrated
discharges from
mixers, reactors
and other similar
equipment
Page 17 of 20
CWP™ Machine Specifications
Equiv.
Flow
Rate
(gpm)
Pollution
Destruction
(lbs/day)*
BioOx®
Usage
Size & Weight
(US) Power
Consumption
Area Model
Cleans
Typical
Application
CWP-100
2
10
4 oz./mo.
Startup: 16 oz. Then 4
oz/week for 2 mos.
12” sq x 20”
30 lbs
Small,
compact and
portable
For sinks, fish
tanks, ponds.
Small space
applications
CWP-175
20
40
16 oz/mo.
Startup: 32 oz. Then 8
oz/week for 2 mos.
12” sq x 20”
20 lbs
30 W
CWP-SVE
20-50
60
16 oz/mo.
Startup: 1 gal. Then 16
oz/week for 2 mos.
30” dia x 8”
100 lbs
Model
Small-scale
industry,
industrial
wastewater,
waste tank
contents, fuelcontaminated
home sumps
or direct
treatment of
ground water
Saves on
carbon costs
For industrial
applications,
fish tanks,
wells, ponds,
small lakes.
Page 18 of 20
CWP™ Machine Specifications (cont.)
Model
CWP-1000
CWP-2500
CWP-5000
CWP-25000
Equiv.
Flow
Rate
(gpm)
Pollution
Destruction
(lbs/day)*
BioOx®
Usage
Size & Weight
(US) Power
Consumption
50
100
24 oz./mo.
Startup: 1 gal.
Then 24 oz/week for 2
mos.
36” dia x 48”
250 lbs.
48 oz./mo.
Startup: 2 gal.
Then 48 oz/week for 2
mos.
36” dia x 50”
250 lbs.
64 oz./mo.
Startup: 3 gal.
Then ½ gal./week for 2
mos.
52” dia x 50”
350 lbs.
50-100
100200
100500
250
500
2500
2.5 gal./mo.
Startup: 10gal.
Then 1 gal./week for 2
mos.
Area Model
Cleans
Cleans large
amounts of
Typical
Application
Wastewater,
chemical
waste streams,
waste tank
liquid.
Designed for
sudden
contents.
Large volume
streams or
surface water
runoff.
increase in
72” dia x 84”
600 lbs.
flow.
Direct
treatment of
groundwater.
Page 19 of 20
For more information
or to contact us: