Gilian_5000_Intro_and_Operation

Download Report

Transcript Gilian_5000_Intro_and_Operation

New Gilian 5000

5 LPM Air Sampling Pump

Gilian 5000 Features

• • • • • • • Our most powerful 5 LPM pump Digital flow display with 30-day calibration Meets EN 1232 requirements Intrinsically safe Fast charge, 4 hours or less Memory free NiMH battery pack Intuitive 4-key operation

Wide Flow Rate Range

• 1000 to 5000 cc/min, constant flow • 20 to 750 cc/min with LFCP adapter • Digital Flow Display

Intuitive Keypad Operation

• • • Easy operation No tools, 4-key format Similar to Gilian 3500

Highest Back Pressure Specs

• • • • • 5000 cc/min…..…….to 20 inches H2O 4000 cc/min………...to 30 inches H2O 3000 cc/min…………to 50 inches H2O 2000 cc/min…………to 60 inches H2O 1000 c/min…………..to 70 inches H2O

Compare at 2 LPM

• • • • • Gilian 5000 Gilian 3500 GilAir-3 GilAir-5 HFS-513 • • • • • 60 inches H2O 35 inches H2O 20 inches H2O* 37 inches H2O 40 inches H2O • * GilAir-3 spec is 20 inches at 2.5 LPM

Compare Also at 2 LPM

• • • • • • • Gilian 5000 Casella APEX Pro SKC 224-44XR SKC AirChek XR 5000 MSA Escort Elf TSI SP-350 Buck VSS-5 • • • • • • • 60 inches H2O 31.5 inches H2O 40 inches H2O 50 inches H2O 30 inches H2O 29 inches H2O 60 inches H2O

Compare at 5 LPM

• • • • • Gilian 5000 GilAir-5 HFS-513 SKC 224-44XR SKC AirChek XR 5000 • • Casella APEX Pro Buck VSS-5 • • • • • • • 20 inches H2O 10 inches H2O 15 inches H2O N/A 10 inches H2O Free flow 2 inches H2O

Operation of the Gilian 5000

Power Up/Ready Mode

Taking a Sample

Key Pad Lock-out

Setting the Flow Rate

Displayed Flow Calibration

Calibration Set Up

Low Flow Sampling

• • • • Set Flow Rate at 1500 cc/min Attach adapter with arrow pointing toward the pump Can be attached in-line or fixed mount Use holder with needle valve for constant pressure/multi-flow sampling

Calibration Using Low Flow

Gilian 5000 Programmability

• • • • Start-Stop Programmable through Set/Cal key Up to four events of varying duration Can also program a duty cycle for extended time sampling Can also activate and deactivate certain functions like auto re-start and instant start.

Programming

• • • • • • • The Program Mode is accessed by pressing the set/Cal key three times.

A program is activated by pressing the up arrow to display a “1” To create a new program press Enter, and enter values for the following parameters 1) A delayed start 2) Up to four run times of various duration 3) Up to four delay-run times to determine holds between runs 4) Number of cycles

Options

• • • • • Options are accessed by pressing the Set/Cal key four times to display OPT Three Options may be activated by pressing the UP arrow to display a “1” 1) Disable auto re-start 2) Enable auto lock 3) Enable auto start (by-passes the Ready mode)

Gilian 5000 Our most powerful personal sampling pump from the world leader.