Introduction to EVM
•
•
•
•
•
It is a reliable machine for conducting Elections.
Has mainly 2 units: Ballot and Control Units.
Operates on a Special Battery
Tamper-proof
Information recorded is retained in memory even
when the battery is removed.
• Manufactured by Electronics Corporation of India &
Bharat Electronics Ltd. and approved by Election
Commission, India.
• Easily portable
Units
• Each Unit has been provided a casing.
• Once opened 3 things will be found: Control
unit, Ballot Unit and the Interconnecting
Cable.
Control Unit
Ballot Unit
Cable
Battery
• They are Special batteries supplied separately
• These batteries have a Seal which should be
removed before Using
• They have an active lifetime of 24 hours.
Details of Interconnecting Cable
• It is a flat protected cable and who’s one end is connected to
the Ballot Unit permanently while the other end is attached
VIA a connector to the Control unit.
• Make sure that the cable is properly secured to the Control
unit.
Cable
TOP
15 PIN CONNECTOR
SPRING CLIPS
2. Control Unit
• Controls the polling process.
• Operated only by P.O.
• Consists of:
ON lamp
4 sections in
all
Busy lamp
Display
Section
Candidate Set
Section
Result Section
Ballot Section
Details of Control Unit
• Display section has: 2 lamps: On and Busy ; also 2 display
panels: one of 2 digit and other of 4 digit displays.
• Candidate Set Section: has a cover opening l-r: we see a left
compartment which accommodates the Battery and the right one
a Red Cad Set button. This section is closed by thread Seal.
• Result Section: also has same cover as above. On opening we find
the left side has a Black Close button while right side has inner
compartment with its own door. One button her is result 1
button. used for one type of election only: like only single Poll.
Result 2 used for both types conducted at the same time, Clear
button. Provision kept for a seal in the cover of this inner compt.
and thread seal too.
• Ballot Section: has 2 buttons , a gray Total button and a large
Ballot button.
• Bottom of C.Unit also open for plugging the cable from b.unit and
a power switch to switch EVM On/Off.
Lamps details….
• On lamp: in display section will glow GREEN when
Control Unit Power switch is put ON, indicating EVM
is ready for use.
• Busy lamp: in display section glows RED when Ballot
button is pressed by P.O. to enable voter to cast vote.
Goes Off when over.
ERROR
Indicates the Control Unit is not fit for use
INVALID Indicates a button on the Control Unit has been
pressed out of sequence.
CU ERROR Indicates the Control Unit is to be changed.
BU – 1 ERROR
Indicates the Ballot Unit-1 is to be changed
CLOCK ERROR
Indicates the malfunction of Real Time Clock (RTC)
Display Panel details
2 DIGIT DISPLAY
• LE: link error: ie. Interconnecting cable not
properly connected.
• PE: Pressed error, where any of the candidates
buttons in Ballot unit are jammed or kept
pressed.
• Er: Memory Error: Control unit not fit to use.
Display Panel details
4 DIGIT DISPLAY
• no: indicates a button pressed on Control unit
is pressed out of sequence.
• End: End of display sequence after pressing
Close , Result or clear button.
• Full : indicates max no.of votes for which
machine is designed. 9999 is the max.
Display on both panels
•
•
•
•
nP 1 : machine set for Single poll only.
Cd 6 : machine set for 6 candidates.
to 1234: total no. of votes casted = 1234
06 234: candidate 6 has 234 votes in his favor.
Beeps
• A beep of not less than 2 seconds after a voter
casted his vote.
• A beep of 1 second, when displaying
information on display units.
• Short interrupted beeps to show
malfunctioning , disconnection, errors….
• Ballot: enables voter to record his vote: so once
pressed: the BUSY lamp goes Red, Ready
lamp of C.Unit goes Green and voter can now
caste his vote. Then Pressed again to allow
next voter to record his vote….
• Total: shows no. of candidates and total no. of
votes recorded so far. Pressed at anytime: to
see the same. But not when Busy lamp is ON.
• Close: Once pressed: no further voting can
take place. Only pressed at the end of the Poll.
When Pressed the no. of polls, no. of
candidates, total votes polled and the word
end will be displayed
Display Panel details
2 DIGIT DISPLAY
• LE: link error: ie. Interconnecting cable not
properly connected.
• PE: Pressed error, where any of the candidates
buttons in Ballot unit are jammed or kept
pressed.
• Er: Memory Error: Control unit not fit to use.
Display Panel details
4 DIGIT DISPLAY
• no: indicates a button pressed on Control unit
is pressed out of sequence.
• End: End of display sequence after pressing
Close , Result or clear button.
• Full : indicates max no.of votes for which
machine is designed. 9999 is the max.
Display on both panels
•
•
•
•
nP 1 : machine set for Single poll only.
Cd 6 : machine set for 6 candidates.
to 1234: total no. of votes casted = 1234
06 234: candidate 6 has 234 votes in his favor.
Beeps
• A beep of not less than 2 seconds after a voter
casted his vote.
• A beep of 1 second, when displaying
information on display units.
• Short interrupted beeps to show
malfunctioning , disconnection, errors….
• .
• Ballot: enables voter to record his vote: so once pressed: the BUSY
lamp goes Red, Ready lamp of C.Unit goes Green and voter can
now caste his vote. Then Pressed again to allow next voter to
record his vote….
• Total: shows no. of candidates and total no. of votes recorded so far.
Pressed at anytime: to see the same. But not when Busy lamp is
ON.
• Close: Once pressed: no further voting can take place. Only pressed
at the end of the Poll. When Pressed the no. of polls, no. of
candidates, total votes polled and the word end will be displayed.
• .
+NOTA
Main Source:-www.eci.nic.in. &
Miss.KenyirOlga Nongrum, NIC
for Election Dept.Jowai Although some
modifications has been done keeping in view
the aspects of Training.
This PPT must only be used for
Non-Commercial
Purpose.