How to Calculate Your Emissions

Download Report

Transcript How to Calculate Your Emissions

PM
How to Calculate Your Emissions
2014 Emissions Inventory Workshop
General Equation
For most emission sources the following equation is used:
E = A * EF
Where
E = Calculated emissions
A = Activity or annual process rate
EF = Emission factor - determined by the method of calculation
Example sources:
• AP-42
• WebFire
• Permit
Process:
10-100 mmbtu/hr boiler
SCC:
10200602
Fuel:
Natural Gas
Capacity:
84 mmbtu/hr
Control:
Uncontrolled
US EPA CHIEF Website: http://www.epa.gov/ttn/chief/index.html
2014 Emissions Inventory Workshop
2014 Emissions Inventory Workshop
5
2014 Emissions Inventory Workshop
6
2014 Emissions Inventory Workshop
7
2014 Emissions Inventory Workshop
8
E = A * EF = ??? tons
E
A
EF
84 lbs
CO = 673 mmscf ∗
= 56,532 lbs
mmscf
Convert to tons:
ton
CO = 56,532 lbs ∗
= 28.266 tons
2,000 lbs
Process:
2 - Cycle Lean Burn Natural Gas Engine
SCC:
20200252
Fuel:
Natural Gas
Capacity:
1100 hp
Control:
Uncontrolled
US EPA CHIEF Website: http://www.epa.gov/ttn/chief/index.html
2014 Emissions Inventory Workshop
2014 Emissions Inventory Workshop
14
2014 Emissions Inventory Workshop
15
2014 Emissions Inventory Workshop
16
2014 Emissions Inventory Workshop
17
2014 Emissions Inventory Workshop
18
E = A * EF = ??? tons
E
A
EF
0.0552 lbs
Formaldehyde = 47000 mmBTU ∗
= 2,594 lbs
mmBTU
Convert to tons:
ton
= 1.297 tons
Formaldehyde = 2,594 lbs ∗
2,000 lbs
Process:
Reciprocating emergency generator
SCC:
20200102
Fuel:
Diesel
Capacity:
400 hp
Pollutant:
NOx
Factor:
604 lbs/1000 gal
Control:
Uncontrolled
Operation:
50 hours
Activity:
500 gal
Heat Content:
137 mmbtu/1000 gal
E = A * EF = ??? tons
E
A
EF
604 lbs
NOx = 500 gal ∗
= 302 lbs
1000 gal
Convert to tons:
ton
NOx = 302 lbs ∗
= 0.151 tons
2,000 lbs
Process:
Surface coating – spray painting
SCC:
40200101
Pollutant:
Xylene, VOC (non-HAP)
Paint:
Acrylic Red
2014 Emissions Inventory Workshop
24
E = A * VOC Content * (Xylene:VOC Ratio) = ??? tons
8.75 lbs
Total VOC = 800 gal ∗
= 7,000 lbs = 3.5 tons
gal
0.08
Xylene = 3.5 tons ∗
= 1.12 tons
0.25
Now, for non-HAP VOC:
VOC (non-HAP) = Total VOC ̶ Xylene
VOC (non-HAP) = 3.5 tons − 1.12 tons = 2.38 tons
Process:
Pneumatic Controllers: High Bleed
SCC:
31000242
Pollutant:
VOC
Bleed Rate:
32.1 scf/hr whole gas
E = Gas Vented * VOC Content = ??? tons
Gas vented =
Bleed rate ∗ Hours ∗ Devices
32.1 𝑠𝑐𝑓
Gas vented = 5 devices ∗
1 hr
∗ 8760 hr = 1406 Mscf
VOC = Gas Vented ∗ Gas MW∗ wt. % VOC ∗ Conversion
𝑙𝑏
VOC = 1406 Mscf ∗ 19.25 𝑙𝑏∙𝑚𝑜𝑙 ∗ 0.13 % VOC ∗
VOC Emissions = 9,284 lb ∗
1 𝑡𝑜𝑛
2,000 lb
1 𝑙𝑏∙𝑚𝑜𝑙
379 𝑠𝑐𝑓
= 9,284 lb
= 4.642 tons VOC
Capture Efficiency:
The percentage of air emission that is collected and
routed to the control equipment. Most control
devices have a 100% capture efficiency.
Control Efficiency:
The percentage of air pollutant that is removed from
the air stream by the control device.
Process:
Primary Crushing
SCC:
30532001
Pollutant:
PM10
Control:
Water Spraying
E = A * EF * (1 – Control Efficiency) = ??? tons
E
A
EF
0.0024 lbs
PM 10 =1,361,120 tons ∗
= 3,267 lbs
ton
Account for control:
PM 10 = 3,267 lbs ∗ 1 − 0.777
Convert to tons:
ton
PM 10 = 729 lbs ∗
2,000 lbs
= 729 lbs
= 0.36 tons
Process:
Grain handling for feed manufacture
SCC:
30200801
Activity:
10,000 tons
Pollutant:
PM 10
Factor:
3 lbs/ton
Primary Control:
Cyclone
Secondary Control:
Baghouse
A Complex Situation: Capture Efficiency,
Primary Efficiency & Secondary Efficiency
2014 Emissions Inventory Workshop
34
Capture Device: Hood
Capture Efficiency (CE) = 90% = 0.90
Therefore, the other 10% is emitted directly to the atmosphere
Primary control device: Cyclone
• The control equipment removes 80% of PM 10 from the emission stream.
Primary Efficiency (PE) = 80% = 0.80
Secondary control device: Baghouse
• The control equipment removes 98% of PM 10 from the emission stream.
Secondary Efficiency (SE) = 98% = 0.98
Total E = Captured E + Uncaptured E = ??? tons
Captured E = A * EF * CE * (1 – PE) * (1 – SE)
Uncaptured E = A * EF * (1 – CE)
Captured E = A * EF * CE * (1 – PE) * (1 – SE)
A
EF
3 lbs
PM 10 = 10,000 tons ∗
= 30,000 lbs
ton
Account for capture and controls:
CE
Captured PM 10 = 30,000 lbs ∗ 0.90 = 27,000 lbs
PE
SE
PM 10 = 27,000 lbs ∗ 1 − 0.80 ∗ 1 − 0.98 = 108 lbs
Uncaptured E = E * (1 – CE)
Uncaptured PM 10 = 30,000 lbs ∗ (1 − 0.90) = 3,000 lbs
Account for all PM 10 emissions:
Total PM 10 = Captured PM 10 + Uncaptured PM 10
Total PM 10 = 108 lbs + 3,000 lbs = 3,108 lbs
Convert to tons:
ton
Total PM 10 = 3,108 lbs ∗
= 1.554 tons
2,000 lbs
1
30,000 lbs of
PM generated
4
2
3,000 lbs of PM
emitted “not captured”
5
3
Amount to Hopper
27,000 lbs* 0.80 = 21,600 lbs
27,000 lbs– 21,600 lbs =
5,400 lbs to the Baghouse
27,000 lbs of
PM “captured” ,
sent to cyclone
2014 Emissions Inventory Workshop
6
Amount to Hopper
5,400 lbs * 0.98 = 5,292 lbs
7
Amount emitted to the atmosphere
5,400 lbs – 5,292 lbs = 108 lbs
108 lbs stack emissions + 3,000 lbs
“not captured,” emitted as a fugitive =
3,108 lbs = 1.554 tons
39
If you would like to see an example calculation for
another industry, process, or control equipment not
presented today:
Please email [email protected] and we will create an
example for you.
Program Manager:
Mark Gibbs
[email protected]
Emissions Inventory Staff:
Cooper Garbe
[email protected]
Cody Lathrop
[email protected]
Michelle Horn
[email protected]
Justin Milton
[email protected]
Carrie Schroeder
[email protected]
http://www.deq.state.ok.us/aqdnew/emissions/index.htm